Med-Fit MED-FIT 1

Brugermanual til Med-Fit 1 dobbeltkanals TENS-maskine

Model: MED-FIT 1

Indledning

This manual provides instructions for the safe and effective use of your Med-Fit 1 Dual Channel TENS Machine. Please read all instructions carefully before operating the device and retain this manual for future reference.

The Med-Fit 1 TENS machine is designed to provide temporary relief from pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arm), and lower extremities (leg) due to strain from exercise or normal household and work activities.

Pakkens indhold

Når du åbner pakken, skal du kontrollere, at alle komponenter er til stede:

  • Med-Fit 1 dobbeltkanals TENS-maskine
  • Self-adhesive electrode pads (multiple pairs)
  • Lead wires (2 sets)
  • 2 AA batterier (medfølger)
  • Instruktionsmanual
Med-Fit 1 TENS machine, packaging, electrode pads, and lead wires

Image: Med-Fit 1 TENS machine with its retail packaging, electrode pads, and lead wires. This image illustrates the complete set of items typically found in the product package.

Enhedsfunktioner

The Med-Fit 1 TENS machine is a dual-channel device with adjustable settings for pulse width, pulse rate, and intensity. It offers multiple modes for pain relief.

Diagram of Med-Fit 1 TENS machine with labeled components

Image: Diagram highlighting the key components of the Med-Fit 1 TENS machine, including lead connectors, intensity controls, mode selector, indicator lights, pulse width dial, and pulse rate dial.

  • Ledningsstik: Ports for connecting electrode lead wires.
  • Intensitetskontrol: Rotary dials to adjust the stimulation intensity for each channel.
  • Tilstandsvælger: Switch to select between different treatment modes (Constant, Modulation, Burst).
  • Indikatorlys: Visual indicators for device operation.
  • Pulse Width Dial: Adjusts the duration of each electrical pulse.
  • Pulse Rate Dial: Adjusts the number of electrical pulses per second.
  • Robust klips: Located on the back for attaching the device to clothing.

Opsætning og drift

1. Batteriinstallation

The device operates on 2 AA batteries. Ensure the batteries are correctly installed before use. Open the battery compartment on the back of the device, insert the 2 AA batteries, and close the compartment securely.

2. Tilslutningselektroder

  1. Connect the lead wires to the electrode pads. The electrode pads feature 2mm pin connectors.
  2. Plug the lead wires into the output jacks on the top of the TENS unit.
Close-up of electrode pads with 2mm pin connectors

Billede: Et nærbillede view of the self-adhesive electrode pads, showing the 2mm pin connectors and the multi-layer construction including hypoallergenic gel and conductive carbon.

3. Elektrodeplacering

Clean and dry the skin area where electrodes will be placed. Apply the self-adhesive electrode pads directly to the skin around the painful area. Ensure good contact for effective stimulation. Refer to the included electrode placement guide for common pain areas.

Electrode placement on a person's back for pain relief

Image: A person's back with four electrode pads strategically placed to target pain. This demonstrates a typical setup for back pain relief using the TENS machine.

Various electrode placements on different body parts

Image: A collage showing different electrode placements on various body parts, including the thigh, knee, and calf, illustrating how the TENS machine can be used for pain relief in multiple areas.

4. Valg af en tilstand

The Med-Fit 1 offers three primary modes for pain relief:

  • Konstant tilstand: Provides continuous electrical stimulation.
  • Modulationstilstand: Varies the pulse width and/or pulse rate to prevent adaptation.
  • Burst-tilstand: Delivers short bursts of high-frequency stimulation.

Use the mode selector switch to choose the desired treatment mode. Consult a healthcare professional for guidance on the most suitable mode for your condition.

5. Justering af indstillinger

Once the electrodes are in place and a mode is selected, slowly turn the intensity control dials clockwise to increase the stimulation. Adjust the pulse width and pulse rate dials as needed. Begin with low intensity and gradually increase until a comfortable, tingling sensation is felt. Avoid increasing intensity to a level that causes discomfort or muscle contraction.

Typical treatment sessions last 15-30 minutes, but duration may vary based on individual needs and professional advice.

Vedligeholdelse og pleje

  • Rengøring af enheden: Wipe the TENS unit with a soft, damp klud. Apparatet må ikke nedsænkes i vand, og der må ikke anvendes slibende rengøringsmidler.
  • Elektrodepleje: After each use, place the self-adhesive electrodes back on their protective liner. Store them in a sealed bag to prolong their lifespan. Replace electrodes when they lose their adhesiveness or become dry.
  • Opbevaring: Opbevar enheden og tilbehøret et køligt, tørt sted, væk fra direkte sollys og ekstreme temperaturer.
  • Udskiftning af batteri: Replace the 2 AA batteries when the device's performance diminishes or indicator lights dim.

Fejlfinding

ProblemMulig årsagLøsning
No sensation or weak stimulation
  • Lavt batteri
  • Electrodes not making good contact
  • Lead wires not properly connected
  • Intensiteten er for lav
  • Electrodes are dry or worn out
  • Udskift batteriet
  • Ensure electrodes are firmly pressed onto clean skin
  • Check all lead wire connections
  • Øg gradvist intensiteten
  • Udskift elektroderne
Skin irritation under electrodes
  • Electrodes left on too long
  • Skin not clean
  • Allergic reaction to electrode gel
  • Reduce treatment duration
  • Clean skin thoroughly before application
  • Discontinue use and consult a healthcare professional
Enheden tænder ikke
  • Batteri installeret forkert
  • Batteriet er dødt
  • Kontroller batteriets orientering
  • Udskift batteriet

Sikkerhedsoplysninger og advarsler

Important: Consult your doctor before using this device, especially if you have pre-existing medical conditions.

  • Må ikke anvendes, hvis du har en pacemaker, implanteret defibrillator eller anden implanteret metallisk eller elektronisk enhed.
  • Må ikke bruges, hvis du er gravid.
  • Do not use on areas of skin that are broken, irritated, or numb.
  • Do not use over the carotid sinus nerves (front of the neck), on the head, or over the eyes.
  • Opbevares utilgængeligt for børn.
  • Discontinue use if you experience any adverse reactions and consult a healthcare professional.
  • TENS is not a cure for pain, but a method for managing pain.
Healthcare professional recommending the TENS machine

Image: A healthcare professional giving a thumbs-up gesture next to the Med-Fit 1 TENS machine and electrode pads, indicating professional recommendation. Note: Not suitable for use in pregnancy.

Specifikationer

MærkeMed-Fit
ModelnummerMED-FIT 1
Dimensioner (L x B x H)4 x 2 x 10 cm
Vægt300 gram
Strømkilde2 AA batterier (medfølger)
KanalerDobbelt kanal
FabrikantHealthCentre

Garanti og support

For warranty information and customer support, please refer to the contact details provided with your purchase or visit the official Med-Fit webwebsted. Gem din købsbevis til garantikrav.

Relaterede dokumenter - MED-FIT 1

Preview Med-Fit Pebble TENS-terapienhed JPD-ES200 brugermanual
Omfattende brugermanual til Med-Fit Pebble TENS-terapiapparatet (model JPD-ES200), der beskriver funktioner, betjening, sikkerhedsforanstaltninger, TENS-programmer, vedligeholdelse og fejlfinding.
Preview Med-Fit R-C4A-RW1 Premier TENS-maskine brugermanual
Brugermanual og instruktioner til Med-Fit R-C4A-RW1 Premier Dual Channel TENS-maskinen, der giver vejledning om betjening, sikkerhed, programmer og specifikationer for smertelindring og muskelstimulering.
Preview Med-Fit trådløs 4-kanals TENS-maskine brugermanual og instruktioner
Omfattende brugermanual og instruktioner til Med-Fit trådløs 4-kanals TENS-maskine. Lær, hvordan du bruger denne bærbare enhed til midlertidig lindring af muskelsmerter. Indeholder sikkerhedsretningslinjer og tekniske specifikationer.
Preview Brugermanual til Med-Fit trådløs 2-kanals TENS-maskine
Brugermanual til Med-Fit trådløs 2-kanals TENS-maskine, der beskriver sikker betjening, smertelindring og vedligeholdelse. Inkluderer kontraindikationer og fejlfinding.
Preview Brugervejledning til Premier Easy TENS og muskelstimulatorer
En omfattende brugervejledning til Premier Easy TENS og muskelstimulatorer, model EM6300P. Denne vejledning indeholder detaljerede instruktioner om kontroller, funktioner, programmer, placering af elektroder og sikkerhedsforanstaltninger for både TENS- og EMS-tilstande.
Preview Brugermanual til Med-Fit Pebble TENS-terapiapparat
Brugermanual til Med-Fit Pebble Dual Channel TENS-terapiapparatet (model: JPD-ES200), der indeholder instruktioner om brug, sikkerhed, specifikationer og fejlfinding.