1. Introduktion
This manual provides essential information for the proper installation, operation, and maintenance of the Pentair Air Relief Tube, model 150040. This component is specifically designed for use with Pentair Triton II TR50 and TR60 pool and spa sand filters manufactured after November 1999. Adhering to these instructions will help ensure the longevity and optimal performance of your pool filtration system.
2. Produktet er slutview
The Pentair Air Relief Tube 150040 is a critical component in the air relief system of compatible Pentair sand filters. Its primary function is to allow trapped air to escape from the filter tank during startup and operation, preventing air pockets that can impede water flow and reduce filtration efficiency. This tube measures approximately 18 inches in length and has a diameter of 1/4 inch.

An image showing the black, flexible Pentair Air Relief Tube, model 150040, designed for pool and spa sand filters.
3. Sikkerhedsoplysninger
Always observe basic safety precautions when installing or servicing pool equipment. Failure to do so could result in serious injury or property damage.
- Afbryd strømmen: Always turn off the main power to the pool pump and filter system at the circuit breaker before performing any service or maintenance.
- Trykaflast systemet: Ensure the filter system is completely depressurized before opening any valves or removing components. Open the air relief valve on top of the filter until all pressure is released.
- Læs instruktionerne: Familiarize yourself with the entire filter system's manual before attempting any repairs or replacements.
- Brug de rigtige værktøjer: Use appropriate tools for the task to prevent damage to components or injury.
4. Opsætning og installation
This section outlines the general procedure for replacing an existing air relief tube. Refer to your specific Pentair Triton II filter manual for detailed diagrams and component locations.
Nødvendige værktøjer:
- Screwdriver (if applicable for filter clamp)
- Pliers or wrench (if applicable for fittings)
Installationstrin:
- Forbered systemet: Turn off the pool pump and disconnect power at the circuit breaker. Open the manual air relief valve on the filter to release all internal pressure.
- Drain Filter (if necessary): If the filter tank needs to be opened, ensure it is drained according to your filter's manual.
- Access the Tube: Depending on your filter model, you may need to remove the filter lid or access port to reach the air relief tube connection point.
- Remove Old Tube: Carefully disconnect the old air relief tube from its fitting. Note its orientation and how it was routed within the filter.
- Install New Tube: Insert the new Pentair Air Relief Tube 150040 into the designated fitting. Ensure it is securely seated. The tube should extend into the filter tank to allow air to rise and escape effectively.
- Sikre forbindelser: If any clamps or fittings were loosened, tighten them appropriately to prevent leaks.
- Reassemble Filter: Close and secure the filter lid or access port according to the manufacturer's instructions.
- Genstart systemet: Ensure all valves are in the correct position. Turn on the pool pump. Open the manual air relief valve on the filter until a steady stream of water emerges, then close it. Check for any leaks.
5. Driftsprincip
The air relief tube operates passively within the filter system. As water enters the filter tank, any trapped air naturally rises. The air relief tube provides a clear path for this air to travel upwards and exit through the filter's air relief valve, preventing air from becoming trapped in the filter media or pump. This ensures continuous, efficient water flow and proper filtration.
6. Vedligeholdelse
Regular inspection of the air relief tube is recommended to ensure proper function.
- Visuel inspektion: Periodically inspect the tube for signs of wear, cracks, kinks, or blockages. A damaged or obstructed tube can prevent proper air relief.
- Rensning: If the tube appears dirty or clogged with debris, carefully remove it (following the installation steps in reverse, ensuring the system is depressurized) and clean it with water. Reinstall securely.
- Udskiftning: If the tube is brittle, cracked, or severely damaged, replace it with a genuine Pentair 150040 Air Relief Tube to maintain system integrity.
7. Fejlfinding
Issues related to the air relief tube often manifest as problems with air in the pool system.
Common Symptoms and Solutions:
- Air Bubbles from Return Jets: This indicates air is entering the system. While often due to leaks on the suction side, a faulty or blocked air relief tube can prevent air from escaping the filter, leading to it being pushed back into the pool. Inspect the air relief tube for blockages or damage.
- Filter Not Priming: If the pump struggles to prime or loses prime frequently, trapped air in the filter tank can be a cause. Ensure the air relief tube is clear and properly installed, allowing air to escape when the manual air relief valve is opened.
- High Filter Pressure: While less common for an air relief tube issue, severe air pockets can sometimes contribute to unusual pressure readings. Ensure the tube is not kinked or blocked.
If troubleshooting these steps does not resolve the issue, consult a qualified pool professional.
8. Specifikationer
| Attribut | Detalje |
|---|---|
| Modelnummer | 150040 |
| Produkttype | Luftaflastningsrør |
| Mærke | Pentair |
| Kompatibilitet | Pentair Triton II TR50 and TR60 Sand Filters (manufactured after 11/99) |
| Dimensioner (L x B x H) | 18 x 0.25 x 0.25 tommer |
| Varens vægt | 0.64 ounce |
| Materiale | Fleksibel slange |
9. Garantioplysninger
Pentair products are manufactured to high-quality standards. For specific warranty details regarding the Pentair Air Relief Tube 150040, please refer to the warranty documentation included with your original Pentair Triton II filter or visit the official Pentair webwebsted. Garantivilkår og -betingelser kan variere.
10. Support
If you require further assistance with the installation, operation, or troubleshooting of your Pentair Air Relief Tube or your Pentair Triton II filter system, please contact Pentair Customer Support or consult a certified pool technician.
- Pentair Officiel Webwebsted: www.pentair.com