Indledning
This manual provides essential instructions for the installation, operation, and maintenance of your Intermatic Pool Timer Switches. These switches, also known as trippers, are designed to work with Intermatic T101 and T104 series mechanical pool timers, enabling precise control over your pool equipment's ON and OFF cycles. Please read this manual thoroughly before use to ensure proper function and longevity of your timer system.
Produkt overview

Figur 1: Intermatic Pool Timer ON/OFF Trippers. Image shows one silver-colored 'ON' tripper and one gold-colored 'OFF' tripper, designed for Intermatic T101 and T104 series pool timers. These trippers are used to set the automatic operation schedule of the timer.
The Intermatic Pool Timer Switches consist of two distinct trippers: one silver-colored tripper for initiating the ON cycle and one gold-colored tripper for initiating the OFF cycle. These trippers attach to the rotating dial of compatible Intermatic mechanical timers, allowing you to program specific operating times for your pool pump or other equipment.
Opsætning og installation
- Sikkerhed først: Before handling the timer or installing the switches, ensure the power supply to the timer is completely disconnected at the circuit breaker.
- Identify Trippers: Locate the silver 'ON' tripper and the gold 'OFF' tripper. Each tripper has a small screw for attachment.
- Attach ON Tripper: Position the silver 'ON' tripper on the timer's rotating dial at the desired time you wish your pool equipment to activate. Secure it firmly using the small screw provided. Ensure the tripper is flush against the dial and does not obstruct its rotation.
- Attach OFF Tripper: Similarly, position the gold 'OFF' tripper on the timer's rotating dial at the desired time you wish your pool equipment to deactivate. Secure it with its screw.
- Bekræft placering: Gently rotate the timer dial manually to ensure both trippers are securely attached and do not interfere with each other or the timer mechanism.
- Gendan strøm: Once installation is complete and verified, restore power to the timer at the circuit breaker.
Note: Refer to your specific Intermatic T101 or T104 timer manual for detailed instructions on accessing the timer dial and any specific safety precautions.
Betjeningsvejledning
Once the ON and OFF trippers are installed, the Intermatic timer will automatically activate and deactivate your connected equipment according to the set schedule.
- Indstillingstid: Ensure the current time of day is correctly set on your Intermatic timer's dial. This is crucial for the trippers to function at the intended times.
- Adjusting Schedule: To change the ON/OFF times, simply loosen the screws on the respective trippers, slide them to the new desired positions on the dial, and re-tighten the screws. Always ensure power is disconnected before making adjustments.
- Manuel tilsidesættelse: Most Intermatic T101/T104 timers include a manual override switch. Consult your timer's main manual for instructions on how to temporarily override the programmed schedule without affecting the tripper settings.
Opretholdelse
- Regelmæssig inspektion: Periodically inspect the trippers for any signs of wear, corrosion, or looseness. Ensure the screws remain tight.
- Rensning: If dust or debris accumulates, gently wipe the trippers and the timer dial with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials.
- Opbevaring: If removing the trippers for an extended period, store them in a dry, safe place to prevent loss or damage.
Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Equipment does not turn ON/OFF at set times. | Trippers are loose or incorrectly positioned. Timer's current time is incorrect. Timer mechanism fault. | Ensure trippers are securely fastened and at the correct positions. Verify the timer's current time setting. If the timer itself is not functioning, consult the main timer manual or contact Intermatic support. |
| Trippers fall off the dial. | Skruerne er ikke spændt tilstrækkeligt. | With power disconnected, re-attach trippers and tighten screws firmly. Do not overtighten. |
| Difficulty attaching trippers. | Incorrect tripper type for timer model. Screw misalignment. | Confirm these trippers are compatible with your Intermatic T101 or T104 timer. Ensure the small screw aligns with the hole on the timer dial. |
Specifikationer
- Mærke: Intermatic
- Modelkompatibilitet: Intermatic T101, T104 Series Pool Timers
- Materiale: Plast
- Produktdimensioner: Approximately 0.2"D x 3"W x 0.2"H (for the set)
- Antal indstillinger: 2 (one ON, one OFF per cycle)
- Farve: Sort
Note on Color: While the product listing specifies "Black", the actual trippers are typically silver (ON) and gold (OFF) for easy identification, as shown in Figure 1. The "Black" specification may refer to packaging or a general product variant.
Garantioplysninger
Specific warranty details for Intermatic Pool Timer Switches are typically provided with the original product packaging or can be found on the official Intermatic website. Please retain your proof of purchase for warranty claims. For the most current and accurate warranty information, visit the Intermatic official webwebsted eller kontakt deres kundeservice direkte.
Kundesupport
For further assistance, technical support, or inquiries regarding your Intermatic Pool Timer Switches, please contact Intermatic customer service:
- Webwebsted: www.intermatic.com
- Kontaktoplysninger: Refer to the "Contact Us" section on the Intermatic webwebsted for telefonnumre og e-mailsupport.