Intermatic CT2000

Intermatic CT2000 Procenttage Cyklustidsafbryder Brugermanual

1. Introduktion

The Intermatic CT2000 Percentage Cycle Time Switch is designed for precise control of electrical loads based on a percentage of a selected cycle time. This device is suitable for various applications including ventilating fans, fogging equipment, process equipment, poultry and livestock feeders, and spraying equipment. It operates on 120/240 VAC at 60 Hz and features a NEMA 3R enclosure for durability. This manual provides essential information for the safe and effective installation, operation, and maintenance of your CT2000 timer.

2. Produktet er slutview

Nøglefunktioner:

  • Offers 8 field-selectable cycle durations: 30 seconds, 60 seconds (1 minute), 180 seconds (3 minutes), 5 minutes, 10 minutes, 30 minutes, 1 hour, and 4 hours.
  • Front cover push-button control for flexible repetitive cycle times.
  • Includes temporary and permanent manual override functions.
  • Three distinct positions allow for precise percentage ON time selection.
  • User settings are securely stored in non-volatile memory.

Komponenter:

The CT2000 features a clear dial for setting the percentage ON time, a 'Select Cycle Time' button, and indicator lights for cycle duration and ON/OFF status.

Intermatic CT2000 Procenttage Cycle Time Switch front view

Figur 1: Front view of the Intermatic CT2000 Percentage Cycle Time Switch. The image displays the main dial for percentage ON time selection, the 'Select Cycle Time' button, and a row of LEDs indicating the chosen cycle duration (30s, 60s, 180s, 5m, 10m, 30m, 1h, 4h). Instructions for programming the cycle timer are printed on the lower part of the device's label.

3. Opsætning og installation

Installation of the Intermatic CT2000 involves electrical wiring. It is recommended that installation be performed by a qualified electrician in accordance with all local and national electrical codes. Ensure power is disconnected at the circuit breaker before beginning any wiring.

Generelle monteringsbemærkninger:

  • The device is designed for surface mounting.
  • Connect the timer to a 120/240 VAC, 60 Hz power source.
  • Ensure proper grounding as per electrical safety standards.
  • Refer to the wiring diagram provided inside the unit's enclosure for specific connection details.

4. Betjeningsvejledning

The CT2000 allows you to set a specific cycle duration and then determine what percentage of that cycle the connected load will be ON.

Programming the Cycle Timer:

  1. Select Total Cycle Time: Turn the central knob until the "Select Cycle Time" arrow on the dial aligns with the triangle indicator. This action selects the total duration for one complete cycle (e.g., 30 seconds, 1 hour, 4 hours).
  2. Scroll Through Cycle Times: Push the 'Select Cycle Time' button to scroll through the available cycle durations. The corresponding LED above the dial will illuminate to indicate the currently selected cycle time.
  3. Save Desired Cycle Time: Once the desired cycle time is displayed by the LED, push and hold the 'Select Cycle Time' button until the LED blinks. This action saves the selected cycle duration.
  4. Set Percentage ON Time: Turn the central knob again until the desired percentage of the cycle time (e.g., 10%, 50%, 90%) aligns with the triangle indicator. This sets how long the load will be active within the chosen total cycle duration.

The timer will now operate according to your programmed settings. The 'OFF' and 'ON' indicators will show the current status of the output.

5. Vedligeholdelse

The Intermatic CT2000 Percentage Cycle Time Switch is designed for minimal maintenance. Regular inspection is recommended to ensure optimal performance.

Retningslinjer for vedligeholdelse:

  • Rensning: Tør jævnligt enhedens yderside af med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Inspektion: Annually inspect the wiring connections for tightness and signs of wear or corrosion. Ensure the enclosure remains sealed and free from damage.
  • Miljøforhold: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage. The NEMA 3R enclosure provides protection against rain, sleet, and external ice formation.

Afbryd altid strømmen, før du udfører vedligeholdelse eller inspektion.

6. Fejlfinding

If the Intermatic CT2000 is not functioning as expected, consider the following troubleshooting steps:

Almindelige problemer og løsninger:

  • Ingen strøm: Check the circuit breaker to ensure power is supplied to the unit. Verify all wiring connections are secure.
  • Load Not Activating: Confirm that the percentage ON time is set correctly and that the cycle duration is active. Check the connected load for functionality.
  • Forkert timing: Re-program the cycle time and percentage ON time following the operating instructions carefully. Ensure the LED blinks to confirm saving of the cycle duration.
  • Enheden svarer ikke: If the unit is completely unresponsive, disconnect power for a few minutes and then restore it. If the issue persists, professional assistance may be required.

For persistent issues or complex problems, contact Intermatic customer support or a qualified electrician.

7. Specifikationer

AttributSpecifikation
ModelnummerCT2000
MærkeIntermatic
MaterialeAluminium
Voltage Bedømmelse120/240 VAC, 60 Hz
Bedømmelse af kabinetNEMA 3R
Produktmål (D x B x H)3.31 cm x 3.5 cm x 6.63 cm
Varens vægt1.4 pund
Antal indstillinger8 (Cycle Durations)
Skift stilTryk knapkontakt
UPC078275124363

8. Garanti og support

Garantioplysninger:

The Intermatic CT2000 Percentage Cycle Time Switch comes with a 1 års begrænset garanti. This warranty covers replacement of the unit due to manufacturing defects but does not include labor costs for removal or reinstallation.

Kundesupport:

For teknisk assistance, garantikrav eller yderligere forespørgsler, kontakt venligst Intermatics kundesupport. Se den officielle Intermatic-manual. webwebstedet eller produktemballagen for de mest aktuelle kontaktoplysninger.

Relaterede dokumenter - CT2000

Preview Installations- og programmeringsvejledning til Intermatic EJ341C/EJ343C belysningstimer
Detaljerede instruktioner til installation og programmering af Intermatic EJ341C (enkeltpolet) og EJ343C (trevejs) belysningstimerkontakter. Dækker opsætning, styring, programmeringsmetoder, fejlfinding og specifikationer.
Preview Intermatic DT101 24-Hour Digital Time Switch: Installation and Operation Guide
A comprehensive guide for installing, programming, and operating the Intermatic DT101 24-Hour Digital Time Switch. Covers safety precautions, product specifications, setup, programming, operation modes, and warranty information.
Preview Intermatic TIME-ALL HB114 Kraftig 240V Timer - Opsætnings- og betjeningsvejledning
Omfattende guide til Intermatic TIME-ALL HB114 Heavy Duty 240V plug-in timeren, der dækker opsætning, programmering, manuel betjening, specifikationer og sikkerhedsadvarsler.
Preview Installations- og betjeningsvejledning til Intermatic Spring Wound Interval Timer
Detaljeret installations-, betjenings- og anvendelsesvejledning til Intermatic fjederviklede intervaltimere (FF- og FD-modeller). Indeholder kontaktklassificeringer, ledningsdiagrammer og garantioplysninger.
Preview Intermatic EJ351 Indendørs vægafbrydertimer: Installations-, programmerings- og fejlfindingsvejledning
Omfattende vejledning til installation, programmering og fejlfinding af Intermatic EJ351 indendørs vægkontakttimer. Lær, hvordan du indstiller tidsplaner, bruger automatiske og manuelle tilstande og løser almindelige problemer.
Preview Intermatic T1471BR 24-timers tidsafbryder: Installation og betjening
Detaljeret vejledning til Intermatic T1471BR 24-timers timer, der dækker installation, ledningsføring, programmering og betjeningsvejledning til pooludstyr og andre applikationer. Funktionerne omfatter Skipper®-funktionalitet og 4-polet enkeltkastdesign.