Fireangel CO-9X

Fireangel CO-9X 7 år bærbar kuliltealarm brugermanual

Model: CO-9X

1. Introduktion

This manual provides essential information for the proper installation, operation, and maintenance of your Fireangel CO-9X Carbon Monoxide Alarm. Please read these instructions carefully before use and retain them for future reference. This device is designed to detect carbon monoxide gas and alert occupants to its presence, helping to prevent carbon monoxide poisoning.

Fireangel CO-9X Carbon Monoxide Alarm

Image 1.1: The Fireangel CO-9X Carbon Monoxide Alarm, a compact white unit with a large test button and indicator lights.

2. Vigtige sikkerhedsoplysninger

Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. This alarm is designed to detect CO gas from any source of combustion. It is not a smoke alarm and does not detect fire. This device is not a substitute for proper maintenance of fuel-burning appliances, including ventilation and exhaust systems.

3. Produktet er slutview

The Fireangel CO-9X is a portable carbon monoxide alarm featuring a sealed-for-life battery designed to last 7 years. It includes visual indicators for power, fault, and CO detection, along with an audible alarm.

Close-up of Fireangel CO-9X indicator lights

Billede 3.1: Nærbillede view of the Fireangel CO-9X alarm's indicator lights and test button. The green LED indicates power, the amber LED indicates a fault, and the red LED indicates a CO alarm.

Komponenter:

4. Opsætning og installation

4.1. Aktivering

The Fireangel CO-9X alarm is activated by removing a small lanyard or activation tab from the battery compartment. Once activated, the green LED will flash, indicating the unit is operational. The sealed battery is designed to last for 7 years from activation.

4.2. Placeringsretningslinjer

For optimal protection, install carbon monoxide alarms in:

The alarm can be free-standing on a flat surface or wall-mounted using the provided fixings. When wall-mounting, ensure it is at least 150mm (6 inches) from the ceiling and at least 1 meter (3 feet) from any fuel-burning appliance to avoid false alarms from normal appliance operation.

Diagram showing recommended alarm placement in a house

Image 4.1: Diagram illustrating recommended placement for smoke, heat, and carbon monoxide alarms within a typical household. Carbon monoxide alarms are shown in areas near fuel-burning appliances and living spaces.

5. Betjeningsvejledning

5.1. Normal drift

During normal operation, the green Power LED will flash once every 45 seconds. This indicates the alarm is functioning correctly and monitoring for carbon monoxide.

5.2. Test af alarmen

Press and hold the large Test/Reset button for approximately 3 seconds. The alarm will emit a loud, pulsating sound, and the red CO Alarm LED will flash. Release the button to stop the test. Test the alarm monthly to ensure proper function.

5.3. Carbon Monoxide Alarm Condition

If carbon monoxide is detected, the alarm will sound a loud, pulsating signal (4 beeps, pause, 4 beeps) and the red CO Alarm LED will flash rapidly. If this occurs:

  1. Immediately move to fresh air outdoors or open all doors and windows.
  2. Foretag en hovedtælling for at kontrollere, at alle personer er medregnet.
  3. Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
  4. Call the emergency services or a qualified technician to investigate the source of the CO.

5.4. Fault/Low Battery Indication

If the amber Fault LED illuminates or the alarm chirps intermittently (e.g., once every 45 seconds) without the red CO Alarm LED flashing, it indicates a fault or a low battery. In this case, the unit needs to be replaced as the battery is sealed and not user-replaceable.

6. Vedligeholdelse

6.1. Rensning

Clean the alarm regularly to prevent dust buildup from affecting its performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning agents, solvents, or polishes, as these can damage the sensor or casing. Do not spray air fresheners, hairspray, or other aerosols near the alarm.

6.2. Batteri

The Fireangel CO-9X features a sealed-for-life battery with a 7-year lifespan. The battery is not user-replaceable. When the battery reaches the end of its life, the amber Fault LED will indicate a low battery, and the unit will need to be replaced.

7. Fejlfinding

ProblemTegnLøsning
Alarm sounds continuously (4 beeps, pause)Red CO Alarm LED flashing rapidly.Carbon Monoxide detected. Follow emergency procedures outlined in Section 5.3. Evacuate and ventilate the area. Contact emergency services.
Alarm chirps intermittently (e.g., every 45 seconds)Amber Fault LED illuminates.Low battery or fault. The unit has reached the end of its operational life or has a fault. Replace the alarm immediately.
Alarm does not respond to test buttonNo sound or light during test.Ensure the unit is activated (lanyard removed). If activated and still unresponsive, the unit is faulty. Replace the alarm.
Grøn strøm-LED blinker ikkeNo indication of power.Ensure the unit is activated. If activated, the unit may be faulty or at the end of its life. Replace the alarm.

8. Specifikationer

Certification marks for Fireangel CO-9X alarm

Image 8.1: Certification marks including the BSI Kitemark and CE mark, indicating compliance with European standards EN 50291-1:2010 +A1:2012 and EN 50291-2:2010.

9. Garanti og support

9.1. Garanti

The Fireangel CO-9X Carbon Monoxide Alarm comes with a 7-year manufacturer's warranty, covering defects in materials and workmanship from the date of purchase or activation. This warranty does not cover damage resulting from misuse, accident, or unauthorized modification.

9.2. Kundesupport

For further assistance, technical support, or warranty claims, please refer to the contact information provided on the product packaging or the manufacturer's official website. Ensure you have your product model number and date of purchase available when contacting support.

Relaterede dokumenter - CO-9X

Preview FireAngel CO-9X Kuliltedetektor med 7 års levetid brugermanual
Omfattende brugermanual til FireAngel CO-9X 7 års levetid kuliltealarm for giftig gas. Lær om installation, betjening, vedligeholdelse, sikkerhed og fejlfinding.
Preview FireAngel CO-9X Carbon Monoxide Alarm User Manual
User manual for the FireAngel CO-9X 7 Year Life Carbon Monoxide Poisonous Gas Alarm. Provides information on features, installation, operation, maintenance, and troubleshooting.
Preview FireAngel FA6813 Carbonmonoxidalarm brugermanual
Omfattende brugermanual til FireAngel FA6813 kuliltealarmen, der dækker installation, betjening, vedligeholdelse, fejlfinding og sikkerhedsoplysninger.
Preview FireAngel SCB10 Kombination af røg- og kuliltealarm brugermanual
Brugermanual til FireAngel SCB10, en kombineret røg- og kuliltealarm, der indeholder omfattende instruktioner om installation, betjening, vedligeholdelse og sikkerhed til brug i private hjem.
Preview FireAngel FA6812/FA6813 Kuliltealarm Brugermanual
Brugermanual til FireAngel FA6812 og FA6813 kuliltealarmer (CO), der indeholder instruktioner til installation, betjening, sikkerhed og vedligeholdelse.
Preview FireAngel Multisensor Plus brugermanual: Røg-, varme- og CO-detektor
Omfattende brugermanual til FireAngel Multisensor Plus og Multisensor Plus Kitchen, med detaljerede oplysninger om installation, betjening, sikkerhed, fejlfinding og tekniske specifikationer for røg-, varme- og kuliltedetektion.