Intermatic 2T2502GA

Intermatic 2T2502GA Pool/Spa Plastic Enclosure Timer Instruction Manual

Model: 2T2502GA

Indledning

This manual provides essential information for the proper installation, operation, and maintenance of the Intermatic 2T2502GA Pool/Spa Plastic Enclosure. This enclosure is designed to house compatible Intermatic T100 series time switches, offering protection in various environmental conditions.

Produkt overview

The Intermatic 2T2502GA is a durable, rainproof plastic enclosure specifically engineered for pool and spa timer applications. Its robust construction ensures longevity and protection for internal electrical components.

  • Materiale: Heavy-duty industrial grade plastic, beige finish.
  • Miljøvurdering: NEMA 3R rated for both indoor and outdoor installations, providing protection against rain, sleet, and external ice formation.
  • Rustforebyggelse: Constructed from plastic to prevent rust, making it ideal for humid or wet environments.
  • Kompatibilitet: Designed to house Intermatic T100 series time switches.
  • Knockouts: Features combination 0.5 and 0.75 inch nominal knockouts (one on the back, one on each side, and two on the bottom) for wiring convenience.
Intermatic 2T2502GA Plastic Enclosure, closed front view

Figur 1: Forside view of the Intermatic 2T2502GA Plastic Enclosure in its closed position. This image displays the beige finish and the Intermatic logo.

Sikkerhedsoplysninger

ADVARSEL: Risiko for elektrisk stød. Installation og service må kun udføres af kvalificeret personale.

  • Always disconnect power at the circuit breaker before installing or servicing the enclosure or any internal components.
  • Ensure all wiring complies with national and local electrical codes.
  • This plastic enclosure does not provide grounding for internal components. Proper grounding of the time switch and associated wiring must be established independently according to electrical codes.
  • Do not exceed the maximum electrical ratings of the time switch installed within the enclosure.

Installation og opsætning

  1. Monteringssted: Select a suitable indoor or outdoor location that is easily accessible for servicing and protected from physical damage. Ensure the surface is flat and capable of supporting the enclosure's weight.
  2. Montering af kabinettet:
    • Åbn skabets dør.
    • Use appropriate screws or fasteners (not included) to secure the enclosure to the mounting surface through the designated mounting holes.
  3. Preparing Knockouts:
    • Identify the required knockout locations (back, sides, bottom) for conduit entry.
    • Carefully remove the desired knockouts using a screwdriver and hammer. Exercise caution to avoid cracking the plastic.
    • Install appropriate conduit connectors and conduits.
  4. Installing the Time Switch:
    • The enclosure is designed for tool-free installation of compatible Intermatic T100 series time switches. The timer mechanism snaps into proprietary clips inside the box.
    • Refer to the specific instruction manual for your Intermatic T100 series time switch for detailed wiring instructions.
    • Sørg for, at alle elektriske forbindelser er sikre og korrekt isolerede.
  5. Jording: As this is a plastic enclosure, it does not provide an inherent ground path. Ensure that the time switch and all associated wiring are properly grounded according to local electrical codes. This may involve using a separate grounding conductor.
  6. Closing the Enclosure: Once installation and wiring are complete, securely close the enclosure door. The door features a tongue-in-groove design for a rainproof seal.
Intermatic 2T2502GA Plastic Enclosure, open view showing interior

Figur 2: Interiør view of the Intermatic 2T2502GA Plastic Enclosure with the door open. This image shows the internal mounting clips for the time switch and the knockout locations.

Opretholdelse

The Intermatic 2T2502GA enclosure requires minimal maintenance to ensure its protective function.

  • Rensning: Periodically clean the exterior of the enclosure with a damp klud til at fjerne snavs og rester. Undgå slibende rengøringsmidler.
  • Inspektion: Regularly inspect the enclosure for any signs of physical damage, such as cracks, loose hinges, or a compromised latch. Ensure the door closes securely to maintain its rainproof rating.
  • Seglintegritet: Verify that the tongue-in-groove seal around the door remains intact and free of debris to prevent water ingress.

Fejlfinding

This section addresses common issues related to the enclosure itself. For issues with the time switch, refer to its specific manual.

ProblemMulig årsagLøsning
Water inside enclosureDoor not fully closed; damaged seal; improperly installed conduit fittings.Ensure door is latched securely. Inspect door seal for damage and replace if necessary. Verify conduit fittings are tight and sealed.
Enclosure door does not close securelyDamaged latch or hinges; obstruction.Inspect latch and hinges for damage. Clear any obstructions. If damaged, the enclosure may need replacement.
Revnet plastikPhysical impact; improper knockout removal.A cracked enclosure compromises its NEMA 3R rating. Replace the enclosure immediately to maintain protection.

Specifikationer

  • Model: 2T2502GA
  • Mærke: Intermatic
  • Materiale: Heavy-duty Industrial Grade Plastic
  • Slutte: Beige
  • Miljøvurdering: NEMA 3R (Rainproof)
  • Dimensioner (H x B x D): 9-3/8 inches (23.8 cm) x 5-1/2 inches (14.0 cm) x 3-5/8 inches (9.2 cm)
  • Knockouts: Combination 0.5 and 0.75 inch nominal (one back, two sides, two bottom)
  • Kompatibilitet: Intermatic T100 series time switches

Garanti og support

Garanti: This product is covered by a 1-year warranty for replacement of the unit. Labor costs are not included.

For technical support or warranty claims, please contact Intermatic customer service. Refer to the official Intermatic webhjemmeside for aktuelle kontaktoplysninger.

Note: Warranty terms are subject to change. Please refer to the official Intermatic warranty statement for the most up-to-date information.

Relaterede dokumenter - 2T2502GA

Preview Intermatic All-Plastic Rainproof Time Switch Enclosure Installation Instructions
Detailed installation guide for the Intermatic all-plastic rainproof time switch enclosure, covering case mounting, conduit connections, and grounding requirements according to the National Electric Code.
Preview Sådan betjenes og indstilles Intermatic T100-seriens timere
En omfattende guide til betjening og indstilling af mekaniske timere i Intermatic T100-serien, inklusive modellerne T101, T103, T104, T105 og T106. Lær om timerspecifikationer, sikkerhedsforanstaltninger, indstilling af ON/OFF-udløsere, brug af manuel overstyring og find ressourcer til fejlfinding og reservedele.
Preview Installations- og programmeringsvejledning til Intermatic EJ341C/EJ343C belysningstimer
Detaljerede instruktioner til installation og programmering af Intermatic EJ341C (enkeltpolet) og EJ343C (trevejs) belysningstimerkontakter. Dækker opsætning, styring, programmeringsmetoder, fejlfinding og specifikationer.
Preview Intermatic ET8215C Elektronisk Timerstyring - Tekniske Data
Detaljerede tekniske specifikationer for Intermatic ET8215C elektronisk timerstyring, en astronomisk 7-dages, 2-kreds elektronisk styring egnet til 120-277 VAC applikationer i et indendørs metalkabinet.
Preview Intermatic T173 T170 Mekanisk timerafbryder - 24 timer, 125V, 5HK
Detaljerede specifikationer for Intermatic T173 T170 mekanisk timerafbryder. Har 24-timers indstilling, 125 VAC, 5 HK motoreffekt, 2NO DPST-kontakter og NEMA 1-kapsling. Velegnet til kommercielle, industrielle, private, udendørs og HVACR-applikationer.
Preview Intermatic EI210 Elektronisk Nedtællingstimer til Indbygning i Væg - Installations- og Brugervejledning
Omfattende guide til den elektroniske vægindbyggede nedtællingstimer Intermatic EI210, med detaljerede funktioner, installationstrin, driftstilstande (Timer og Hold) og garantioplysninger. Indeholder tekniske specifikationer og kontaktoplysninger for Intermatic Incorporated.