1. Introduktion og overview
The Taco SR504-2 is a 4-zone switching relay designed for hydronic heating systems. It provides control for up to four independent heating zones, allowing each zone to be managed by its own thermostat. This unit incorporates a priority feature, which ensures that a designated zone (typically the domestic hot water zone) receives heating priority over other zones when activated. The SR504-2 is engineered for reliable and efficient operation in residential and light commercial applications, simplifying wiring and control for multi-zone heating systems.
2. Opsætning og installation
Installation of the Taco SR504-2 should be performed by a qualified heating technician or electrician in accordance with all local codes and regulations. Ensure power to the heating system is disconnected at the main service panel before beginning any installation work.
2.1 Montering:
- The SR504-2 is designed for DIN Rail mounting. Securely attach the unit to a suitable surface in a dry, accessible location near the boiler and zone valves/circulators.
- Sørg for tilstrækkelig ventilation omkring enheden for at forhindre overophedning.
2.2 Ledningsføring:
- All wiring connections are made via screw terminals. Refer to the wiring diagram provided with the physical product for specific connections.
- Tilslut hovedstrømforsyningen til de dertil indrettede terminaler.
- Connect each zone thermostat to its respective zone input terminals.
- Connect the zone valves or circulators to their corresponding zone output terminals.
- Connect the boiler control terminals to the boiler's thermostat input.
- Identify and connect the priority zone thermostat and circulator/valve to the priority terminals.

Image 1: The Taco SR504-2 4-Zone Switching Relay. This image displays the compact, green-cased unit with visible labeling for the Taco brand and model number SR504. The unit features connection points on the top surface, indicating its role as a central control component for heating systems.
3. Betjeningsvejledning
The Taco SR504-2 operates automatically based on thermostat calls from each connected zone.
- Zone Activation: When a thermostat in any of the four zones calls for heat, the SR504-2 activates the corresponding zone valve or circulator and signals the boiler to fire.
- Priority Function: If the designated priority zone (e.g., domestic hot water) calls for heat, the SR504-2 will temporarily suspend heating to non-priority zones to ensure the priority zone is satisfied first. Once the priority zone's demand is met, the relay will resume normal operation for other zones.
- Indikatorlys: The unit typically features indicator lights for each zone and for boiler activation, providing visual confirmation of system status. Refer to the product's specific labeling for light functions.
4. Vedligeholdelse
The Taco SR504-2 is designed for long-term, maintenance-free operation. Regular maintenance is generally not required for the relay itself, but periodic inspection of the overall heating system is recommended.
- Årlig inspektion: During routine heating system maintenance, have a qualified technician inspect the wiring connections to the SR504-2 to ensure they are secure and free from corrosion.
- Miljøforhold: Ensure the unit remains in a dry environment, free from excessive dust or moisture.
- Rensning: If necessary, gently wipe the exterior of the unit with a dry, soft cloth. Do not use liquid cleaners or solvents.
There are no user-serviceable parts inside the SR504-2. Do not attempt to open or repair the unit.
5. Fejlfinding
If you experience issues with your heating system, consider the following troubleshooting steps. Always disconnect power before inspecting wiring.
- No Heat in a Zone:
- Check the thermostat for that zone to ensure it is calling for heat and set above the ambient temperature.
- Verify that the zone valve or circulator for that zone is functioning correctly.
- Inspect wiring connections at the SR504-2 and the zone components.
- No Heat in Any Zone:
- Ensure the main power supply to the SR504-2 is active. Check circuit breakers.
- Verify the boiler is operational and receiving the call for heat from the SR504-2.
- Check the main thermostat (if applicable) or boiler controls.
- Priority Zone Not Functioning Correctly:
- Ensure the priority zone thermostat is calling for heat.
- Verify the priority zone's wiring is correctly connected to the designated priority terminals on the SR504-2.
Hvis disse trin ikke løser problemet, anbefales det at kontakte en kvalificeret HVAC-tekniker for yderligere diagnose og reparation.
6. Specifikationer
| Modelnummer | SR504-2 |
| Mærke | Taco |
| Antal zoner | 4 |
| Priority Feature | Ja |
| Driftstilstand | Automatisk |
| Kontakt Nuværende vurdering | 5 Amps |
| Connector Type | Skrue |
| Kontaktmateriale | Silver, Gold, Copper |
| Monteringstype | DIN-skinneophæng |
| Produktdimensioner | 14 x 9 x 3 tommer |
| Varens vægt | 6 pund |
| UPC | 687752389531 |
7. Garanti og support
For specific warranty information regarding your Taco SR504-2, please refer to the documentation included with your product at the time of purchase or visit the official Taco Comfort Solutions website. Warranty terms typically cover manufacturing defects for a specified period from the date of installation.
For technical support, service, or to locate an authorized service provider, please contact Taco Comfort Solutions customer service directly. Contact information can usually be found on the product packaging or their official webwebsted.