1. Introduktion
The Intermatic PF1202T Control System is designed to manage pool and spa equipment operation, incorporating essential freeze protection. This system features two T104M mechanisms for precise scheduling and an adjustable thermostat to safeguard your equipment against freezing temperatures. It is suitable for installations requiring one or two time switches.
Key features of this control system include:
- User-adjustable thermostat for freeze protection.
- Designed for pools requiring one or two time switches.
- Protects pool and spa equipment against freeze damage.
- Automatically activates the pump and heater when outdoor temperature drops below the set point.
2. Sikkerhedsoplysninger
ADVARSEL: To avoid serious injury or death, always disconnect power at the circuit breaker or fuse box before installing or servicing this control system. Installation and servicing should be performed by a qualified electrician in accordance with all national and local electrical codes.
- Læs alle instruktioner, før du installerer eller betjener enheden.
- Sørg for, at strømforsyningen matcher voltage rating of the control system (240 Volts).
- Do not operate the unit with damaged wiring or if the enclosure is compromised.
- Keep the enclosure door closed and secured during operation to prevent accidental contact with live parts.
- This device is intended for outdoor use and must be installed in a location protected from direct water spray.
3. Opsætning og installation
3.1. Udpakning
Carefully remove the control system from its packaging. Inspect the unit for any signs of damage during transit. Retain all packaging materials until you have confirmed the unit is in working order.
3.2. Montering
Mount the control system vertically on a flat, rigid surface using appropriate fasteners. Ensure the mounting location allows for proper ventilation and access for wiring and maintenance. The enclosure is designed for outdoor use.
3.3. Ledninger
VIGTIG: All wiring must be performed by a qualified electrician and comply with local and national electrical codes. The unit operates at 240 Volts and has a current rating of 17 Amps. Use appropriate gauge wiring for the load. The terminal type is screw-type for secure connections.
Refer to the wiring diagram located inside the control system's door for specific connection details. Ensure all connections are tight and secure before restoring power.

Figur 1: Intermatic PF1202T Control System with the front door open. The image displays the internal components, including two yellow time switch mechanisms at the top, each with ON/OFF levers. Below these are two blank cover plates, and on the left side, a black dial for the freeze protection thermostat, labeled with temperature settings from 32°F to 44°F. The inside of the door shows a wiring diagram and product information label.
4. Betjeningsvejledning
4.1. Setting the T104M Time Switches
The PF1202T includes two T104M time switches to control your pool or spa equipment. Each time switch allows for independent scheduling of ON/OFF cycles.
- Indstil aktuel tid: Pull out the dial and rotate it clockwise until the current time aligns with the arrow on the mechanism. Push the dial back in.
- Indstil TIL/FRA-tider: Each time switch comes with ON (green) and OFF (red) trippers. To set an ON time, slide a green tripper onto the dial at the desired ON time. To set an OFF time, slide a red tripper onto the dial at the desired OFF time. Additional trippers can be purchased separately for more complex schedules.
- Manuel tilsidesættelse: The red lever below each dial allows for manual override. Moving the lever to "ON" or "OFF" will temporarily override the programmed schedule until the next tripper engages. Ensure the lever is in the "AUTO" position for automatic operation.
4.2. Adjusting the Freeze Protection Thermostat
The integrated freeze protection thermostat automatically activates your pump and/or heater when the ambient temperature drops to a critical level, preventing freeze damage to your plumbing and equipment.
- Locate the black dial labeled "FREEZE PROTECTION THERMOSTAT" on the lower left side of the control panel (refer to Figure 1).
- Rotate the dial to set the desired outdoor temperature at which the pump operation should begin. Common settings range from 32°F to 44°F.
- It is recommended to set the thermostat slightly above the typical freezing point for your region to provide an adequate buffer.
5. Vedligeholdelse
The Intermatic PF1202T Control System requires minimal maintenance. Regular inspection can help ensure long-term reliable operation.
- Årlig inspektion: Annually, or more frequently in harsh environments, inspect the enclosure for any signs of corrosion, damage, or loose connections.
- Rensning: Keep the exterior of the enclosure clean and free of debris. Use a soft, damp klud til rengøring. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Ledningskontrol: Periodically check all wiring connections for tightness. Loose connections can lead to overheating and potential hazards.
- Thermostat Sensor: Ensure the freeze protection thermostat sensor is clear of obstructions and debris to allow for accurate temperature readings.
6. Fejlfinding
This section provides solutions to common issues you may encounter with your PF1202T Control System. For problems not listed here, or if solutions do not resolve the issue, contact a qualified electrician or Intermatic customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Equipment does not turn ON/OFF at scheduled times. |
|
|
| Freeze protection not activating. |
|
|
| Enheden har ingen strøm. |
|
|
7. Specifikationer
Technical specifications for the Intermatic PF1202T Control System:
| Feature | Detalje |
|---|---|
| Mærke | Intermatic |
| Model | PF1202T |
| Driftstilstand | ON-OFF-ON |
| Nuværende vurdering | 17 Amps |
| Operation Voltage | 240 volt |
| Kontakttype | Normalt åben |
| Connector Type | Skrue |
| Terminal | Skrue type |
| Varemål L x B x H | 6 x 12 x 14 tommer |
| Kredsløbstype | 1-vejs |
| Aktuator type | Tryk knap |
8. Garanti og support
Intermatic products are manufactured to high-quality standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Intermatic webwebsted.
For technical assistance, troubleshooting, or to inquire about replacement parts, please contact Intermatic customer support. Contact information can typically be found on the manufacturer's webwebstedet eller på produktemballagen.