Cooper-Atkins 26HP-01-1

Cooper-Atkins 26HP-01-1 Varmtholdende Termometer Brugsanvisning

Model: 26HP-01-1

1. Produktet er slutview

The Cooper-Atkins 26HP-01-1 is a robust hot holding cabinet thermometer designed for accurate temperature monitoring in commercial food service environments. This mechanical dial thermometer ensures food safety by verifying that hot foods are maintained at safe temperatures.

Cooper-Atkins 26HP-01-1 Hot Holding Thermometer in packaging

Image 1.1: The Cooper-Atkins 26HP-01-1 Hot Holding Thermometer, shown in its original packaging.

Nøglefunktioner:

  • Hot Holding Cabinet Thermometer: Specifically designed for monitoring temperatures in hot holding units.
  • NSF certificeret: Opfylder standarder for folkesundhed og sikkerhed.
  • Stainless Steel Case: Durable construction for commercial use.
  • Glas linse: Provides clear visibility of the temperature dial.
  • Printed Dial Display: Letlæseligt analogt display.

2. Opsætning og placering

The 26HP-01-1 thermometer is designed for straightforward use. No assembly or battery installation is required as it is a mechanical device.

Indledende inspektion:

  • Remove the thermometer from its packaging.
  • Inspect the thermometer for any visible damage to the case, lens, or dial. Do not use if damaged.

Placement in Hot Holding Cabinet:

  1. Place the thermometer in a central location within the hot holding cabinet.
  2. Ensure the thermometer is not directly touching heating elements or cold spots, which could lead to inaccurate readings.
  3. Position the thermometer so that the dial is easily visible for regular monitoring. The integrated stand allows for stable placement on a flat surface.

3. Betjeningsvejledning

This thermometer provides continuous temperature monitoring for hot holding applications. It is calibrated to indicate temperatures relevant for food safety.

Reading the Thermometer:

  • The thermometer features a clear dial with temperature markings in both Fahrenheit and Celsius.
  • The red zone on the dial indicates the safe hot holding temperature range, typically 140°F (60°C) and above, as recommended for many food safety guidelines.
  • Regularly check the thermometer to ensure that food in the hot holding cabinet is maintained at or above the minimum safe temperature.

Important Food Safety Guidelines:

  • Always hold hot foods at 140°F (60°C) or above to prevent bacterial growth.
  • Never use this thermometer to cook foods. It is designed for monitoring holding temperatures only.
  • If the temperature falls below the safe holding zone, take immediate corrective action, such as reheating the food to a safe temperature or discarding it, according to local food safety regulations.

4. Vedligeholdelse og pleje

Proper care ensures the longevity and accuracy of your Cooper-Atkins thermometer.

Rensning:

  • Wipe the thermometer clean with a damp klud og mildt rengøringsmiddel.
  • Nedsænk ikke hele termometret i vand.
  • Tør grundigt efter rengøring.
  • Avoid using abrasive cleaners or scouring pads, as these can damage the stainless steel finish and glass lens.

Opbevaring:

  • Opbevar termometret et rent og tørt sted, når det ikke er i brug.
  • Protect the thermometer from extreme temperatures and physical shocks.

5. Fejlfinding

The Cooper-Atkins 26HP-01-1 is a simple, mechanical device. Most issues relate to placement or physical damage.

ProblemMulig årsagLøsning
Unøjagtig temperaturaflæsning
  • Improper placement (too close to heating element/cold spot).
  • Physical damage to the thermometer.
  • Relocate the thermometer to a central area within the hot holding cabinet.
  • If physically damaged, replace the thermometer.
Dial is difficult to read
  • Condensation on the lens.
  • Snavs eller affald på linsen.
  • Ensure the cabinet environment is not excessively humid.
  • Clean the glass lens as per maintenance instructions.

6. Specifikationer

AttributDetalje
Modelnummer26HP-01-1
MærkeCooper-Atkins
Produktdimensioner7 x 4.2 x 0.2 tommer
Varens vægt0.48 ounce
YdermaterialeRustfrit stål
Display TypeAnalog (Printed Dial)
Speciel funktionHøj nøjagtighed
CertificeringNSF certificeret
Inkluderede komponenterHot Holding Thermometer
ProduktplejevejledningTør Clean

7. Garantioplysninger

Specific warranty details for the Cooper-Atkins 26HP-01-1 Hot Holding Thermometer are typically provided at the point of purchase or on the manufacturer's official website. Please refer to the documentation included with your product or visit the Cooper-Atkins webwebstedet for den seneste garantipolitik.

8. Kundesupport

For further assistance, technical support, or inquiries regarding your Cooper-Atkins 26HP-01-1 Hot Holding Thermometer, please contact Cooper-Atkins customer service. Contact information can usually be found on the official Cooper-Atkins webwebstedet eller på produktemballagen.

You can visit the official Cooper-Atkins store on Amazon for more products and information: Cooper-Atkins Store

Relaterede dokumenter - 26HP-01-1

Preview Cooper-Atkins DFP450W digitalt lommetermometer
Cooper-Atkins DFP450W er et digitalt lommetermometer designet til at måle opvaskemaskiners slutskylningstemperaturer. Det har et bredt temperaturområde, høj nøjagtighed, hukommelse til maksimal temperatur og automatisk slukning. Apparatet er NSF-certificeret og ideelt til fødevareindustrien og tilbyder et sikkert alternativ til kviksølvtermometre.
Preview Instruktioner til firmwareopdatering af Cooper-Atkins multifunktionstermometer
Trinvise instruktioner til opdatering af firmwaren på Cooper-Atkins multifunktionstermometer (MFT) ved hjælp af Blue2 Reader-appen. Indeholder oplysninger om download af appen, tilslutning af MFT'en og verifikation af opdateringen.
Preview Cooper-Atkins 20200 multifunktionstermometer instruktioner
Instruktioner til Cooper-Atkins 20200 multifunktionstermometeret, med detaljerede oplysninger om dets funktioner, betjening og specifikationer, herunder Bluetooth-forbindelse og temperaturmålingsmuligheder.
Preview HACCP Manager hurtigstartguide
Lynstartvejledning til Cooper-Atkins HACCP Manager håndholdte instrument, med detaljerede oplysninger om softwareinstallation, programstart, datasynkronisering, upload, strømstyring og opladningsinstruktioner.
Preview Cooper-Atkins SysCal 93025 kalibreringssystem: Brugervejledning og garanti
Omfattende brugervejledning og garantioplysninger til Cooper-Atkins SysCal 93025 kalibreringssystemet, med detaljerede betjeningsvejledninger, kalibreringsprocedurer, fejlfinding og systemspecifikationer.
Preview Cooper-Atkins produktkatalog: Temperatur- og fugtighedsmåling, timere og overvågningsløsninger
Udforsk det omfattende Cooper-Atkins produktkatalog, der indeholder avancerede temperatur- og fugtighedstermometre, pålidelige timere og innovative overvågningsløsninger. Opdag produkter til fødevareindustrien, sundhedsvæsenet og industrien, herunder TempTrak, NotifEye og HACCP Manager-systemer.