Amprobe SM-CAL1

Amprobe SM-CAL1 Lydmålerkalibrator Brugermanual

Model: SM-CAL1

1. Introduktion

De Amprobe SM-CAL1 is a precision sound meter calibrator designed to ensure the accuracy and reliability of your sound level measurements. This device generates two fixed sound pressure levels, 94 decibels (dB) and 114 dB, at a frequency of 1,000 hertz (Hz), allowing for precise calibration of sound meters with microphones up to 1/2 inch in diameter. Regular calibration is crucial for maintaining measurement integrity and compliance with relevant standards.

This manual provides detailed instructions for the proper use, maintenance, and troubleshooting of your SM-CAL1 Sound Meter Calibrator.

2. Sikkerhedsoplysninger

Please read and understand all safety instructions before operating the SM-CAL1. Failure to follow these guidelines may result in injury or damage to the device.

  • Do not expose the calibrator to extreme temperatures, humidity, or direct sunlight.
  • Undgå at tabe eller udsætte enheden for kraftige stød.
  • Do not attempt to open or modify the calibrator. Refer all servicing to qualified personnel.
  • Sørg for, at batterirummet er forsvarligt lukket under drift.
  • Bortskaf batterier i henhold til lokale regler.

3. Pakkens indhold

Bekræft at alle varer er til stede i pakken:

  • Amprobe SM-CAL1 Sound Meter Calibrator
  • One (1) 9V battery (installed)
  • Brugervejledning (denne manual)

4. Opsætning

4.1 Batteriinstallation

The SM-CAL1 comes with a 9V battery pre-installed. If replacement is needed:

  1. Find batteridækslet i bunden af ​​enheden.
  2. Fjern dækslet.
  3. Tilslut et nyt 9V batteri, og overhold den korrekte polaritet.
  4. Sæt batterirummets dæksel på igen.

4.2 Preparing for Calibration

Before calibrating your sound meter, ensure its microphone is clean and free of debris. The SM-CAL1 is designed to fit microphones with a diameter of up to 1/2 inch.

Amprobe SM-CAL1 Sound Meter Calibrator with power switch and display showing 94 114 OFF db at 1kHz, IEC 942 1988 CLASS 2, and Sound Calibrator.

Figur 1: Amprobe SM-CAL1 Sound Meter Calibrator. The image shows the top face of the cylindrical calibrator, featuring the 'AMPROBE' logo, 'SM-CAL1' model number, a three-position slide switch labeled '94', 'OFF', and '114' (referring to dB levels), and text indicating 'db at 1kHz', 'IEC 942 1988 CLASS 2', and 'Sound Calibrator'. A red power indicator light is also visible.

5. Betjening

5.1 Calibrating a Sound Meter

  1. Gently insert the microphone of your sound level meter into the opening on the top of the SM-CAL1 calibrator. Ensure a snug fit to minimize sound leakage.
  2. Select the desired calibration level using the slide switch on the calibrator:
    • Slide to '94' for a 94 dB signal.
    • Slide to '114' for a 114 dB signal.
  3. Observe the reading on your sound level meter. Adjust your sound meter's calibration settings until its display matches the selected output level of the SM-CAL1 (either 94 dB or 114 dB). Refer to your sound meter's user manual for specific calibration adjustment procedures.
  4. Once calibration is complete, slide the switch to 'OFF' to conserve battery life.
  5. Carefully remove the sound meter's microphone from the calibrator.

5.2 Indikation for lavt batteriniveau

The SM-CAL1 is equipped with a low-battery indicator. When the battery voltage drops below a certain level, the indicator light will dim or not illuminate, signaling that the 9V battery needs to be replaced.

6. Vedligeholdelse

6.1 Rengøring

To clean the exterior of the calibrator, use a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the casing eller interne komponenter.

6.2 Opbevaring

When not in use, store the SM-CAL1 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to remove the 9V battery to prevent leakage.

6.3 Recalibration of the SM-CAL1

While the SM-CAL1 is designed for stable output, periodic verification of its accuracy by a certified calibration laboratory is recommended to ensure continued compliance with standards and optimal performance. The frequency of such recalibration depends on usage and regulatory requirements.

7. Fejlfinding

ProblemMulig årsagLøsning
No sound output / Power indicator offBatteriet er dødt eller forkert installeret.Udskift 9V-batteriet, og sørg for korrekt polaritet.
Inaccurate calibration readings on sound meterMicrophone not properly seated; Calibrator needs recalibration; Sound meter issue.Ensure microphone is snugly fitted. Consider sending SM-CAL1 for professional recalibration. Check your sound meter's functionality.
Sound meter reading fluctuatesAmbient noise interference; Loose microphone connection.Perform calibration in a quiet environment. Re-seat the microphone firmly.

8. Specifikationer

  • Model: SM-CAL1
  • Output Sound Pressure Levels: 94 dB og 114 dB
  • Udgangsfrekvens: 1,000 Hz (1 kHz)
  • Mikrofonkompatibilitet: Fits microphones up to 1/2 inch diameter
  • Nøjagtighed: Meets IEC 942 1988 Class 2 standards
  • Strømkilde: One (1) 9V battery
  • Indikator for lavt batteri: Ja
  • Driftstemperatur: 0°C til 40°C (32°F til 104°F)
  • Opbevaringstemperatur: -10°C til 50°C (14°F til 122°F)
  • Dimensions (H x D): Approximately 4.9 x 1.9 inches (125 x 48 mm)
  • Vægt: Cirka 0.6 g (285 lb)
  • Certificeringer: CE compliant, ANSI, IEC standards

9. Garanti og support

9.1 Garantioplysninger

Amprobe products are warranted against defects in material and workmanship for a specified period from the date of purchase. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Ampkappe website. This warranty does not cover damage resulting from misuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling.

9.2 Kundesupport

Hvis du støder på problemer eller har spørgsmål vedrørende din Amprobe SM-CAL1 Sound Meter Calibrator, please contact Amprobe customer support. Before contacting support, ensure you have reviewed the troubleshooting section of this manual. You can find contact information on the official Ampkappe webwebstedet eller gennem din lokale distributør.

Relaterede dokumenter - SM-CAL1

Preview Amprobe AM-420 Digitalt Multimeter Brugermanual
Brugermanual til Amprobe AM-420 digitalt multimeter, der beskriver dets funktioner, målemuligheder, sikkerhedsforanstaltninger og specifikationer for elektrisk testning. Velegnet til både privat og professionel brug.
Preview AmpBrugermanual til robe CR50A kapacitans- og modstandsmåler
Denne brugermanual indeholder omfattende instruktioner til betjening af Amprobe CR50A kapacitans- og modstandsmåler, der dækker dens funktioner, måleprocedurer, sikkerhedsretningslinjer og tekniske specifikationer.
Preview AmpBrugermanual til robe AT-3500 Underjordisk Kabel-/Rørfindersystem
Omfattende brugermanual til Amprobe AT-3500 underjordisk kabel-/rørlokaliseringssystem, der beskriver drift, funktioner, tekniske specifikationer og vedligeholdelse for præcis detektion af underjordiske forsyningsledninger.
Preview Amprobe TT-200 Butt Set Instruktionsmanual - Linjetestning og kommunikation
Omfattende instruktionsmanual til Amprobe TT-200 Butt Set, der beskriver dets funktioner til linjetestning, måling af isolationsmodstand og midlertidig kommunikation for teknikere.
Preview AmpBrugermanual til robe IR-750 / IR-750-EUR 50:1 infrarødt termometer
Brugermanual til Amprobe IR-750 og IR-750-EUR 50:1 infrarøde termometre. Funktionerne omfatter bredt temperaturområde, høj nøjagtighed, laserpointer, datalogning og USB-tilslutning til industrielle og professionelle anvendelser.
Preview Amprobe UAT-600 Underjordisk Forsyningsfinder Hurtigstartguide
En hurtigstartguide til Amprobe UAT-600-serien af ​​underjordiske forsyningssøgere, der giver instruktioner om aktiv og passiv lokalisering af forsyningsledninger ved hjælp af forskellige tilstande som strøm, radio, induktion, direkte testledninger og signalafbrydelse.amp.