This smoke alarm detects products of combustion using ionization technology. Ionization smoke alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. For maximum protection, it is recommended to install both ionization and photoelectric smoke alarms.

  • Mal ikke alarmen. Paint can clog the sensing chambers and prevent the alarm from operating properly.
  • Do not disconnect power. This alarm is designed for continuous operation.
  • Test alarmen ugentligt. Refer to the 'Operation' section for testing instructions.
  • Udskift alarmen hvert 10. år. Smoke alarms have a limited lifespan and should be replaced after 10 years from the date of manufacture.

Installationsvejledning

The Kidde i12060 is a hardwired smoke alarm designed for permanent installation. Ensure power is off at the circuit breaker before beginning installation.

  1. Forbered ledningsføring: The alarm comes with a pre-stripped wiring harness with tinned strands for easy connection. Connect the black wire to the hot line, the white wire to neutral, and the orange wire to the interconnect line (if connecting multiple alarms).
  2. Monter basen: Secure the mounting bracket to the ceiling or wall using the provided screws. The large mounting base helps cover imperfections and protect surface paint.
  3. Connect Alarm: Plug the wiring harness into the back of the smoke alarm.
  4. Attach Alarm to Base: Juster alarmen med monteringsbeslaget, og drej den med uret, indtil den klikker på plads.
  5. Activate Battery Backup: Remove the battery pull tab to activate the included 9-volt battery backup. This ensures continuous protection during power outages.
  6. Gendan strøm og test: Turn on the power at the circuit breaker and test the alarm as described in the 'Operation' section.
Back of Kidde i12060 smoke alarm showing mounting plate and wiring harness

Billede: Bagside view of the Kidde i12060 smoke alarm, illustrating the mounting plate and the pre-stripped wiring harness for electrical connection.

Person installing a smoke alarm on a ceiling

Image: A person reaching up to install the smoke alarm onto the ceiling mounting bracket, demonstrating the final step of physical installation.

Operation

Once installed and powered, your Kidde i12060 smoke alarm is ready to protect your home. It features an indicator LED and a test/hush button for easy interaction.

Test af alarmen

It is crucial to test your smoke alarm weekly to ensure proper function.

  • Press and hold the 'TEST' button located on the front of the alarm.
  • The alarm will sound a loud, pulsating alarm. This indicates the electronic circuitry, horn, and battery are working.
  • Slip knappen. Alarmen stopper.

Using the Hush Feature

The 'HUSH' feature temporarily silences nuisance alarms caused by non-emergency situations, such as cooking fumes.

  • Press the 'HUSH' button when a nuisance alarm sounds.
  • The alarm will be desensitized for approximately seven minutes. During this time, the alarm will chirp every 30 to 40 seconds.
  • If smoke is too dense, the hush feature will be overridden, and the alarm will continue to sound.
  • The alarm automatically resets at the end of the seven-minute period.
Front of Kidde i12060 smoke alarm with test and hush buttons

Image: Close-up of the front of the Kidde i12060 smoke alarm, highlighting the 'TEST' and 'HUSH' buttons for operational control.

Vedligeholdelse og udskiftning af batteri

Regular maintenance ensures your smoke alarm remains functional and reliable.

Udskiftning af batteri

The i12060 features a convenient front-loading battery door, allowing you to replace the 9-volt battery without removing the alarm from its mounting bracket.

  1. Open the front battery door by sliding the latch or pressing the designated area.
  2. Remove the old 9-volt battery.
  3. Insert a new 9-volt alkaline battery, ensuring correct polarity.
  4. Luk batteridækslet forsvarligt.
  5. Test alarmen efter udskiftning af batteriet.

The alarm will chirp approximately once every 30-40 seconds when the battery is low. Replace the battery immediately when this occurs.

Rengøring af din alarm

Clean your smoke alarm at least once a year. Use a soft brush or cloth to remove dust from the alarm's cover. Do not use cleaning solvents or spray directly onto the alarm.

Kidde i12060 smoke alarm with front battery compartment open

Image: The Kidde i12060 smoke alarm with its front battery compartment open, clearly showing the 9-volt battery slot for easy replacement.

Fejlfinding

Problem Mulig årsag Løsning
Alarmen bipper hvert 30-40 sekund. Lavt batteri. Replace the 9-volt battery immediately.
Alarm sounds frequently without apparent smoke. Nuisance alarm (e.g., cooking fumes, steam), dust accumulation. Use the 'HUSH' feature. Clean the alarm as described in the 'Maintenance' section. Ensure proper placement away from cooking areas or high humidity.
Alarmen lyder ikke under testen. Ingen strøm, dødt batteri, defekt enhed. Check circuit breaker. Replace battery. If issues persist, replace the alarm.
Alarm is over 10 years old. Slut på levetid. Udskift hele røgalarmen.

Produktspecifikationer

Mærke Kidde
Modelnummer i12060
Strømkilde 120 Volts AC (Hardwired) with 9V Battery Backup
Sensortype Ionisering
Batteritype 9-volt Alkaline (included)
Kompatible enheder Up to 24 Kidde devices (interconnect system)
Dimensioner Cirka 11.9 x 6.3 x 6.2 tommer
Vægt Cirka 3 pund
Driftstemperatur Op til 100 grader Fahrenheit

Garanti og support

The Kidde i12060 smoke alarm comes with a 10 års begrænset garanti, covering defects in material and workmanship from the date of purchase.

For technical support, warranty claims, or further assistance, please refer to the official Kidde website or contact their customer service. You can also find a detailed User Guide in PDF format for additional information:

Download brugervejledning (PDF)

Relaterede dokumenter - i12060

Preview Kidde CUAC10YFEX-V kombineret røg- og kuliltealarm brugervejledning
Omfattende brugervejledning til Kidde CUAC10YFEX-V kombineret fotoelektrisk røg- og kuliltealarm. Lær om installation, betjening, sikkerhedsfunktioner, fejlfinding og vedligeholdelse af denne 120V fastforbundne alarm med 10 års batteribackup.
Preview Kidde SMAC10YFEX fotoelektrisk røgalarm brugervejledning
Denne brugervejledning indeholder omfattende instruktioner til Kidde SMAC10YFEX fotoelektrisk røgalarm, der dækker installation, betjening, test, fejlfinding, sikkerhedsretningslinjer og garantioplysninger til privat brug.
Preview Brugervejledning til Kidde SMACFEX fotoelektrisk røgalarm
This user guide provides essential information for the Kidde SMACFEX photoelectric smoke alarm, covering installation, operation, testing, troubleshooting, safety recommendations, and warranty details. Learn how to ensure optimal fire safety in your home with this hardwire interconnect smoke alarm.
Preview Kidde 30CUA10-V Kombineret Røg- og Kuliltealarm Brugervejledning
Omfattende brugervejledning til Kidde 30CUA10-V fastforbundet kombineret fotoelektrisk røg- og kuliltealarm med stemmeadvarsler og 10 års batteribackup. Lær om installation, betjening, fejlfinding og sikkerhed.
Preview Kidde 30CUA10 Combination Smoke and Carbon Monoxide Alarm User Guide
Comprehensive user guide for the Kidde 30CUA10 Combination Photoelectric Smoke and Carbon Monoxide Alarm with Hardwire Interconnect, covering installation, operation, testing, troubleshooting, safety, and warranty information.
Preview Brugervejledning til Kidde SMACFEX fotoelektrisk røgalarm
This user guide provides detailed instructions for the Kidde SMACFEX photoelectric smoke alarm with hardwire interconnect. It covers installation, operation, testing, troubleshooting, maintenance, and fire safety recommendations.