Intermatic T104R3

Intermatic T104R3 Metal Time Clock Brugermanual

Model: T104R3

Indledning

This manual provides detailed instructions for the installation, operation, and maintenance of your Intermatic T104R3 Metal Time Clock. Please read this manual thoroughly before attempting to install or operate the device to ensure safe and efficient use.

The Intermatic T104R3 is a robust 24-hour, 230V, Double-Pole Single-Throw (DPST) time clock designed for various applications requiring scheduled ON/OFF control of electrical loads. It comes enclosed in a durable metal case for protection.

Sikkerhedsoplysninger

WARNING: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse box before installation or servicing. Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.

  • Always ensure power is OFF before working on the timer or connected circuits.
  • Do not exceed the electrical ratings of the timer.
  • Denne enhed er beregnet til permanent installation.
  • Sørg for, at alle forbindelser er sikre og korrekt isolerede.
  • Do not use this device in wet locations unless specifically rated for such use and installed in a weatherproof enclosure.

Pakkens indhold

  • Intermatic T104R3 Metal Time Clock
  • Instruktionsmanual (dette dokument)
  • Mounting hardware (screws, anchors - typically included)

Opsætning og installation

The Intermatic T104R3 is designed for easy installation, but proper electrical knowledge is essential. If you are unsure, consult a qualified electrician.

1. Mounting the Time Clock

  1. Choose a suitable location for mounting the time clock. It should be easily accessible, protected from direct weather (unless installed in a weatherproof enclosure), and close to the electrical circuit it will control.
  2. Open the metal case by unlatching the cover.
  3. Using the mounting holes on the back of the enclosure, mark the desired drilling locations on the wall or mounting surface.
  4. Drill pilot holes and secure the enclosure using appropriate screws and anchors. Ensure the enclosure is level and securely fastened.

2. Ledningsinstruktioner

IMPORTANT: Ensure power is OFF at the main circuit breaker before proceeding with any wiring.

Intermatic T104R3 Time Clock internal view med ledningsterminaler

Figur 1: Intern view of the Intermatic T104R3 showing the timer mechanism and wiring terminals. Note the "LINE" and "LOAD" connections, and the manual override switch.

  1. Locate the wiring terminals inside the time clock. You will typically find terminals labeled "LINE" (for incoming power) and "LOAD" (for outgoing power to the device being controlled). For the T104R3, which is DPST, there will be two "LINE" terminals and two "LOAD" terminals.
  2. Connect the incoming 230V power supply wires to the "LINE" terminals. Ensure proper polarity if applicable (L1 to L1, L2 to L2).
  3. Connect the wires leading to the electrical load (e.g., pump, lighting) to the "LOAD" terminals.
  4. Ensure all wire connections are tight and secure. Use appropriate wire gauges for the current draw.
  5. After wiring, carefully close the metal case, ensuring no wires are pinched.

Betjeningsvejledning

Once installed and wired, the Intermatic T104R3 is ready for programming.

1. Indstilling af det aktuelle klokkeslæt

  1. Restore power to the time clock at the circuit breaker.
  2. Rotate the large yellow dial clockwise until the current time of day aligns with the "TIME" arrow or indicator on the timer mechanism. The dial represents a 24-hour cycle.

2. Programmering af tænd/sluk-cyklusser

The T104R3 uses "trippers" or "pins" on the dial to set ON and OFF times. It has 3 settings, implying it can handle multiple ON/OFF cycles.

  • ON Trippers: These are typically green or silver and are inserted into the dial at the desired time for the connected device to turn ON.
  • OFF Trippers: These are typically red or black and are inserted into the dial at the desired time for the connected device to turn OFF.
  1. Insert the ON tripper into the slot on the dial corresponding to the desired ON time.
  2. Insert the OFF tripper into the slot on the dial corresponding to the desired OFF time.
  3. You can set multiple ON/OFF cycles throughout the 24-hour period by adding more trippers. Ensure there is at least one ON and one OFF tripper for each cycle.

3. Manuel tilsidesættelse

The T104R3 typically includes a manual override switch (often a lever or button) that allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Locate the "MANUAL" switch on the timer mechanism. Moving it to "ON" or "OFF" will override the current program until the next programmed event occurs.

Opretholdelse

The Intermatic T104R3 is designed for long-term, reliable operation with minimal maintenance.

  • Periodisk eftersyn: Annually inspect the time clock for any signs of wear, damage, or loose connections. Ensure the enclosure is free from dust, debris, or moisture.
  • Rensning: If necessary, gently wipe the exterior of the case with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure the power is disconnected before cleaning.
  • Tidsnøjagtighed: Periodically check if the time clock is keeping accurate time. Minor adjustments to the current time setting may be needed over long periods.

Fejlfinding

ProblemMulig årsagLøsning
Time clock not operating / no power.No power to the unit; tripped circuit breaker; loose wiring.Check circuit breaker and reset if tripped. Verify power supply at the terminals with a multimeter (CAUTION: High Voltage). Ensure all wiring connections are secure.
Device not turning ON/OFF at programmed times.Incorrect tripper placement; manual override engaged; incorrect current time setting.Verify ON/OFF trippers are correctly positioned on the dial. Check if the manual override switch is in the desired automatic position. Ensure the current time is accurately set.
Timer dial not rotating.Motor failure; obstruction.Ensure power is supplied to the unit. Check for any physical obstructions preventing the dial from rotating. If the motor is faulty, the unit may require professional servicing or replacement.

Specifikationer

  • Model: T104R3
  • Mærke: Intermatic
  • Voltage: 230V
  • Switch Type: Double-Pole Single-Throw (DPST)
  • Cyklus: 24 timer
  • Materiale: Metal (etui)
  • Produktdimensioner: 3.63" D x 6.5" B x 10.13" H
  • Antal indstillinger: 3 (referring to tripper capacity)
  • Farve: Multicolor (referring to components, case is typically beige/grey)

Garanti og support

Intermatic products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your product or visit the official Intermatic webwebsted. Behold din købskvittering som købsbevis i tilfælde af garantikrav.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic Customer Service. Contact information can typically be found on the manufacturer's webwebstedet eller på produktemballagen.

You can visit the official Intermatic Store on Amazon for more products and information: Intermatic Amazon Store

Relaterede dokumenter - T104R3

Preview Installations- og opsætningsvejledning til Intermatic ET2705-serien af ​​elektronisk 7-dages tidsafbryder
Omfattende installations-, opsætnings- og programmeringsvejledning til Intermatic ET2705, ET2705CR og ET2705CP elektroniske 1-kreds 7-dages tidsafbrydere. Dækker ledningsføring, indledende opsætning, planlægning, sommertidskonfiguration, USB-dataoverførsel og fejlfinding.
Preview Intermatic Digi 42-seriens elektroniske tidsafbryder, brugsanvisning
Betjeningsvejledning til Intermatic Digi 42-serien af ​​elektroniske tidsafbrydere, der dækker installation, programmering og fejlfinding for 24-timers og 7-dages tidsplaner.
Preview Intermatic ET1100-serien af ​​elektroniske tidsafbrydere: Funktioner, specifikationer og modeller
Detaljeret information om Intermatic ET1100-seriens 24-timers elektroniske tidsafbrydere, herunder funktioner, tekniske specifikationer, kontaktklassificeringer, kapslingsmuligheder og modelvariationer for præcis belastningskontrol.
Preview Installations- og servicemanual til Intermatic P7000ME-serien af ​​elektroniske tidsstyringer
Denne manual indeholder detaljerede instruktioner til installation, betjening og service af Intermatic P7000ME-seriens elektroniske tidsstyringer, inklusive modellerne P7101ME, P7102ME og P7103ME. Den dækker sikkerhedsforanstaltninger, specifikationer, ledningsdiagrammer, programmering og fejlfinding for pålidelig styring af apparater og udstyr.
Preview Installationsvejledning til Intermatic helplastik regntæt tidsafbryderkabinet
Detaljeret installationsvejledning til Intermatics regntætte tidsafbryderkabinet i helplast, der dækker montering af kabinet, rørtilslutninger og jordingskrav i henhold til den nationale elforskrift.
Preview Intermatic PE20000 serie pool/spa udstyrs kontrolpanel installations-, betjenings- og servicemanual
Omfattende vejledning til installation, betjening og service af Intermatic PE20000-seriens pool-/spaudstyrskontrolpanel med det digitale P1353ME-tidsur. Indeholder sikkerhedsinstruktioner, ledningsdiagrammer, driftsprocedurer og fejlfinding.