Produkt overview
The Cooper-Atkins 31901-K is a Type-K thermocouple needle probe designed for precise temperature measurement in various industrial applications. It features a durable silicone-jacketed cable and a robust nylon handle, ensuring reliability and longevity in demanding environments.

Image: The Cooper-Atkins 31901-K thermocouple needle probe, showing the needle, handle, cable, and Type-K connector.
Nøglefunktioner
- Type-K Thermocouple: Specifically designed for accurate temperature readings in industrial settings.
- Bredt temperaturområde: Measures temperatures from -40 to +400 degrees F (-40 to +205 degrees C).
- Optimal Probe Length: The probe measures 4 inches, suitable for various applications.
- Hurtig responstid: Achieves readings in approximately 4 seconds when immersed in liquid.
- Holdbart kabel: Silicone-jacketed cable designed to withstand temperatures up to 400 degrees F (205 degrees C).
Pakkens indhold
Når du åbner pakken, skal du kontrollere, at alle komponenter er til stede og ubeskadigede:
- 1 x Cooper-Atkins 31901-K Thermocouple Needle Probe Unit
- 1 x Instruktionsvejledning
Opsætningsinstruktioner
Follow these steps to prepare your thermocouple needle probe for use:
- Inspect the Probe: Before each use, visually inspect the probe for any signs of damage to the needle, handle, or cable. Ensure the silicone jacket is intact.
- Tilslut til måler: Connect the Type-K thermocouple connector (yellow plug) of the probe to a compatible Type-K thermocouple thermometer or data logger. Ensure a secure and firm connection.
- Tænd enhed: Turn on your temperature measurement device and allow it to stabilize according to its own instruction manual.

Image: The thermocouple probe with its Type-K connector, ready to be plugged into a compatible device.
Betjeningsvejledning
The Cooper-Atkins 31901-K probe is designed for direct contact temperature measurement. Always ensure safe handling practices.
- Forberedelse til måling: Ensure the probe tip is clean and free from debris. For liquid measurements, ensure the liquid is well-mixed for accurate readings.
- Indsæt sonden: Carefully insert the needle probe into the substance or material whose temperature you wish to measure. For liquids, ensure the tip is fully submerged. For semi-solids, insert the probe deep enough to ensure the sensing junction is fully within the material.
- Aflæs temperatur: Observe the temperature reading on your connected thermometer or data logger. Allow a few seconds for the reading to stabilize, especially in liquids, due to the 4-second response time.
- Fjern sonde: Once the reading is taken, carefully withdraw the probe from the substance.

Billede: Et nærbillede view of the needle tip and handle of the Cooper-Atkins 31901-K probe, highlighting its design for insertion.
Pleje og vedligeholdelse
Proper care will extend the life and accuracy of your probe:
- Rensning: After each use, clean the probe needle and handle with a damp cloth and mild detergent. Rinse thoroughly and dry completely. Do not immerse the entire probe or connector in water.
- Opbevaring: Store the probe in a clean, dry place, away from extreme temperatures and corrosive materials. Protect the needle tip from bending or damage.
- Inspektion: Regularly inspect the cable for cuts, abrasions, or kinks, and the connector for corrosion or damage.
- Kalibrering: While the probe itself does not require user calibration, ensure your connected thermometer is regularly calibrated according to its manufacturer's guidelines for accurate measurements.
Fejlfinding
If you encounter issues with your Cooper-Atkins 31901-K probe, consider the following common solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| No temperature reading or "Open" error | Loose connection to thermometer; damaged cable or connector; probe outside temperature range. | Ensure the probe is securely plugged into the thermometer. Inspect the cable and connector for visible damage. Verify the measured temperature is within the probe's specified range (-40 to +400°F). |
| Upræcise temperaturmålinger | Probe tip not fully immersed/inserted; thermometer calibration issue; external interference. | Ensure the probe tip is properly positioned within the substance. Check the calibration of your thermometer. Move away from strong electromagnetic fields. |
| Langsom responstid | Probe tip not making good contact; substance not uniform in temperature. | Ensure firm contact or proper immersion. Stir liquids if possible to ensure uniform temperature. |
Tekniske specifikationer
| Attribut | Detalje |
|---|---|
| Modelnummer | 31901-K |
| Probtype | Type-K Thermocouple Needle Probe |
| Temperaturområde | -40°F til +400°F (-40°C til +205°C) |
| Probe Length | 4 tommer |
| Svartid | 4 seconds (in liquid) |
| Kabelmateriale | Silicone-jacketed |
| Håndtag Materiale | Molded Nylon |
| Produktdimensioner | 6 x 10 x 1 tommer |
| Produktets vægt | 2.56 ounce |
| Fabrikant | Cooper Atkins |
| Oprindelsesland | USA |
Garanti og support
Information regarding the specific warranty period and direct customer support contacts for the Cooper-Atkins 31901-K Thermocouple Needle Probe was not provided in the product data. For warranty claims, technical assistance, or service inquiries, please refer to the official Cooper-Atkins webwebstedet eller kontakt deres kundeserviceafdeling direkte. Gem din købskvittering som købsbevis.
Du kan også besøge Cooper-Atkins Store on Amazon for yderligere produktinformation og ressourcer.