1. Introduktion
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TCS NGV1011-0400 Intercom Accessory Control Unit. Please read this manual thoroughly before attempting to install or operate the device. Retain this document for future reference.
2. Sikkerhedsoplysninger
ADVARSEL: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect power before installation or maintenance.
- Sørg for, at alle lokale og nationale elektriske forskrifter følges under installationen.
- Udsæt ikke enheden for fugt eller ekstreme temperaturer.
- Bekræft korrekt voltage og strømstyrke før tilslutning af strøm.
- Always use appropriate tools and personal protective equipment.
3. Produktet er slutview
The TCS NGV1011-0400 is an accessory control unit designed for intercom systems, typically used with door stations. It functions as a power supply and control interface, converting AC input to DC output for system components.

Figure 1: TCS NGV1011-0400 Intercom Accessory Control Unit. This image displays the TCS NGV1011-0400 intercom accessory control unit. The front panel features the TCS logo, model number NGV1011-0400, and CE marking. Terminal blocks are visible at the top and bottom for electrical connections. The label indicates an output voltage of 26 V DC / 2.5 A and AC input terminals L, N, PE.
Nøglefunktioner:
- Designed for door station applications.
- Input bindtage: 230 V AC.
- Udgang Voltage: 26 V DC at 2.5 A.
- Integrated terminal blocks for secure wiring.
4. Opsætning og installation
Before beginning installation, ensure the main power supply is disconnected. The unit is designed for DIN rail mounting within an electrical enclosure.
4.1 Ledningsforbindelser:
Refer to the product label and Figure 1 for terminal identification.
- AC Input (Terminals L, N, PE): Connect the 230 V AC mains power supply to these terminals.
- L (Line): Tilslut den strømførende ledning.
- N (neutral): Tilslut den neutrale ledning.
- PE (Beskyttende jordledning): Connect to the protective earth ground.
- DC Output (Terminals 29, 31): These terminals provide the 26 V DC / 2.5 A output for the intercom system components.
- Terminal 29: Connect to the negative (-) DC input of the intercom component.
- Terminal 31: Connect to the positive (+) DC input of the intercom component.
- Control Output (Terminal 36): This terminal is typically used for control signals, such as activating a door opener or a light. Consult your intercom system's specific wiring diagram for its function.
After all connections are made, double-check wiring for correctness and secureness before restoring power.
5. Betjeningsvejledning
The TCS NGV1011-0400 operates automatically once correctly installed and powered. It provides the necessary power and control signals to the connected intercom system. There are no user-adjustable controls on the unit itself.
- Tænd: Once AC power is supplied to the L, N, PE terminals, the unit will power on and provide 26 V DC output.
- Systemintegration: The functionality of the NGV1011-0400 is integrated with the overall intercom system. Refer to the manual of your specific intercom system for operational details.
6. Vedligeholdelse
The TCS NGV1011-0400 is designed for minimal maintenance. Regular inspections are recommended to ensure optimal performance.
- Rensning: Disconnect power before cleaning. Use a soft, dry cloth to wipe the exterior of the unit. Do not use liquid cleaners or solvents.
- Inspektion: Periodically check all wiring connections for tightness and signs of wear or damage. Ensure the unit is free from dust accumulation, which can impede cooling.
- Miljøforhold: Sørg for, at driftsmiljøet forbliver inden for de angivne temperatur- og fugtighedsintervaller.
7. Fejlfinding
If the intercom system is not functioning correctly, consider the following troubleshooting steps related to the NGV1011-0400 unit:
- Ingen strømudgang:
- Verify that the 230 V AC mains power supply is active and correctly connected to terminals L, N, and PE.
- Check for tripped circuit breakers or blown fuses in the main electrical panel.
- Ensure all DC output connections (Terminals 29, 31) are secure and correctly polarized.
- Intermitterende drift:
- Undersøg alle ledninger for løse forbindelser eller beskadiget isolering.
- Ensure the unit is not overheating due to inadequate ventilation or excessive load.
- If problems persist after performing these checks, contact qualified service personnel. Do not attempt to repair the unit yourself.
8. Specifikationer
| Parameter | Værdi |
|---|---|
| Mærke | TCS |
| Modelnummer | NGV1011-0400 |
| Anvendelse | Door Station Accessory / Intercom Control Unit |
| AC -indgang Voltage | 230 V |
| Frekvens | 50 Hz |
| DC Output Voltage / Strøm | 26 V DC / 2.5 A. |
| Varens vægt | 200 gram |
9. Garantioplysninger
Warranty information for the TCS NGV1011-0400 is not provided in the available product data. Please refer to your purchase documentation or contact your retailer for details regarding warranty coverage.
10. Support
Specific support contact information is not provided in the available product data. For technical assistance or service, please contact the retailer where the product was purchased or visit the official TCS website for general support resources.