1. Introduktion
The OPTIMA YellowTop high-performance AGM battery is engineered for vehicles with high electrical demands, offering both premium cranking power for reliable starts and unparalleled cycling capability for deep-cycle applications. Its advanced Sealed Absorbed Glass Mat (AGM) technology ensures a maintenance-free experience and superior performance in various conditions.
Nøglefunktioner:
- Design med dobbelt formål: Provides strong starting power and deep-cycle performance for accessory-loaded vehicles.
- SpiralCell-teknologi: Utilizes 99.99% pure lead plates wound into spirals, offering superior power delivery and extreme vibration resistance.
- Vedligeholdelsesfri: Sealed design eliminates the need for water additions and reduces corrosion.
- Høj omdrejningshastighed Amps: Delivers 750 Cold Cranking Amps (CCA) for reliable starting in cold weather.
- Forlænget levetid: Up to 3 times longer life compared to standard flooded batteries.
- Alsidig montering: Designed for flexible installation.

2. Opsætning og installation
Proper installation is crucial for the safety and performance of your OPTIMA YellowTop battery. Always follow your vehicle manufacturer's guidelines for battery replacement and safety precautions. It is recommended to have battery installation performed by a qualified professional.
Sikkerhedsforanstaltninger:
- Brug passende personlige værnemidler, herunder sikkerhedsbriller og handsker.
- Ensure the vehicle's ignition is off and all electrical accessories are disconnected.
- Disconnect the negative (-) terminal first, followed by the positive (+) terminal.
- Avoid short-circuiting the battery terminals with tools or other metal objects.
- Hold gnister, flammer og rygende materialer væk fra batteriet.
- Ensure adequate ventilation during installation and charging.
Installationstrin:
- Carefully remove the old battery from the battery tray.
- Clean the battery tray and cable terminals to remove any corrosion or debris.
- Place the OPTIMA YellowTop battery securely in the battery tray.
- Connect the positive (+) cable to the positive (+) battery terminal first.
- Connect the negative (-) cable to the negative (-) battery terminal last.
- Sørg for, at alle forbindelser er tætte og sikre.
- Verify proper fitment and secure the battery with any hold-down clamps.

Understanding Battery Venting:
While OPTIMA AGM batteries are sealed and maintenance-free, all lead-acid batteries, including AGM, have provisions for venting gases in severe overcharging situations. This is a safety feature to prevent pressure buildup. Ensure the battery's vent ports are not obstructed during installation.
3. Driftsvejledninger
The OPTIMA YellowTop battery is designed for optimal performance in both starting and deep-cycle applications. To maximize its lifespan and ensure consistent power delivery, adhere to the following guidelines:
- Regelmæssig brug: For vehicles that are not used daily, consider using a compatible battery maintainer to keep the battery fully charged.
- Undgå dyb udflåd: While the YellowTop is a deep-cycle battery, repeatedly discharging it below 10.5 volts can shorten its lifespan.
- Korrekt opladning: Use a charger designed for AGM batteries. Avoid using chargers that are not regulated or that deliver excessive voltage.
- Accessory Load Management: Be mindful of the electrical load from accessories, especially when the engine is off, to prevent excessive discharge.
4. Vedligeholdelse
One of the primary benefits of the OPTIMA YellowTop AGM battery is its maintenance-free design. Unlike traditional flooded batteries, it does not require water additions. However, some general care practices will help ensure its longevity:
- Hold terminalerne rene: Periodically inspect battery terminals for corrosion and clean them if necessary using a wire brush and a mixture of baking soda and water. Rinse with clean water and dry thoroughly.
- Tjek forbindelser: Ensure all cable connections to the battery terminals remain tight and secure. Loose connections can lead to poor performance and heat buildup.
- Battery Tray Inspection: Check the battery tray for any signs of damage or corrosion. Ensure the battery is securely held in place to prevent vibration damage.
- Opbevaring: If storing the battery for an extended period, ensure it is fully charged and then disconnect it from the vehicle. Store in a cool, dry place and periodically check its voltage, recharging if it drops below 12.6 volts.
5. Fejlfinding
If you experience issues with your OPTIMA YellowTop battery, consider the following common problems and solutions. For complex issues, consult a qualified automotive technician.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren drejer langsomt eller slet ikke | Discharged battery, loose/corroded connections, faulty starter/alternator. | Charge battery with an AGM-compatible charger. Clean and tighten terminals. Test charging system and starter. |
| Batteri holder ikke opladning | Parasitic drain, faulty charging system, aged battery, internal cell damage. | Check for parasitic drains. Test alternator output. If battery is old, consider replacement. Consult professional for internal issues. |
| Korrosion på terminaler | Loose connections, acid leakage (rare for AGM), environmental factors. | Clean terminals thoroughly. Ensure connections are tight. Apply anti-corrosion spray. |
| Batterikassen ser hævet eller beskadiget ud | Overopladning, intern skade. | Immediately disconnect the battery if safe to do so. Do NOT attempt to charge or use. This indicates a serious internal fault. Replace the battery. |
6. Specifikationer
Detailed technical specifications for the OPTIMA YellowTop D34/78 battery:
| Attribut | Værdi |
|---|---|
| Voltage | 12-volt |
| Kold cranking Amps (CCA) | 750 CCA |
| C20 Kapacitet | 55 AH |
| Reservekapacitet | 120 minutter |
| Dimensioner (L x B x H) | 10" x 6 7/8" x 7 13/16" (254mm x 175mm x 200mm) |
| Vægt | 43.5 pund |
| Terminaltype | Dual SAE & GM Terminals |
| Modelnummer | 9014-045 (OEM Part Number: 8014-045) |
| UPC | 721112767383, 811405000454 osv. |
| Oprindelsesland | Mexico |
Hvad er der i æsken:
- SEALED LEAD ACID BATTERY - GROUP 3478 YELLOW TOP DUAL PURPOSE
7. Garantioplysninger
OPTIMA Batteries offers a 3-Year FREE Replacement warranty with proof of purchase for this product. For detailed warranty terms and conditions, including registration and claim procedures, please refer to the official OPTIMA Batteries webwebsted eller kontakt kundeservice.
Udvidede beskyttelsesplaner kan også købes:
- 2-årig beskyttelsesplan
- 3-årig beskyttelsesplan
Gem venligst din købsbevis i tilfælde af garantikrav.
8. Kundesupport
For further assistance, technical support, or warranty inquiries, please contact OPTIMA Batteries customer service:
- Kundeservice telefon: 1-888-867-8462
- Officiel Webwebsted: optimabatteries.com
- Brugermanual (PDF): Download PDF
- Sikkerhedsoplysninger (PDF): Download PDF
You can also visit the official OPTIMA Store for more product information and resources: OPTIMA Store on Amazon