1. Introduktion

The Dickson TM320 is a versatile data logger designed to accurately monitor and record temperature and humidity levels. Featuring a large display for real-time readings, audio/visual alarms, and convenient data transfer options via USB and flash card, it provides essential environmental monitoring for various applications. Its user-friendly design ensures ease of use and reliable performance.

  • USB Enabled Download: Easily transfer recorded data to a computer.
  • Flash Memory Data Transfer Capability: Utilize flash cards for convenient data retrieval.
  • Jumbo Display: Clear and easy-to-read real-time measurements.
  • Nem at bruge: Intuitive interface for straightforward operation.

2. Sikkerhedsoplysninger

Please read all safety instructions before operating the device. Failure to do so may result in damage to the device or personal injury.

  • Do not expose the device to extreme temperatures outside its specified operating range.
  • Avoid direct contact with water or high humidity environments beyond the non-condensing range.
  • Brug kun de angivne strømkilder og tilbehør.
  • Forsøg ikke at åbne eller reparere enheden selv. Overlad al service til kvalificeret personale.
  • Opbevares utilgængeligt for børn.

3. Pakkens indhold

Bekræft at alle varer er til stede i pakken:

  • Dickson TM320 Data Logger
  • Instruktionsmanual (dette dokument)
  • USB-kabel (sælges muligvis separat)
  • SD Card (may be sold separately)
  • Batteries (may be pre-installed or included)

4. Produktet er slutview

Front view of Dickson TM320 Data Logger with display showing '0.0' and battery indicator.

Figur 4.1: Forside View. Shows the large digital display, 'DICKSON' branding, and three control buttons: MIN/MAX, ALARM, and SAVE.

Side view of Dickson TM320 Data Logger showing USB port, sensor input, and ventilation slots.

Figur 4.2: Side View with Ports. Illustrates the mini-USB port for data transfer and external sensor input jacks, along with ventilation for internal sensors.

Tilbage view of Dickson TM320 Data Logger showing battery compartment and mounting holes.

Figur 4.3: Tilbage View. Displays the battery compartment cover and keyhole slots for wall mounting.

Top view of Dickson TM320 Data Logger showing the SD card slot.

Figur 4.4: Øverst View. Shows the slot for inserting an SD card for data storage and transfer.

5. Opsætning

5.1. Batteriinstallation

  1. Find batterirummet på bagsiden af ​​enheden (se figur 4.3).
  2. Skub batteridækslet åbent.
  3. Insert the required batteries (typically AA or AAA, check compartment for type) ensuring correct polarity (+/-).
  4. Luk batteridækslet forsvarligt.

5.2. Første opstart

The device should power on automatically once batteries are installed. The display will illuminate, showing current readings or a startup sequence.

5.3. Montering af enheden

The TM320 can be placed on a flat surface or mounted on a wall:

  • Overfladeplacering: Ensure the device is placed on a stable, level surface away from direct heat sources or extreme drafts.
  • Vægmontering: Use appropriate screws (not included) with the keyhole slots on the back of the device (refer to Figure 4.3) to secure it to a wall. Ensure it is mounted in a location representative of the environment you wish to monitor.

6. Betjening

6.1. Forståelse af displayet

The jumbo display provides real-time information:

  • Nuværende læsning: Shows the live temperature or humidity value.
  • Enheder: Indicates Fahrenheit (F) or Celsius (C) for temperature, and %RH for humidity.
  • Batteriindikator: Viser den resterende batterilevetid.
  • CH (kanal): Indicates which channel is currently displayed (e.g., CH 1 for temperature, CH 2 for humidity).

6.2. Knapfunktioner

  • MIN/MAX-knap: Press to cycle through minimum, maximum, and current readings for both temperature and humidity. Hold to reset min/max values.
  • ALARM knap: Tryk for at view current alarm settings. Hold to enter alarm setting mode (refer to section 6.4).
  • GEM knap: Press to manually save a data point.

6.3. Datalogning

The TM320 automatically logs data at a pre-set interval. Data can be viewed on the display or downloaded to a computer.

6.4. Indstilling af alarmer

The device features audio/visual alarms for out-of-range conditions.

  1. Tryk og hold på ALARM button until the alarm setting mode is activated.
  2. Brug MIN / MAX button to navigate between temperature and humidity alarm settings (high/low).
  3. Brug SPARE button to adjust the alarm threshold values.
  4. Trykke ALARM again to confirm and exit the setting mode.

6.5. Data Download (USB)

  1. Connect the TM320 to your computer using a compatible USB cable (refer to Figure 4.2 for port location).
  2. The device should be recognized as a removable storage device or require specific Dickson software (refer to manufacturer's webwebsted for software).
  3. Follow the software instructions to download and analyze the logged data.

6.6. Data Transfer (Flash Card)

If your model supports flash card data recovery:

  1. Insert a compatible SD card into the SD card slot (refer to Figure 4.4).
  2. The device may automatically transfer data or require a specific button press (consult software/manual for details).
  3. Remove the SD card and insert it into a computer's card reader to access the data.

7. Vedligeholdelse

7.1. Rensning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the sensor vents or ports.

7.2. Udskiftning af batteri

Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 5.1.

7.3. Opbevaring

When not in use for extended periods, remove the batteries and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Fejlfinding

ProblemMulig årsagLøsning
Enheden tænder ikke.Døde eller forkert installerede batterier.Kontroller batteripolariteten; udskift med nye batterier.
No data is being logged.Device not powered on; memory full; logging paused.Ensure device is on; download data to clear memory; check software settings for logging status.
Display shows 'Err' or abnormal readings.Sensor malfunction; out of range conditions.Move device to a stable environment; contact support if error persists.
Cannot download data via USB.Incorrect cable; driver issue; software not installed.Ensure correct USB cable; install necessary drivers/software from Dickson webwebsted.
Alarmen lyder ikke.Alarm disabled; volume too low; thresholds set incorrectly.Check alarm settings (Section 6.4); ensure alarm is enabled and thresholds are appropriate.

9. Specifikationer

FeatureDetalje
ModelnummerTM320
Temperaturområde-4 til 158°F (-20 til 70°C)
Fugtighedsområde0-95 % RH (ikke-kondenserende)
FabrikantDickson Unigage Inc.
Produktdimensioner19.56 x 16.51 x 8.89 cm (7.7 x 6.5 x 3.5 tommer)
Produktets vægt385.55 g (0.85 lbs)
DataoverførselUSB, Flash Card (SD)
ViseJumbo LCD

10. Garanti og support

This product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dickson website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Dickson customer service through their official channels.

Dickson Official Webwebsted: www.dicksonlogger.com

Relaterede dokumenter - TM320

Preview Dickson TSB/TWE/TWP berøringsskærms datalogger hurtigstartguide
En hurtigstartguide til Dickson TSB/TWE/TWP touchscreen-dataloggeren, der dækker opsætning, tilslutning via Ethernet eller Wi-Fi og integration med DicksonOne-platformen.
Preview DICKSON Processlogger HT350: Brugervejledning og opsætning
Omfattende vejledning til opsætning, brug og fejlfinding af DICKSON Process Logger HT350, inklusive softwareinstallation, datalogning og garantioplysninger.
Preview Dickson SP125, SP175, TP125 Miljødatalogger Manual
Omfattende brugermanual til Dickson SP125, SP175 og TP125 miljødataloggere. Dækker funktioner, specifikationer, kalibrering, DicksonWare-software og betjening for nøjagtig dataregistrering og overvågning.
Preview DBL Datalogger Lynstartguide - Dickson
Lynvejledning til Dickson DBL-dataloggeren, der dækker opsætning, konfiguration med DicksonWare 2.0, logning, datadownload og firmwareinformation.
Preview TSB Touchscreen Datalogger Manual - Dickson
Brugermanual til Dickson TSB Touchscreen Data Logger, der beskriver opsætning, datadownload via USB, lagring af skærmbilleder og konfiguration af enhedsindstillinger som alarmer, grafvisning og skærmlås.
Preview Dickson DWE internetforbundet datalogger – hurtigstartguide
Denne hurtigstartvejledning indeholder instruktioner til opsætning og tilslutning af den internetforbundne Dickson DWE datalogger, så brugerne kan komme i gang med Ethernet- eller Wi-Fi-forbindelse og registrere deres enhed på DicksonOne-platformen til online datamåling. viewog alarmkonfiguration.