Zoeller 105-0001

Zoeller 105-0001 sumppumpe brugsanvisning

Model: 105-0001

Mærke: Zoeller

Indledning

This manual provides detailed instructions for the installation, operation, and maintenance of your Zoeller 105-0001 Sump Pump. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

Sikkerhedsoplysninger

Generelle sikkerhedsforanstaltninger

Opsætning

Udpakning og inspektion

Unpack all components and inspect for any shipping damage. Report any damage to the carrier immediately.

Komponenter overview

The Zoeller 105-0001 package includes:

Installationstrin

1. Basin Placering

Place the collection basin in the desired location, ensuring it is level and stable. The basin should be positioned to effectively collect water from the intended drainage area.

2. Installation af pumpe

Carefully lower the sump pump unit into the collection basin. Ensure the pump is seated securely at the bottom of the basin.

Zoeller 105-0001 Sump Pump with basin and check valve

This image displays the complete Zoeller 105-0001 Sump Pump package, including the green cast iron pump unit, the black collection basin, and the green check valve with connecting pipes.

3. VVS-tilslutninger

Connect the discharge pipe to the pump's outlet. Install the check valve in the discharge line to prevent backflow. Ensure all connections are tight and leak-free. The discharge pipe should be 1-1/2" NPT.

4. Udluftning

Proper venting is crucial for efficient operation. Connect a vent line to the basin as per local plumbing codes. This allows air to escape as the basin fills and prevents airlock.

5. Elektrisk tilslutning

Connect the pump to a grounded 115V/1 Ph electrical outlet. The pump comes with a 9 ft. UL listed 3-wire cord and plug. Ensure the circuit is protected by a Ground Fault Circuit Interrupter (GFCI).

Betjeningsvejledning

The Zoeller 105-0001 Sump Pump features an automatic, float-operated mechanical switch. The pump will activate automatically when the water level in the basin rises and lifts the float, and will turn off once the water level drops and the float returns to its lower position.

Indledende opstart

After installation, fill the basin with water to test the pump's operation. Observe the pump activating, discharging water, and deactivating. Check for any leaks or unusual noises.

Opretholdelse

Regelmæssig vedligeholdelse sikrer din sumppumpes levetid og pålidelige drift.

Månedlige kontrol

Årlig rengøring

Disconnect power. Remove the pump from the basin. Clean any debris from the pump's intake and the basin. The non-clogging vortex impeller is designed to pass 1/2" spherical solids and laundry lint, but periodic cleaning is still recommended.

Fejlfinding

Fælles problemer og løsninger

ProblemMulig årsagLøsning
Pumpen kører ikke.No power; tripped GFCI; float switch obstructed.Check power supply; reset GFCI; clear float switch obstruction.
Pumpen kører, men pumper ikke vand.Air lock; clogged intake/discharge; check valve stuck closed.Relieve air lock; clear clogs; inspect check valve.
Pumpen kører kontinuerligt.Float switch stuck open; check valve leaking.Clear float switch; inspect/replace check valve.

Specifikationer

Garanti

The Zoeller 105-0001 Sump Pump typically comes with a 1-year warranty. Please refer to the warranty card included with your product for specific terms and conditions. For extended protection, consider available protection plans.

Støtte

For technical assistance, replacement parts, or warranty claims, please contact Zoeller customer support. You may also find additional resources and FAQs on the official Zoeller webwebsted.

Officiel installationsmanual (PDF): Download her

Relaterede dokumenter - 105-0001

Preview Zoeller 900-serien præmonterede sumppumpesystemer - Nem installation
Oplev Zoeller 900-seriens præmonterede sumppumpesystemer, designet til hurtig og nem installation. Funktionerne omfatter automatisk flydeafbryder, holdbar støbejernspumpe og forskellige basin options for residential and commercial use. Learn about model specifications and performance.
Preview Zoeller APak Alarmsystemer: Overvågning af højt vandniveau og sumppumpe
Lær om Zoellers APak-alarmsystemer, herunder indendørs- og udendørsmodeller med Z Control®-funktioner til pålidelig notifikation om højt vandniveau, advarsler om pumpefejl og fjernovervågning.
Preview Zoeller AquaNot 585 Battery Backup Pedestal Sump Pump Technical Data Sheet
Detailed technical specifications and performance data for the Zoeller AquaNot 585 Battery Backup Pedestal Sump Pump system, including product features, battery requirements, and installation cautions.
Preview Installationsvejledning til Zoeller Aquanot Fit 508/53/63/98 sumppumpesystem
Omfattende installationsvejledning til Zoeller Aquanot Fit 508/53/63/98 præmonteret sumppumpesystem med 12V DC batteribackup. Lær om opsætning, betjening og vedligeholdelse.
Preview Zoeller Drain Pump Series Technical Data Sheet
Technical data sheet for Zoeller Drain Pump Series, including models 104, 105, 106, 110, 115, 120, 131, and 132. Provides specifications, performance curves, and model comparisons for various drain pump applications.
Preview Zoeller Basement Sentry 12 Volt Backup Sump Pump System Technical Data Sheet
Technical data sheet for the Zoeller Basement Sentry 12 Volt Backup Sump Pump System, including product specifications, pump details, DC charger information, LED indicators, float switch, LCD screen, buttons, battery case, auxiliary alarm contact, technology, fittings, performance data, and warranty information.