Indledning
This manual provides detailed instructions for the installation, operation, and maintenance of your Zoeller 105-0001 Sump Pump. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.
Sikkerhedsoplysninger
Generelle sikkerhedsforanstaltninger
- Afbryd altid strømmen før servicering.
- Brug ikke pumpen tør.
- Sørg for korrekt jording.
- Hold hænderne væk fra bevægelige dele.
- Brug passende personlige værnemidler (PPE).
Opsætning
Udpakning og inspektion
Unpack all components and inspect for any shipping damage. Report any damage to the carrier immediately.
Komponenter overview
The Zoeller 105-0001 package includes:
- Sump Pump Unit
- Collection Basin
- Kontraventil
- Necessary Fittings and Hardware
Installationstrin
1. Basin Placering
Place the collection basin in the desired location, ensuring it is level and stable. The basin should be positioned to effectively collect water from the intended drainage area.
2. Installation af pumpe
Carefully lower the sump pump unit into the collection basin. Ensure the pump is seated securely at the bottom of the basin.

This image displays the complete Zoeller 105-0001 Sump Pump package, including the green cast iron pump unit, the black collection basin, and the green check valve with connecting pipes.
3. VVS-tilslutninger
Connect the discharge pipe to the pump's outlet. Install the check valve in the discharge line to prevent backflow. Ensure all connections are tight and leak-free. The discharge pipe should be 1-1/2" NPT.
4. Udluftning
Proper venting is crucial for efficient operation. Connect a vent line to the basin as per local plumbing codes. This allows air to escape as the basin fills and prevents airlock.
5. Elektrisk tilslutning
Connect the pump to a grounded 115V/1 Ph electrical outlet. The pump comes with a 9 ft. UL listed 3-wire cord and plug. Ensure the circuit is protected by a Ground Fault Circuit Interrupter (GFCI).
Betjeningsvejledning
The Zoeller 105-0001 Sump Pump features an automatic, float-operated mechanical switch. The pump will activate automatically when the water level in the basin rises and lifts the float, and will turn off once the water level drops and the float returns to its lower position.
Indledende opstart
After installation, fill the basin with water to test the pump's operation. Observe the pump activating, discharging water, and deactivating. Check for any leaks or unusual noises.
Opretholdelse
Regelmæssig vedligeholdelse sikrer din sumppumpes levetid og pålidelige drift.
Månedlige kontrol
- Verify the float switch moves freely and is not obstructed.
- Pour water into the basin to ensure the pump cycles on and off correctly.
- Undersøg netledningen for eventuelle skader.
Årlig rengøring
Disconnect power. Remove the pump from the basin. Clean any debris from the pump's intake and the basin. The non-clogging vortex impeller is designed to pass 1/2" spherical solids and laundry lint, but periodic cleaning is still recommended.
Fejlfinding
Fælles problemer og løsninger
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pumpen kører ikke. | No power; tripped GFCI; float switch obstructed. | Check power supply; reset GFCI; clear float switch obstruction. |
| Pumpen kører, men pumper ikke vand. | Air lock; clogged intake/discharge; check valve stuck closed. | Relieve air lock; clear clogs; inspect check valve. |
| Pumpen kører kontinuerligt. | Float switch stuck open; check valve leaking. | Clear float switch; inspect/replace check valve. |
Specifikationer
- Model: 105-0001
- Mærke: Zoeller
- Strømkilde: AC/DC
- Voltage: 115 volt (AC)
- Hestekræfter: 0.5 HK
- Maksimal gennemstrømningshastighed: 43 gallon pr. Minut
- Udledningsstørrelse: 1-1/2" NPT
- Ledningslængde: 9 fod
- Varens vægt: 30 pund
- Produktdimensioner: 14.5 cm L x 14.5 cm B x 12.5 cm H
- Løbehjulstype: Ikke-tilstoppende hvirvel
- Switch Type: Automatic, float operated mechanical
Garanti
The Zoeller 105-0001 Sump Pump typically comes with a 1-year warranty. Please refer to the warranty card included with your product for specific terms and conditions. For extended protection, consider available protection plans.
Støtte
For technical assistance, replacement parts, or warranty claims, please contact Zoeller customer support. You may also find additional resources and FAQs on the official Zoeller webwebsted.
Officiel installationsmanual (PDF): Download her