This manual provides detailed instructions for the installation, operation, and maintenance of your Wallpad L3-BG-DIY modular switch and socket system. This system allows for flexible customization of electrical outlets and switches to suit various international standards and functional needs. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Produkt overview

The Wallpad L3-BG-DIY system features a range of modular components, including various types of switches, dimmers, fan controls, and international sockets (US, EU, French, Brazil, Italian, USB, Data, TV, Satellite). These modules are designed to be combined within standard frames to create custom wall plates.

Overview of various Wallpad DIY switch and socket modules
Figure 1: Assortment of Wallpad DIY switch and socket modules.

The system uses a modular sizing convention:

  • M (Module): Refers to the size unit of individual components.
  • Bande: Refers to the number of buttons on a switch. For example, a 1 Gang switch has 1 button, a 2 Gang switch has 2 buttons, and a 3 Gang switch has 3 buttons.
  • Vej: Describes how a switch controls a lamp.
    • 1 vejs: One switch controls one lamp.
    • 2 vejs: Two switches control one lamp together. Note that a 2-way switch can also function as a 1-way switch, but a 1-way switch cannot be used as a 2-way switch.
    • Mellemomskifter: Used in conjunction with two 2-way switches to control a single lamp from three or more locations.

Some switches include indicators: Switch A features a fluorescent indicator, while Switch B and Switch C are equipped with LED indicators.

Installation og opsætning

The Wallpad L3-BG-DIY system requires separate purchase of frames and individual functional modules. Ensure you have selected the appropriate frame size (e.g., 6M, 9M, 12M) and the desired modules before beginning installation.

Diagram showing the 6M frame dimensions of 118mm by 75mm
Figure 2: 6M frame dimensions (118mm x 75mm).
Diagram illustrating smart and adjustable screw distance for mounting
Figure 3: Smart and adjustable screw distance for mounting (80mm screw distance, 10mm side).

A standard rectangular mounting box is required for installation. The screw distance is adjustable for ease of fitting.

Montering Examples:

Example of a 6M frame assembled with various modules
Figur 4: Eksample of a 6M frame assembly.
Example of a 9M frame assembled with various modules
Figur 5: Eksample of a 9M frame assembly.
Example of a 12M frame assembled with various modules
Figur 6: Eksample of a 12M frame assembly.

Ledningsdiagrammer

Proper wiring is crucial for the safe and correct operation of your Wallpad modules. Always ensure power is disconnected before performing any wiring. Consult a qualified electrician if you are unsure about any steps.

Comprehensive wiring diagrams for power sockets, 1-way switches, 2-way switches, and intermediate switches
Figure 7: Detailed Wiring Diagrams for various modules.

Ledningsinstruktioner:

  • Strømstik: Connect the Null Wire (typically blue) to 'N', Ground Wire (typically green/yellow) to 'T', and Live Wire (typically red/brown) to 'L'.
  • 1-vejs switch: For controlling one lamp from one location. Connect the Live Wire to 'L' and the switched live to 'L1'.
  • 2-vejs switch: For controlling one lamp from two locations. Connect the main Live Wire to 'L' on the first switch. Connect 'L1' and 'L2' from the first switch to 'L1' and 'L2' on the second switch, respectively. The switched live to the lamp connects from 'L' on the second switch.
  • Mellemomskifter: For controlling one lamp from three or more locations. This requires two 2-way switches and one intermediate switch. The intermediate switch connects between the two 2-way switches, typically using connections LB1, LB2, L1, L2 as shown in the diagram.

Operation

Operating your Wallpad modules is straightforward:

  • Switches (1, 2, 3, 4 Gang): Press the button(s) to toggle the connected light or appliance on/off. Switches with fluorescent or LED indicators will illuminate when the switch is in the 'on' position.
  • Fan Dimmer: Rotate the knob or use the designated controls to adjust the speed of the connected fan.
  • Lysdæmperkontakt: Rotate the knob or use the designated controls to adjust the brightness of the connected light.
  • Sockets (US, EU, French, Brazil, Italian, Universal): Insert the appropriate plug into the socket to provide power to your devices.
  • USB Data Outlet: Connect your USB-compatible devices for charging.
  • Data/TV/Satellite Outlets: Connect the respective cables for network, television, or satellite signals.

Opretholdelse

To ensure the longevity and proper functioning of your Wallpad products, follow these maintenance guidelines:

  • Rensning: Use a soft, dry cloth to wipe the surface of the switches and sockets. For stubborn marks, a slightly damp cloth with mild soap can be used, followed by immediate drying. Avoid abrasive cleaners, solvents, or harsh chemicals, as these can damage the brushed aluminum finish or plastic components.
  • Sikkerhed: Always disconnect power to the circuit at the main breaker before cleaning or performing any maintenance that involves opening the wall plate or accessing wiring.
  • Inspektion: Periodically check for any loose connections, cracks, or damage to the modules or frame. If any damage is found, discontinue use and replace the affected component.

Fejlfinding

If you encounter issues with your Wallpad modular system, consider the following common problems and solutions:

  • Light/Appliance Not Turning On:
    • Kontroller, om afbryderen er udløst.
    • Ensure the light bulb or appliance is functional.
    • Verify that the switch is correctly wired according to the diagrams (see Figure 7).
    • For 2-way or intermediate switches, ensure all switches in the circuit are functioning correctly and wired in sequence.
  • Socket Not Providing Power:
    • Kontroller, om afbryderen er udløst.
    • Ensure the device being plugged in is functional.
    • Verify that the socket is correctly wired (Live, Neutral, Ground) according to the diagrams (see Figure 7).
  • Dimmer/Fan Control Not Working:
    • Ensure the connected light or fan is compatible with dimming/speed control.
    • Check wiring connections for the dimmer/fan control module.

If problems persist after checking these points, it is recommended to consult a qualified electrician.

Specifikationer

AttributDetalje
MærkenavnWallpad
ModelnummerL3-BG-DIY
OprindelseFastlandet Kina
CertificeringCE, RoHS
6M Frame Size118*75 mm
RammematerialeBørstet aluminium
Box NeededRectangular Box
Standard kompatibilitetAU, US, IL, Chile, EU, French, Brazil, Italian
FungereFree DIY Combination
Pakkedimensioner (L x B x H)11 cm x 11 cm x 11 cm
Pakkevægt0.15 kg

Brugertips

  • Modular Purchase: Remember that the frames and individual functional modules (keys) are sold separately. Ensure you purchase both the frame and the specific modules you need for your desired configuration.
  • 2-Way Switch Functionality: A 2-way switch can be used for both 1-way and 2-way control. However, a 1-way switch cannot be adapted for 2-way control. Plan your wiring accordingly.
  • Ledningspolaritet: Always ensure correct wiring polarity (Live, Neutral, Ground) for all modules, especially sockets, to prevent electrical hazards. If you encounter terms like 'false poles' or are unsure about wiring, consult a professional.

Garanti og support

Your Wallpad product is covered by the following:

  • Garanti: All products from our store come with a 1-year warranty.
  • Returnerer: You may return products within 7 days if there are any quality problems.
  • Kundesupport: For any inquiries or assistance, please contact customer service. All emails will be answered within 24 hours.
Warranty and Service information including 7-day returns, 1-year warranty, and 24-hour email support
Figur 8: Garanti og service udløberview.

Relaterede dokumenter - L3-BG-DIY

Preview Konfigurationer for lyskontaktledninger: 1-vejs, 2-vejs og mellemliggende
Detaljeret vejledning til forståelse og implementering af 1-vejs, 2-vejs og mellemliggende ledningskonfigurationer til lysafbrydere, inklusive tekstlige beskrivelser af diagrammer og komponenter.
Preview Sådan opgraderer du en lysdæmper sikkert: En gør-det-selv-guide
Trinvise instruktioner og sikkerhedsråd til opgradering af en lysdæmper derhjemme, der dækker værktøj, ledningsføring og regler. Inkluderer ændringer af ledningsfarver.
Preview BG-ledningstilbehør: Installationsvejledning til enkelt- til dobbeltkonverterstik
Detaljerede installationsvejledninger og sikkerhedsadvarsler til BG Electrical enkelt- til dobbeltkonverterstikkontakten, inklusive tekniske specifikationer og miljøbeskyttelsesoplysninger.
Preview BG Electrical 13A RCD-kontakt: Installations- og sikkerhedsvejledning
Omfattende vejledning til installation og sikker betjening af BG Electrical 13A RCD-stikkontakt, inklusive ledningsføringsinstruktioner, sikkerhedsråd og tekniske specifikationer.
Preview BG Electrical WP23TM24 Tidsstyret 13A Vejrbestandig Stikkontakt - Tekniske Data og Installationsvejledning
Omfattende tekniske specifikationer, funktioner, installationsvejledning og brugervejledning til BG Electrical WP23TM24, en 13A vejrbestandig timerstikkontakt med IP66-klassificering, egnet til udendørs brug.
Preview MRCOOL DIY-serien multizone kanalfri mini-split varmepumpe aircondition - 4. generation
Udforsk MRCOOL DIY-serien af ​​multi-zone kanalfri mini-split varmepumpe-klimaanlæg med nem installation, smart home-integration og fleksibel komfort for op til 5 zoner. Inkluderer detaljerede specifikationer og modelmatchninger.