TOOLTOP ET2010A

TOOLTOP ET2010A Oscilloscope Multimeter User Manual

Model: ET2010A | Brand: TOOLTOP

1. Introduktion

The TOOLTOP ET2010A is a versatile 2-in-1 device combining the functionalities of an oscilloscope and a digital multimeter. Designed for electrical professionals and DIY enthusiasts, it offers high-speed sampling, a wide analog bandwidth, and a clear color display for accurate and efficient measurements. This manual provides detailed instructions for the safe and effective use of your ET2010A device.

TOOLTOP ET2010A Oscilloscope Multimeter 2-in-1 device showing various measurement modes and its graphical display.
TOOLTOP ET2010A Oscilloscope Multimeter 2-in-1 device showing various measurement modes and its graphical display.

2. Nøglefunktioner

  • 2-i-1 funktionalitet: Combines oscilloscope and 4000-count digital multimeter.
  • Høj ydeevne: 2.5Msps højhastigheds-sampling rate and 1MHz analog bandwidth.
  • Waveform Capture: One-click visual wave with automatic, conventional, and single scanning modes.
  • Datalagring: Save up to 100 sets of data and 10 waveforms.
  • Customizable Waveform Parameters: Independently set time base, amplitude, and scanning mode.
  • REL Function: Effectively eliminates lead resistance, distributed capacitance, and interference signals for more accurate readings.
  • Comprehensive Multimeter Functions: Måler DC/AC voltage/current, resistance, capacitance, frequency, duty cycle, diode, and continuity.
  • Brugervenlig skærm: 2.4-inch color screen displays measurement data and historic data simultaneously.
  • Sikkerhed: Overload protection with 10A double protective tube.
  • Strømstyring: Automatic shutdown after 15 minutes of inactivity (can be disabled).
  • Pålidelighed: No potentiometer adjustment required for panel or internal storage calibration.
Summary of TOOLTOP ET2010A advantages: 2-in-1, adjustable time base/amplitude, 320*240 screen, safety features, auto waveform capture, 3 trigger modes, REL+MAX, 100 data sets, 10 waveforms.
Summary of TOOLTOP ET2010A advantages: 2-in-1, adjustable time base/amplitude, 320*240 screen, safety features, auto waveform capture, 3 trigger modes, REL+MAX, 100 data sets, 10 waveforms.

3. Opsætning

3.1 Batteriinstallation

  1. Sørg for, at enheden er slukket.
  2. Find batterirummet på bagsiden af ​​enheden.
  3. Åbn batterirummets dæksel.
  4. Isæt tre (3) AA-batterier, og sørg for at polerne vender korrekt (+/-). Bemærk: Batterier er ikke inkluderet.
  5. Luk batterirummets dæksel forsvarligt.

3.2 Indledende tænding

Turn the central rotary knob from the 'OFF' position to any measurement function (e.g., 'AUTO' for voltage) to power on the device.

3.3 Quiet Mode Activation

To enter mute mode, hold down the F4 key while turning the rotary knob to power on the machine.

TOOLTOP ET2010A showing quiet mode activation by holding F4 key while turning the knob, with a sound wave icon.
Quiet mode activation: Hold F4 key while turning the knob to power on.

4. Betjeningsvejledning

4.1 Oscilloskopets drift

The ET2010A features a graphical display for waveform analysis.

  1. Aktivering af oscilloskoptilstand: Turn the rotary knob to the 'OSC' position.
  2. One-Touch Automatic Waveform Capture: Press the 'AUTO' button (F1) to automatically capture and display the waveform.
  3. Adjusting Waveform Parameters: Use the F2 and F3 buttons to adjust the time base and amplitude of the displayed waveform.
  4. Triggertilstande: The device supports three waveform scanning modes:
    • Automatisk tilstand: Automatically acquires waveform data without a specific trigger signal.
    • Normal tilstand: Acquires waveform data when a trigger signal is detected.
    • Enkelt tilstand: Acquires a single waveform data when a trigger signal is detected.
  5. Gemmer bølgeformer: Press the 'SAVE' button (F4) to save the current waveform. The device can store up to 10 waveforms.
Demonstration of TOOLTOP ET2010A Oscilloscope Multimeter functions, including voltage measurement, oscilloscope operation with adjustable time base and amplitude, current waveform detection, AC/DC voltage detection, resistance, diode, capacitance measurements, and backlight adjustment.
TOOLTOP ET2010A demonstrating one-touch automatic waveform capture with four different waveform examples (square, ramp, sine, pulse).
One-touch automatic waveform capture function.
TOOLTOP ET2010A highlighting mass storage capacity: 100 sets of data and 10 waveform records, shown with multiple waveform displays.
Mass storage for 100 sets of data and 10 waveform records.

4.2 Multimeterbetjening

Turn the rotary knob to the desired measurement function. Connect the test leads appropriately to the COM and VΩCx or 10A jacks.

  • Voltage-måling (DC/AC): Select 'V' (DC or AC) on the rotary knob. The device supports auto-ranging.
  • Strømmåling (DC/AC): Select 'A' (DC or AC) on the rotary knob. Ensure proper connection for current measurement (10A jack).
  • Modstandsmåling: Select 'Ω' on the rotary knob.
  • Kapacitansmåling: Select 'Cx' on the rotary knob.
  • Frequency/Duty Cycle Measurement: Select 'Hz/%' on the rotary knob.
  • Diode test: Select the diode symbol on the rotary knob.
  • Kontinuitetstest: Select the continuity symbol (beep) on the rotary knob.
Examples of measurement displays on TOOLTOP ET2010A: Waveform, AC Voltage, Resistance, and Capacitance.
Examples of various measurement displays including waveform, AC voltage, modstand og kapacitans.

4.3 Specialfunktioner

  • REL (relativ måling): Press the 'REL' button to enter relative measurement mode. This function effectively eliminates lead resistance, distributed capacitance, and interference signals, providing more accurate readings.
  • MAX/MIN Test: Use the 'MAX/MIN' function to record the maximum and minimum values during a measurement process, aiding in data analysis.
  • Justering af baggrundsbelysning: The display features a bright backlight for clear visibility.
  • Auto-søvn: The device will automatically shut down after 15 minutes of no operation to conserve battery life. This feature can be disabled in settings.
TOOLTOP ET2010A showing REL and MAX/MIN functions for accurate testing and data analysis.
REL and MAX/MIN functions for enhanced measurement accuracy and data analysis.
TOOLTOP ET2010A highlighting the 15-minute auto-sleep function with a clock icon.
Automatisk slukning efter 15 minutters inaktivitet for at spare strøm.

5. Specifikationer

5.1 Generelle funktioner

FeatureSpecifikation
Vise240x320 Color screen
BaggrundsbelysningKonstant på
BatteriAA batteries*3 (Not included)
ArbejdsstrømCirka 65mA
BrugstidMere end 10 timer
Driftsbetingelser0°C - +40°C; <75%RH
Dimensioner77 mm x 157 mm x 25.5 mm
Observation Area49.0 mm x 36.7 mm
IndgangsmodstandOmkring 10MΩ
Automatisk nedlukning15 minutter eller deaktiveret
SovestrømOmkring 35uA
Lagerkapacitet100 data sets, 10 waveforms
Opbevaringsbetingelser-10°C ~ +60°C; <90%RH
VægtOmkring 135 g

5.2 Oscilloskopets egenskaber

KarakteristiskSpecifikation
Analog båndbredde1MHZ
Kanal1
Scan-tilstandAuto/Normal/Enkelt
Vertikalt følsomhedsområde300mV ~ 100V per grid
Lodret Amplitude Nøjagtighed± (5% + 0.2 div)
Automatisk konfigurationAuto set time base and vertical amplitude
Maks. realtids-Sampling Rate2.5 Msps
IndgangsmodstandOmkring 10MΩ
Tidsbaseområde2.5us ~ 10s per grid
Tidsbasenøjagtighed±(0.01 % + 0.1 div)
Valg af triggerkantRising/falling edge
Automatic Measurement FunctionVp-p, Vavg, Vrms, HZ

5.3 Multimeter Characteristics

MålingRækkevidde
DC bindtage400mV - 600V
DC-strøm4A ~ 10A
Modstand400.0Ω ~ 40.00MΩ
Frekvens5Hz ~ 5MHz
DiodetestVoltage er omkring 1.5 V
AC Voltage400mV ~ 600V
AC strøm4A ~ 10A
Kapacitans51.2nF ~ 100uF
Duty Cycle0 % ~ 100 %
KontinuitetstestResistance < 50Ω, with beep
Detailed product parameter table for TOOLTOP ET2010A, including bandwidth, sampling rate, display, battery, storage, fuse, size, weight, use/storage conditions, input resistance, DC/AC voltage/current, resistance, frequency, diode test, capacitance, duty cycle, continuity test.
Detailed product parameter table for TOOLTOP ET2010A.

6. Vedligeholdelse

6.1 Generel pleje

  • Hold enheden ren og tør. Tør af med en blød, tør klud.amp klud om nødvendigt. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Undgå at udsætte enheden for ekstreme temperaturer, fugt eller direkte sollys.
  • Store the device in a safe place when not in use, preferably in its carrying pouch, to prevent damage.
  • Hvis enheden ikke skal bruges i længere tid, skal batterierne fjernes for at forhindre lækage.

6.2 Udskiftning af sikringer

The device is equipped with a 10A/250V double protective tube for overload protection. If the fuse blows due to an overload, it must be replaced with a fuse of the same type and rating to ensure continued safety and functionality.

  1. Ensure the device is powered off and disconnect all test leads.
  2. Refer to the device's internal diagram (if available in the full manual) for the exact location of the fuse.
  3. Åbn forsigtigt c'enasing (if user-serviceable) or consult a qualified technician.
  4. Replace the blown fuse with a new 10A/250V fuse.
  5. Luk casing sikkert.
TOOLTOP ET2010A highlighting safety features: Auto Range and 10A/250V fuse double protection.
Safety features include a 10A/250V fuse for double protection.

7. Fejlfinding

  • Enheden tændes ikke: Kontroller batteriinstallationen, og sørg for, at batterierne ikke er afladede. Udskift om nødvendigt.
  • Unøjagtige aflæsninger: Ensure test leads are properly connected and not damaged. Use the REL function to eliminate interference. Verify the correct measurement mode is selected.
  • Ingen visning af bølgeform: Check the input signal. Ensure the oscilloscope is in the correct mode (Auto/Normal/Single) and trigger settings are appropriate.
  • Skærmen er svag eller ulæselig: Adjust the backlight. If batteries are low, replace them.

For persistent issues not covered here, please consult the full user manual or contact customer support.

8. Brugertips

  • Always start with the 'AUTO' range function for multimeter measurements to prevent overload, then switch to manual range if more precision is needed.
  • When using the oscilloscope, experiment with different time base and amplitude settings to get a clear view af bølgeformen.
  • Utilize the data and waveform saving features to document your measurements for later analysis or comparison.
  • The compact size and integrated kickstand make the ET2010A ideal for fieldwork and benchtop use.
TOOLTOP ET2010A being held in a pocket, illustrating its small volume, lightweight, and portable design.
The compact and portable design of the ET2010A.
Tilbage view of TOOLTOP ET2010A Oscilloscope Multimeter showing the integrated kickstand.
Integrated kickstand for convenient hands-free operation.

9. Garanti og support

For warranty information, technical support, or service inquiries, please refer to the official product documentation provided with your purchase or contact TOOLTOP customer service. Keep your proof of purchase for warranty claims.

10. Pakkens indhold

Upon opening your TOOLTOP ET2010A package, you should find the following items:

  • 1 x TOOLTOP ET2010A Oscilloscope Multimeter
  • 1 x par prøveledninger
  • 1 x engelsk brugervejledning
  • 1 x emballeringsboks
TOOLTOP ET2010A Oscilloscope Multimeter with test leads, carrying pouch, and user manual, illustrating package contents.
Contents included in the TOOLTOP ET2010A package.

Documents - TOOLTOP – ET2010A

ingen relevante dokumenter