VICTOR 834BW

VICTOR 834BW Intelligent Digital Lydniveaumåler Brugermanual

Model: 834BW

1. Introduktion

The VICTOR 834BW is an intelligent digital sound level meter designed for accurate and real-time monitoring of noise levels. Featuring a large 4-inch digital display, audible and visual alarms, and app connectivity, it is suitable for various environments such as factories, schools, libraries, offices, and transportation hubs. This manual provides detailed instructions for the proper use and maintenance of your device.

Front view of the VICTOR 834BW Sound Level Meter
Figur 1: Forside view of the VICTOR 834BW Sound Level Meter.

2. Pakkens indhold

Kontroller venligst pakkens indhold ved udpakning for at sikre, at alle varer er til stede:

  • VICTOR 834BW Sound Level Meter
  • Instruktionsmanual
  • Overensstemmelsescertifikat
  • Strømadapter (DC5V/2A)
  • USB Wiring Cable
  • Hanging Hooks (2 pcs)
  • Suspension Screws
Packaging contents including the meter, instructions, adapter, USB cable, hanging hooks, and screws.
Figure 2: VICTOR 834BW Package Contents.

3. Specifikationer

Key technical parameters of the VICTOR 834BW Sound Level Meter:

ParameterVærdi
Måleområde30dB ~ 130dB
Nøjagtighed± 1.5dB
Frekvensrespons31.5Hz ~ 8.5KHz
FrekvensvægtningA Rights
SvartidFAST (approx. 1 second)
Sensortype6mm capacitor microphone sensor
Opløsningskraft0.1dB (<100dB); 1dB (≥100dB)
AlarmmeddelelseVoice + Display
Opdateringshastighed2 gange i sekundet
StrømforsyningsmetodeDC5V/2A
Arbejdsmiljø0°C ~ 40°C; 10% ~ 80% RH
Opbevaringsmiljø-10°C ~ 60°C; 10% ~ 70% RH
Visningsmetode3 digit digital tube display
Skærmstørrelse4-inch single word
Produktstørrelse323mm * 173mm * 40mm
Produktets vægtCirka 1038g
Detailed technical parameter table for the sound level meter.
Figur 3: Tekniske parametre.

4. Opsætning

4.1 Strømtilslutning

Connect the provided DC5V/2A power adapter to the meter's power input port and plug it into a suitable power outlet. The device will automatically power on and begin real-time noise monitoring.

4.2 Monteringsmuligheder

The VICTOR 834BW offers multiple fixation methods to suit various usage scenarios:

  • Vægmonteret: Use the provided hanging hooks and screws to securely mount the meter on a wall. Ensure the wall can support the device's weight.
  • Stående: Utilize the integrated kickstand on the back of the device for desktop or shelf placement.
  • Hængende: The device can also be hung from a ceiling or other overhead structure using appropriate fixtures.
Bag view of the meter showing mounting holes and kickstand.
Figur 4: Bagside view with mounting features.
Example of the meter hanging in a library setting.
Figur 5: Vægmonteret installation f.eks.ample.
Examples of the meter in standing (bedroom) and hanging (corridor) positions.
Figure 6: Standing and hanging installation examples.

5. Betjening

5.1 Tænd/sluk

Lightly press the power button () on the top of the device to turn it on or off. The meter will automatically begin real-time noise monitoring once powered on.

5.2 Realtidsovervågning

The large 4-inch digital display shows the current sound level in decibels (dBA). The display refreshes approximately twice per second, providing continuous monitoring.

Close-up of the 4-inch digital display showing a large number.
Figure 7: Large Digital Display.

5.3 Voice Announcement Reminder

Tap the "SEL" button to toggle the voice announcement reminder on or off. When the indicator light is on, voice announcements are active. When the indicator light is off, voice announcements are disabled.

5.4 Alarm Settings (Audible and Visual)

The device features both audible and visual alarms. To set the alarm value:

  1. Long press the "SEL" button to enter the alarm setting mode.
  2. Brug (ned) og (up) arrow keys to adjust the desired alarm threshold.
  3. Once the noise level reaches the set alarm value, a voice announcement will be made, and the display will provide a visual alert.
Display showing '54.4' with a magnifying glass icon, indicating audible and visual alarm.
Figure 8: Audible and Visual Alarm Function.

Watch this video for a demonstration of the device's functions, including power, voice announcement, and alarm settings:

Video 1: Function Demo - Power, Voice, and Alarm Settings.

6. App Connectivity (Bluetooth/WiFi)

The VICTOR 834BW supports Bluetooth and WiFi connectivity, allowing for real-time observation of ambient decibel levels via a mobile application. Refer to the specific app instructions for pairing and usage. This feature enables remote monitoring and data logging.

Icons representing real-time monitoring functions including Bluetooth WiFi.
Figure 9: Real-time Monitoring Functions including Bluetooth/WiFi.

The function demo video also illustrates the app connectivity process:

Video 2: Function Demo - App Connectivity.

7. Vedligeholdelse

To ensure the longevity and accuracy of your VICTOR 834BW Sound Level Meter, follow these maintenance guidelines:

  • Rensning: Brug en blød, tør klud til at rengøre enheden. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Opbevaring: Store the meter in a dry place within the specified storage environment (-10°C ~ 60°C; 10% ~ 70% RH) when not in use.
  • Ventilation: The device features a multi-vent induction design for instrument ventilation. Ensure these vents are not obstructed to maintain optimal performance.
Back design with multi-vent induction for instrument ventilation.
Figure 10: Multi-vent induction design for proper ventilation.

8. Fejlfinding

If you encounter issues with your VICTOR 834BW, please refer to the following common troubleshooting steps:

  • Ingen skærm/enhed tænder ikke:
    • Ensure the power adapter is securely connected and plugged into a working power outlet.
    • Verify the power button has been pressed lightly.
  • Alarm aktiveres ikke:
    • Check if the voice announcement reminder is enabled (indicator light on).
    • Verify that the alarm threshold is set correctly and the ambient noise level exceeds it.
  • Upræcise læsninger:
    • Ensure the microphone sensor is clean and unobstructed.
    • Operate the device within the specified work environment temperature and humidity ranges.
    • Avoid placing the meter near strong electromagnetic fields or vibrations.
  • Problemer med appforbindelse:
    • Ensure Bluetooth/WiFi is enabled on your mobile device.
    • Make sure the meter is within range of your mobile device or WiFi network.
    • Restart both the meter and your mobile device.

9. Brugertips

Maximize your experience with the VICTOR 834BW Sound Level Meter with these helpful tips:

  • Optimal placering: For the most accurate readings, place the meter away from direct sound sources, reflective surfaces, and air vents.
  • Regelmæssig overvågning: Utilize the app connectivity for continuous monitoring and data logging, which can help identify noise trends over time.
  • Alarmtilpasning: Adjust the alarm threshold to suit the specific requirements of your environment, whether it's a quiet library or a busy factory floor.
  • Miljøbevisthed: Use the meter to raise awareness about noise pollution and encourage quieter environments in shared spaces.

10. Garanti og support

The VICTOR 834BW Intelligent Digital Sound Level Meter comes with a 1-year warranty from the date of shipment. For technical support, warranty claims, or any other inquiries, please contact the manufacturer:

Fabrikant: Xi'an Beicheng Electronics Co., Ltd.
Adresse: Tilføj: JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORD DISTRIKT, XI'AN
E-mail: monkey6501@china-victor.com
Telefon: +86-13924679853 (Wechat/WhatsApp)
Various product certifications including CE, RoHS, UKCA, ISO, FC, and IAF.
Figur 11: Produktcertificeringer.

VICTOR 834BW Bluetooth Wi-Fi digital lydniveaumåler med app-styring og alarm

VICTOR 834BW Bluetooth Wi-Fi digital lydniveaumåler med app-styring og alarm

0:45 • 1280×720 • demonstration
VICTOR 834BW Bluetooth Wi-Fi støjmåler: Digital lydniveaumåler med app-styring og alarm

VICTOR 834BW Bluetooth Wi-Fi støjmåler: Digital lydniveaumåler med app-styring og alarm

0:45 • 1280×720 • feature_demo

Relaterede dokumenter - 834 BW

Preview VICTOR 4105A Digital Jordmodstandsmåler Brugsanvisning
Omfattende brugsanvisning til VICTOR 4105A digital jordtester, der dækker overview, sikkerhedsforanstaltninger, arbejdsprincip, tekniske specifikationer, målemetoder, batteriinstallation og fejlfinding.
Preview Victor 6013B Smart SMD Komponenttester Brugsanvisning
Detaljeret instruktionsmanual til Victor 6013B Smart SMD-komponenttesteren, der dækker introduktion, sikkerhedsregler, betjening af knapper, tekniske specifikationer, testprocedurer for modstande, kondensatorer og dioder samt vedligeholdelsesretningslinjer.
Preview Brugermanual til VICTOR 1010-seriens digitale lysmåler
Omfattende brugermanual til VICTOR 1010-seriens digitale lysmåler, der beskriver dens funktioner, betjening, sikkerhedsretningslinjer, display og udseende, nøglefunktioner, Bluetooth-forbindelse og tekniske specifikationer. Indeholder instruktioner til brug, fejlfinding og vedligeholdelse.
Preview VICTOR 468 netværkskabel tester instruktionsmanual
Brugsanvisning til VICTOR 468 netværkskabeltester, der beskriver dens funktioner, testprocedurer for dobbeltsnoede kabler, indikatorer for unormale forbindelser og vigtige advarsler.
Preview Brugermanual til Victor Personal Massager og Joyhub-appguide
Omfattende brugermanual til Victor-massageapparatet med detaljerede oplysninger om produktets funktioner, app-forbindelse med Joyhub, brugsanvisninger, pleje, advarsler og garantioplysninger. Understøtter flere sprog.
Preview Victor 8145C digitalt multimeter med dobbelt display brugermanual og specifikationer
Omfattende brugermanual til Victor 8145C digitalt multimeter med dobbelt display, der dækker funktioner, betjening, sikkerhed, specifikationer og vedligeholdelse. Indeholder detaljerede instruktioner og tekniske data.