Acrel ACR320EL

Acrel ACR320EL multifunktionsmåler brugermanual

Model: ACR320EL Series

Mærke: Acrel

1. Introduktion

The Acrel ACR320EL is a high-precision multi-function power meter designed for comprehensive electrical parameter measurement and centralized remote monitoring. It supports three-phase current and voltage measurement, energy statistics, and features RS485 communication for integration into larger systems. This manual provides essential information for the safe installation, operation, and maintenance of your ACR320EL meter.

2. Sikkerhedsoplysninger

Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

  • Installation og vedligeholdelse bør kun udføres af kvalificeret personale.
  • Ensure power is disconnected before performing any wiring or installation procedures.
  • Verify correct wiring according to the provided diagrams to prevent damage to the meter or connected equipment.
  • Do not operate the meter in environments exceeding its specified operating conditions (temperature, humidity).
  • Protect the device from moisture, dust, and corrosive substances.
  • Release any static electricity before handling the device.

3. Produktet er slutview

3.1 Funktioner

  • Three-phase current measurement
  • Voltage måling
  • LED/LCD display with backlight
  • RS485 kommunikationsgrænseflade
  • Maximum demand record
  • Time-of-use energy statistics
  • 12-month energy statistics
  • Hændelsesrekord
List of features for Acrel multi-function meter
Figure 3.1: Key Features of the Acrel Meter

3.2 Komponenter

The meter consists of a front panel with an LCD display and control buttons, and a rear panel with various terminals for power input, current/voltage inputs, pulse output, analog output, and RS485 communication.

Front view of the Acrel ACR320EL multi-function meter
Figur 3.2: Forside View of ACR320EL
Bag view of the Acrel ACR320EL multi-function meter showing terminal connections
Figur 3.3: Bagside View with Terminal Layout

4. Specifikationer

AttributVærdi
DIY forsyningerElektrisk
OprindelseFastlandet Kina
Meget bekymret kemikalieIngen
Current Transformer (CT) Accuracy0.5s class (compatible with 1.5A and 6A CTs)

4.1 Dimensioner

The ACR series meters come in various sizes. Please refer to the specific model for exact dimensions.

  • ACR120 Series: 84 mm (B) x 84 mm (H) x 92 mm (D)
  • ACR220 Series: 96 mm (B) x 96 mm (H) x 95 mm (D)
  • ACR320 Series: 120 mm (B) x 120 mm (H) x 92 mm (D)
Dimensional drawings for ACR120, ACR220, and ACR320 series meters
Figure 4.1: ACR Series Product Dimensions

5. Opsætning og installation

Follow these steps for proper installation of the meter into a panel:

  1. If the panel does not have a pre-cut opening, create a suitable hole according to the meter's dimensions.
  2. Before handling, discharge any static electricity. Remove the installation terminals from the meter.
  3. Insert the meter into the panel opening.
  4. Use the two provided mounting brackets to secure the device firmly to the installation panel. The brackets have a locking function to ensure a stable fit.
Four-step diagram illustrating the panel mounting process for the Acrel meter
Figur 5.1: Installationsdiagram

6. Ledningsdiagram

Proper wiring is critical for the safe and accurate operation of the meter. Refer to the diagrams below for common wiring configurations. Always ensure power is off before making any connections.

6.1 Lav Voltage Three-Phase Four-Wire Connection

Wiring diagram for a low voltage three-phase four-wire system with the Acrel meter
Figur 6.1: Lav Voltage Three-Phase Four-Wire Wiring

6.2 Høj Voltage Three-Phase Three-Wire Connection

For høj voltage three-phase three-wire connections, consult the detailed wiring instructions provided with your specific model or contact technical support for guidance. The meter supports configuration for different wiring modes.

7. Betjening

The ACR320EL meter features an LCD display and four control buttons for navigation and configuration.

Front panel of the Acrel meter showing LCD display and control buttons
Figure 7.1: Front Panel and Button Functions

7.1 Knapfunktioner

  • SET -knap: Press this button to enter the programming mode for configuration.
  • Venstre pileknap: Bruges til at navigere i menuer eller dekretereasing-værdier.
  • Højre pileknap: Bruges til at navigere i menuer eller øgeasing-værdier.
  • Enter Button (Return/Confirm): Used to confirm selections or exit menus.

7.2 Skærmnavigation

The LCD display shows various electrical parameters. Use the arrow buttons to scroll through different measurement screens (e.g., voltage, current, power, energy). The SET button allows access to configuration menus where parameters like CT ratio, wiring mode, and time-of-use settings can be adjusted.

8. Vedligeholdelse

To ensure the longevity and accurate performance of your Acrel ACR320EL meter, follow these maintenance guidelines:

  • Rensning: Regularly clean the meter's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Miljøforhold: Ensure the operating environment remains within specified temperature and humidity ranges. Avoid exposure to direct sunlight, excessive heat, or extreme cold.
  • Tilslutningstjek: Periodically inspect all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to inaccurate readings or device malfunction.
  • Firmwareopdateringer: Tjek producentens website for any available firmware updates that may improve performance or add new features. Follow update instructions carefully.
  • Kalibrering: If you suspect inaccurate readings, professional calibration may be required. Contact Acrel technical support for assistance.

9. Fejlfinding (FAQ)

Dette afsnit omhandler almindelige spørgsmål og problemer, du måtte støde på.

Q: Can the time-of-use tariff periods and regions be changed on-site if they were incorrectly set at purchase?
A: Yes, these settings can be modified on-site through the meter's programming interface.
Q: The meter was configured for a 5A current transformer (CT) input, but the on-site CT ratio is 1A. Can the meter be adjusted for this?
A: The meter's accuracy is 0.5s class, and it is generally compatible with current transformers of 1.5A (6A) ratings. The meter's settings can typically be adjusted to match various CT ratios within its operational range. Consult the programming manual for specific CT ratio configuration steps.
Q: The meter was supplied for a three-phase four-wire system, but the on-site installation is three-phase three-wire. Can the meter be reconfigured?
A: Yes, the meter allows for switching between different wiring modes (e.g., three-phase three-wire, three-phase four-wire) through its internal settings in programming mode.
Frequently Asked Questions regarding Acrel energy meters
Figur 9.1: Almindelige spørgsmål om fejlfinding

10. Brugertips

  • Konfigurationsfleksibilitet: The meter offers significant flexibility in adjusting parameters like time-of-use tariffs, current transformer ratios, and wiring modes. Take advantage of these settings to precisely match your installation requirements.
  • Dokumentation: Keep this manual and any supplementary programming guides handy for quick reference during setup and operation.
  • Systemintegration: For advanced applications, familiarize yourself with the RS485 communication protocol to effectively integrate the meter into your centralized remote monitoring system.

11. Garanti og support

For warranty information, technical support, or service inquiries, please refer to the official Acrel website or contact your authorized dealer. Ensure you have your product model and serial number available when seeking support.

Relaterede dokumenter - ACR320EL

Preview Acrel ACR10R Skinnetype Multifunktions elektrisk Instrument med Ekstern Split Core Strømtransformer - Brugs- og Installationsmanual
Denne manual indeholder omfattende instruktioner til Acrel ACR10R-serien af ​​skinnelignende multifunktions elektrisk instrument, herunder specifikationer, funktioner, installation, programmering og RS485 MODBUS-RTU-kommunikation. Den beskriver tekniske parametre, tilslutningstilstande, driftsprocedurer og fejlfindingsvejledning til industrielle og kommercielle strømovervågningsapplikationer.
Preview ADL100-ET enfaset elmåler installations- og driftsvejledning
Omfattende installations- og betjeningsvejledning til Acrel ADL100-ET enfaset elmåler. Denne manual indeholder tekniske specifikationer, funktionsbeskrivelser, ledningsføringsinstruktioner, displaymenuer, programmeringsprocedurer og kommunikationsprotokoller (Modbus RTU).
Preview Acrel ADL3000-E Smart Meter: Installations- og betjeningsmanual
Omfattende installations- og betjeningsvejledning til Acrel ADL3000-E smartmåleren, der dækker tekniske specifikationer, ledningsføring, displayfunktioner og kommunikationsprotokoller.
Preview Acrel ATE-seriens trådløse temperatursensor installationsvejledning V1.9
Dette dokument indeholder installationsvejledning til Acrel ATE-seriens trådløse temperatursensorer, der dækker produkt overview, typeintroduktion, tekniske funktioner, installationsmetoder for forskellige modeller (ATE100M, ATE100, ATE200, ATE400) og trådløse temperaturkoordinatorer (ATC450-C, ATC600). Den beskriver specifikationerne, installationsprocedurerne og vigtige forholdsregler for brug af disse sensorer i elektrisk koblingsudstyr.
Preview ATE 系列无线测温传感器安装说明 V1.7
Læs mere om ATE系列无线测温传感器的产品概述、型号说明、技术指标、安装方法什乏ﺌ 3-35kV 户内开关柜和 0.4kV 低压柜.