CEM DT-859B

CEM DT-859B 5-in-1 Multifunction Environment Meter

Brugervejledning

1. Introduktion

The CEM DT-859B is a versatile 5-in-1 multifunction environment meter designed for professional and home use. It integrates the functions of a Sound Level Meter, Light Meter, Humidity Meter, Temperature Meter, and CFM/CMM Thermo-Anemometer into a single, portable device. This instrument is ideal for a wide range of applications including noise measurement in various environments, luminance assessment, environmental analysis, fume hood testing, and HVAC system assessment.

2. Produktet er slutview

The DT-859B combines five key environmental measurement capabilities:

  • Sound Level Meter: For measuring noise levels in factories, schools, offices, and homes, and for checking acoustics.
  • Lysmåler: For measuring luminance, fully cosine corrected for angular incidence of light. Utilizes a stable, long-life silicon diode.
  • Humidity/Temperature Meter: Uses a humidity/semiconductor sensor and K-type thermocouple for accurate readings.
  • CFM/CMM Thermo-Anemometer: Measures air velocity and flow, suitable for plant maintenance, environmental analysis, and HVAC systems.
CEM DT-859B main unit with all five probes connected

Figure 2.1: CEM DT-859B Main Unit with All Probes Connected

Close-up of DT-859B display and control buttons

Figure 2.2: Close-up of DT-859B Display and Control Buttons

Pakkeindhold:

Contents of the CEM DT-859B package

Figur 2.3: Pakkens indhold

Pakken indeholder typisk:

  • DT-859B Main Unit
  • Sound Level Probe
  • Lysprobe
  • Humidity/Temperature Probe
  • Anemometer Vane Probe
  • K-Type termoelement
  • Bæretaske
  • Brugermanual
  • Software CD (for data logging, if applicable)

3. Specifikationer

FungereRækkeviddeOpløsningNøjagtighed
Type K Temp-200°C til 1372°C (-328°F til 2501°F)0.1°Above -100°C (-148°F): ±[0.15%rgd+1°C(1.8°F)]
Below -100°C (-148°F): ±[0.5%rgd+2°C(3.6°F)]
Lufttemp-30°C~100°C (-22°F~199°F)0.1°± 1 ° C / 1.8 ° F
Fugtighed0~100% RH0.1% RH± 3.5% RH
Lydniveau30dB~130dB0.1dB±3.5dB
Lys20, 200, 2000, 20000Lux0.01, 0.1, 1, 10Lux±5% ±10d
Anemo (m/s)0.40-30.00 m/s0.01 m/s±3 % ±0.20 m/s
Anemo (ft/min)80-5900 fod/min1 fod/min±3 % ±40 fod/min
Anemo (km/h)1.4-108.0 km/t0.1 km/t±3 % ±0.8 km/t
Anemo (MPH)0.9-67.0 MPH0.1 MPH±3% ±0.4 MPH
Anemo (Knots)0.8-58.0 Knots0.1 knob±3 % ±0.4 knob
Luftstrøm (CFM)0-999,900 CFM0.001 til 100 CFMAccuracy is function of velocity and area
Luftstrøm (CMM)0-999,900 CMM0.001 til 100 CMMAccuracy is function of velocity and area

4. Opsætning

4.1 Batteriinstallation

The DT-859B requires a 9V battery (or specified equivalent). To install or replace the battery:

  1. Find batteridækslet på bagsiden af ​​enheden.
  2. Åbn dækslet ved at skubbe eller skrue det af.
  3. Isæt 9V-batteriet, og overhold den korrekte polaritet (+/-).
  4. Luk batterirummets dæksel forsvarligt.

4.2 Tilslutning af sonder

The DT-859B uses various external probes for its multifunctionality. Connect the desired probe to the corresponding port on the main unit. Ensure connections are firm to prevent inaccurate readings.

  • Sound Level Probe: Connect the microphone probe to the designated audio input jack.
  • Light Probe: Plug the light sensor probe into its dedicated port.
  • Humidity/Temperature Probe: Connect the combined humidity and temperature sensor.
  • Anemometer Vane Probe: Connect the anemometer vane to its input port.
  • K-Type Thermocouple: For external temperature measurements, connect the K-type thermocouple to the appropriate input terminals.
Hand holding DT-859B with humidity/temperature probe and K-type thermocouple connected

Figure 4.1: Connecting the Humidity/Temperature Probe and K-Type Thermocouple

Hands holding DT-859B and anemometer vane probe, showing connection

Figure 4.2: Connecting the Anemometer Vane Probe

5. Betjeningsvejledning

5.1 Tænd/sluk

Tryk på Magt button (usually a yellow button with a power symbol) to turn the device on. Press and hold the same button to turn it off.

5.2 Funktionsvalg

Brug MODE button to cycle through the different measurement functions: Sound, Light, Humidity/Temperature, and Anemometer. The selected function will be indicated on the display.

5.3 Udførelse af målinger

Once a function is selected, position the corresponding probe in the environment to be measured. Readings will be displayed on the LCD screen.

  • Lydniveau: Point the microphone towards the sound source.
  • Lys: Position the light sensor to face the light source.
  • Humidity/Temperature: Place the probe in the area where humidity and temperature are to be measured. For K-type temperature, ensure the thermocouple tip is in contact with the object.
  • Vindmåler: Hold the vane probe in the airflow, ensuring the airflow passes through the vane freely.

5.4 Dataholdefunktion

Tryk på HOLDE button to freeze the current reading on the display. Press it again to release and resume live measurements.

5.5 MAX/MIN/AVG Readings

Tryk på MAKS/MIN/GNS button to cycle through the maximum, minimum, and average readings recorded since the function was selected or reset. Press and hold to reset the recorded values.

5.6 Valg af enhed

Brug ENHED or OPSÆTNING button (refer to the specific button labels on your device, often combined with arrow keys) to change measurement units (e.g., °C/°F for temperature, m/s/ft/min/km/h/MPH/Knots for anemometer, CFM/CMM for air flow).

5.7 Baggrundslys

The device features a backlight for visibility in low-light conditions. Press the Lyspære button to activate or deactivate the backlight.

6. Vedligeholdelse

6.1 Rengøring

  • Wipe the meter and probes with a dry, soft cloth.
  • Brug ikke slibemidler eller opløsningsmidler.
  • Keep the light sensor, microphone, and anemometer vane free from dust and debris.

6.2 Udskiftning af batteri

Replace the battery when the low battery indicator appears on the display to ensure accurate readings and proper operation. Follow the instructions in Section 4.1.

6.3 Opbevaring

When not in use for extended periods, remove the battery and store the meter and its probes in the provided carrying case in a cool, dry environment, away from direct sunlight and extreme temperatures.

6.4 Sensorpleje

  • Sound Level Microphone: Avoid dropping or exposing the microphone to moisture.
  • Lyssensor: Keep the dome clean and free from scratches.
  • Humidity/Temperature Probe: Protect the sensor from physical impact and corrosive substances.
  • Anemometer Vane: Ensure the vane rotates freely. Avoid touching the blades and protect them from damage.

7. Fejlfinding

ProblemMulig årsagLøsning
Måleren tænder ikkeDødt eller forkert installeret batteriCheck battery polarity; replace with a new 9V battery.
Unøjagtige aflæsningerDirty or damaged sensor; incorrect unit selected; environmental interferenceClean sensors; verify unit settings; ensure proper probe placement; avoid strong electromagnetic fields.
Probe not detected / No reading for a specific functionLoose or faulty probe connection; damaged probeEnsure probe is securely connected; try reconnecting; inspect probe for visible damage.
Display shows "OL" or "--- "Measurement range exceeded; sensor errorEnsure measurement is within the device's specified range; check sensor connection.

8. Garanti og support

The CEM DT-859B is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, technical support, or service inquiries, please refer to the documentation included with your product or contact the seller/manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents - CEM – DT-859B
[Pdf] Brugermanual Instruktioner
ÿþ C 2 4 A B supereyes ru L 7 0 5 O @ 3 8 E M D T Manual CEM DT 859B img instructions |||
DT-859 . DT-859 1- 5 1 3 2- 3 3- 4 3-1. 4 3-2. 4 4- 5 5- 6 6- 7 6-1- 7 6-2- 7 6-3- 7 6-4- 7 6-5- 8 6-6- 8 6-7- 8 6-8- 9 6-9- 9 6-10- 9 6-11- 10 6-12- 10 6-13- 10 6-14- 11 6-15- 1...
pointtal: 35 filestørrelse: 523.79 K sideantal: 14 dokumentdato: 2025-02-22
[Pdf] Garanti
Suzie CEM DT 859B 5 in 1 Digital Multifunctional Environment Meter 70mm Vane Introduction Feature The digital Multifunction has been Pg 3 of 4 GMM Technoworld Pte Ltd 8 Burn Road 05 01 Trivex Singapore 369977 Tel 65 6386 1815 Email sales@testmeter sg CEMDT859B testmeter webshaper pcm files |||
Introduction: CEM DT-859B 5-in 1 Digital Multifunctional Environment Meter 70mm Vane Sound, Light, Air Flow, Humidity, and Temperature The digital Multifunction Environment Meter has been designed to combine the functions of Sound Level Meter, Light Meter, Humidity Meter Temperature Meter and ...
pointtal: 25 filestørrelse: 478.78 K sideantal: 4 dokumentdato: 2021-06-09
[Pdf] Brugermanual Specifikationer
DT 859B v171213 cuiziyao The Specification of 5 In 1 Multifunction Environment Meter Jan 17 2023 — SETUP OFFSET 9 Page 10 User Manual 6 8 Velocity Unit When one want to change the velocity 16 pages CEM manual cosmel ar descargas SPR 102 ManualJan pagesSPARTNA in Digital MeterCEM manualspr mcosmel manualcdn shopify s files 0560 5988 7813 spr m v 1758191442 |||
...
pointtal: 19 filestørrelse: 5.83 millioner sideantal: 16 dokumentdato: 2017-12-13