PYROSOLAR GGH-3.5KW/GGH-6.5KVA

PYROSOLAR Hybrid Solar Inverter User Manual

Models: GGH-3.5KW (24V) / GGH-6.5KVA (48V)

1. Introduktion

This manual provides essential information for the safe and efficient operation of your PYROSOLAR Hybrid Solar Inverter. This advanced inverter is designed to provide reliable pure sine wave power for various applications, integrating an MPPT solar charge controller. It supports both off-grid and on-grid configurations and can operate with or without a battery.

2. Nøglefunktioner

  • Ren sinusbølgeudgang til følsom elektronik.
  • Capable of running without a battery (requires PV input above 150V).
  • Integrated MPPT solar charge controller for optimized solar energy harvesting.
  • Konfigurerbar input voltage-sortiment til husholdningsapparater og personlige computere via LCD-indstillinger.
  • Adjustable battery charging current based on application needs via LCD settings.
  • Konfigurerbar AC/Solcelleopladerprioritet via LCD-indstillinger.
  • Kompatibel med netspænding voltage eller generatorstrøm.
  • Automatisk genstart ved genoprettelse af klimaanlægget.
  • Comprehensive protection: Overload, Over temperature, Short circuit, Over Voltage, under bindtage, Backfill Protection.
  • Smart battery charger design for extended battery life.
  • Koldstartsfunktion.
Diagram illustrating comprehensive 360 degree protection features including over voltage, over temperature, short circuit, overload, over current, under voltage, and backfill protection.

Figure 2.1: Comprehensive 360° Protection Features

3. Opsætning og installation

Proper installation is crucial for the safety and performance of your inverter. It is recommended that installation be performed by a qualified professional.

3.1. Fysisk installation

Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure adequate clearance around the unit for proper airflow. The inverter should be securely fastened to a vertical surface.

Bag view of the Hybrid Solar Inverter showing various connection ports for AC input, AC output, battery, and solar panels.

Figur 3.1: Tilslutninger på inverterens bagpanel

3.2. Ledningsforbindelser

Refer to the diagrams below for typical wiring configurations. Ensure all connections are tight and correctly polarized. Use appropriate gauge wiring for all connections to prevent overheating and ensure optimal performance.

  1. Batteriforbindelse: Connect the battery bank to the designated battery terminals on the inverter. Ensure correct polarity (positive to positive, negative to negative). The GGH-3.5KW model requires a 24V battery bank, and the GGH-6.5KVA model requires a 48V battery bank.
  2. Tilslutning af solpanel (PV): Connect your solar array to the PV input terminals. Observe the maximum PV open circuit voltage (500VDC) and MPPT operating voltage rækkevidde (120-450V).
  3. AC-indgangsforbindelse: Connect the utility grid or generator AC input to the AC input terminals.
  4. AC-udgangstilslutning: Connect your loads to the AC output terminals.
  5. Kommunikationsgrænseflade: Utilize the RS232/RS485/CAN/Dry contact ports for monitoring and advanced control.
Diagrams illustrating five customized solutions for solar inverter applications, including integrated single-phase inverter system design, no generator application design, and with generator application design.

Figure 3.2: Customized Application Designs

Note: This is a wide voltage Hybrid Solar inverter. If operating without an external battery, the voltage from the solar panel must be above 150VDC for the inverter to function normally. If an external battery is connected, 120VDC PV input is sufficient for operation.

4. Betjeningsvejledning

4.1. Første opstart

After all connections are secure, switch on the battery breaker (if applicable), then the PV array breaker, and finally the AC input breaker. The inverter will perform a self-test and the LCD display will illuminate.

4.2. LCD-skærm og indstillinger

The inverter features an LCD display and control buttons for monitoring status and configuring operational parameters. You can configure:

  • Input voltage-serie (til husholdningsapparater eller personlige computere).
  • Batteriets opladningsstrøm.
  • Prioritet for AC/Solcelleoplader.

4.3. Opladningstilstande

Inverteren understøtter fire forskellige opladningstilstande for at optimere energistyringen:

  1. Solopladning: Prioriterer opladning fra solpaneler.
  2. Solprioritet: Uses solar power first, then utility power if solar is insufficient.
  3. Prioritet for elforsyning: Prioriterer opladning fra forsyningsnettet.
  4. Hybridopladning: Combines solar and utility charging based on settings.

4.4. Indlæsnings- og udgangsfunktioner

The inverter offers three load output working modes:

  1. PV-prioritet: Loads are powered primarily by solar energy.
  2. Prioritet af forsyningsvirksomheder: Loads are powered primarily by the utility grid.
  3. Inverter tilstand: Loads are powered by the inverter, typically from battery or solar.
Diagram showing four charging modes (Solar Charging, Solar Priority, Electricity Utility Priority, Hybrid Charging) and three load output working modes (PV Priority, Utility Priority, Inverter Mode).

Figure 4.1: Charging and Load Output Working Modes

5. Vedligeholdelse

To ensure the longevity and optimal performance of your inverter, regular maintenance is recommended:

  • Rensning: Rengør jævnligt inverterens yderside med en tør klud. Sørg for, at ventilationsåbningerne er fri for støv og snavs. Brug ikke flydende rengøringsmidler.
  • Forbindelseskontrol: Kontrollér årligt alle ledningsforbindelser for tæthed og tegn på korrosion. Efterspænd om nødvendigt.
  • Miljøtjek: Sørg for, at installationsmiljøet forbliver inden for de angivne driftstemperatur- og luftfugtighedsområder.
  • Batteriinspektion: If using external batteries, follow the battery manufacturer's maintenance guidelines.

6. Fejlfinding (FAQ)

Dette afsnit omhandler almindelige spørgsmål og problemer, du måtte støde på.

Q: Hvad er den nominelle udgangseffekt?
A: The GGH-3.5KW model has a rated output power of 3500W. The GGH-6.5KVA model has a rated output power of 5500W.
Q: Hvad er den maksimale ladestrøm for batteriet?
A: The maximum solar charging current is 80A. The maximum AC charging current is 60A.
Q: Hvad er den maksimale DC PV-indgang?
A: Det maksimale PV-volumen i åbent kredsløbtage er 500VDC.
Q: How many volts of external battery should I use?
A: Use a 24V battery bank for the GGH-3.5KW model and a 48V battery bank for the GGH-6.5KVA model.
Q: Will it work without batteries?
A: Yes, it can operate without batteries. However, the solar panel voltage must be above 150VDC for normal operation in this configuration.
Q: Hvilke BMS-protokoller understøttes?
A: PYLON or PACE protocols are supported.
Q: Can it support parallel or series connection?
A: No, this model does not support parallel or series connection.

7. Specifikationer

Detailed technical specifications for the PYROSOLAR Hybrid Solar Inverter.

Detailed specification table for GGH-6.5KVA and GGH-6.5KVA-Parallel models, including rated power, input/output AC voltage, surge power, peak efficiency, switching time, wave form, battery voltage range, charging curve, lithium battery charging strategy, maximum photovoltaic power, maximum PV open circuit voltage, MPPT range, maximum solar charging current, maximum AC charging current, solar charger type, product size, package size, net weight, communication interface, relative humidity, operating temperature, and storage temperature.

Figur 7.1: Detaljerede produktspecifikationer

PYROSOLAR Hybrid Solar Inverter Specifications
AttributGGH-3.5KW (24V)GGH-6.5KVA (48V)
ModelnummerGGH-3.5KW / GGH-6.5KVA
Nominel effekt3500W5500W
UdgangstypeENKELT
Størrelse (mm)490*302*110
Vægt (kg)8.449.7
Mærkenavnpyrosolar
Udgangsfrekvens50/60HZ
Er en smart enhedJa
OprindelseFastlandet Kina
CertificeringCE
BølgeformRen Sine Wave
Batteri voltage24V48V
Maksimal solcelleeffekt3500W5500W
Maksimal PV åbent kredsløb voltage500VDC
MPPT-område og arbejdsvolumentage120-450V
Maksimal solar ladestrøm80A
Maksimal AC ladestrøm60A
Solar oplader typeMPPT
Pakke størrelse (mm)346*536*178
KommunikationsgrænsefladeRS232/RS485CAN/Tørkontakt
Relativ luftfugtighed5 % til 95 % (Ikke-kondenserende)
Driftstemperatur-10°C til 50°C
Opbevaringstemperatur-15°C til 60°C

8. Brugertips

  • Batteriløs drift: If you plan to operate the inverter without an external battery, ensure your solar array can consistently provide more than 150VDC to initiate and maintain operation.
  • Voltage Matching: Always match the inverter's voltage (24V or 48V) with your battery bank's voltage.
  • Overvågning: Utilize the communication interfaces (RS232/RS485/CAN) to monitor system performance and adjust settings for optimal efficiency.

9. Garanti og support

9.1. Garantioplysninger

Dette produkt leveres med 1 års garanti fra købsdatoen. Garantien dækker fabrikationsfejl og funktionsfejl ved normal brug. Gem venligst din købsbevis til brug ved garantikrav.

9.2. Teknisk support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact the PYROSOLAR Factory Store directly. Contact information can typically be found on your purchase receipt or the seller's online store page.

© 2023 PYROSOLAR. All rights reserved.

Documents - PYROSOLAR – GGH-3.5KW/GGH-6.5KVA