1. Introduktion
The alloet 200EP Wire Tester Kit is a high-accuracy cable toner detector and finder designed for efficient cable and wire repair and testing. This versatile tool features an inductive amplifier and a tone generator, making it ideal for circuit tracing, short circuit testing, and identifying various line conditions such as noise or ringing. Its durable, wear-resistant, and corrosion-resistant construction ensures long-term reliability in professional and DIY applications.
2. Sikkerhedsoplysninger
- Always ensure the device is turned off when not in use or when changing batteries.
- Do not attempt to test live circuits with high voltage. This device is intended for low-voltage communication and network cables.
- Use the insulated probe to prevent accidental short circuits and ensure user safety.
- Hold enheden væk fra vand og ekstreme temperaturer.
- Åbn ikke enheden casing beyond the battery compartment, as there are no user-serviceable parts inside.
3. Pakkens indhold
Tjek venligst pakken for følgende varer:
- 1 x Cable Tester (Inductive Amplifier Probe and Wire Tracker Tone Generator)
- 1 x Opbevaringspose
- 1 x Brugermanual (dette dokument)
- 1 x Replacement Head (for the probe)
4. Produktet er slutview
The alloet 200EP Wire Tester Kit consists of two main components: the Inductive Amplifier Probe and the Wire Tracker Tone Generator.

Figure 4.1: alloet 200EP Cable Tester Tone Generator components.
4.1. Inductive Amplivligere Probe
- Probe tip: Used to detect the tone signal.
- Højttaler: Emits the audible tone when a signal is detected.
- Afbryderen: Turns the probe on/off.
- Følsomhedskontrol: Adjusts the detection sensitivity (if applicable, not explicitly mentioned but common for such devices).
4.2. Wire Tracker Tone Generator
- Funktionskontakt: Selects between TONE, OFF (POLARITY), and CONTINUITY modes.
- LINE 1 / LINE 2 Ports: Connectors for testing individual lines.
- POLARITY Indicator: Shows the polarity of the line being tested.
- Prøveemner: Red and black leads with alligator clips for connecting to wires.
- RJ11/RJ45 Port: For connecting to telephone or network cables (implied by images).
5. Specifikationer
| Feature | Specifikation |
|---|---|
| Model | 200EP |
| Materiale | Plast |
| Gevinst | Nominel 30dB |
| Indgangsimpedans | Nominal 100M ohms |
| Metal Needle Tip Resistance | 0 ohm |
| Plastic Prompt Resistance | 300 ohm |
| Batteri (ikke inkluderet) | 1 x 9V DC battery (NEDA 1604, JIS 006P, or IEC 6LR61) |
| Battery Life (Nominal) | 50 timer |
| Driftstemperatur | 0 ℃ - 50 ℃ (32 ℉ - 122 ℉) |
| Vægt | Approximately 300 grams / 10.6 ounces |
| Dimensioner (sonde) | Cirka 231 mm x 55 mm x 28 mm (9.09 tommer x 2.16 tommer x 1.102 tommer) |
| Anvendelse | Maintenance and testing of cables and wires |

Figur 5.1: Induktiv Amplifier Probe Dimensions.
6. Opsætning
6.1. Batteriinstallation
The alloet 200EP Wire Tester Kit requires one 9V DC battery (NEDA 1604, JIS 006P, or IEC 6LR61) for operation. Batteries are not included in the package.
- Locate the battery compartment on the rear side of the Inductive Amplifier Probe.
- Carefully slide open the battery cover.
- Isæt et nyt 9V-batteri, og sørg for korrekt polaritet (+/-) som angivet inde i batterirummet.
- Luk batteridækslet forsvarligt.

Figure 6.1: Battery Compartment on Inductive Amplifier Probe.
7. Betjeningsvejledning
The 200EP Wire Tester Kit offers multiple testing functions for various cable and wire applications.
7.1. Tone Tracing (Cable/Wire Identification)
- Connect the Wire Tracker Tone Generator to the cable you wish to trace. Use the alligator clips for individual wires or the RJ11/RJ45 port for network/telephone cables.
- Set the function switch on the Tone Generator to 'TONE'. The generator will emit an audible tone onto the connected cable.
- Tænd den induktive Amplifier Probe using its power switch.
- Adjust the probe's sensitivity (if available) to an appropriate level.
- Move the insulated probe tip along the suspected cables. When the probe comes close to the cable carrying the tone signal, the speaker on the probe will emit the tone, allowing you to identify the correct cable.

Figure 7.1: Using the Inductive Amplifier Probe for wire tracing.
7.2. Kontinuitetstest
- Connect the Wire Tracker Tone Generator to the two ends of the wire or cable segment you want to test for continuity using the alligator clips.
- Set the function switch on the Tone Generator to 'CONTINUITY'.
- If there is continuity (a complete circuit), the Tone Generator will indicate this, often with an LED or a specific tone.
7.3. Polaritetstestning
- Connect the Wire Tracker Tone Generator to the two ends of the wire or cable segment you want to test for polarity.
- Set the function switch on the Tone Generator to 'OFF (POLARITY)'.
- The POLARITY indicator on the Tone Generator will light up to show the positive or negative polarity of the connected line.
7.4. Clamp Mode test
Klamp mode allows for direct measurement of non-terminal cables. This is particularly useful for telephone and network line testing where direct access to terminals might be limited.
- Connect the Tone Generator to the cable using the appropriate method (e.g., alligator clips to exposed wires).
- Set the Tone Generator to 'TONE' mode.
- Use the Inductive Amplifier Probe to trace the signal along the cable, even if it's not terminated.
8. Vedligeholdelse
- Rensning: Tør enheden af med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Udskiftning af batteri: Replace the 9V battery when the device's performance degrades or if it fails to power on. Always use the specified battery type.
- Opbevaring: Store the device in its storage bag in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.
- Probe tip: If the metal probe tip becomes worn or damaged, replace it with the provided replacement head.
9. Fejlfinding
- Enheden tændes ikke:
- Check if the battery is correctly installed with the right polarity.
- Replace the 9V battery with a new one. - No tone detected by the probe:
- Ensure both the Tone Generator and the Inductive Amplifier Probe are turned on.
- Verify the Tone Generator is set to 'TONE' mode.
- Check the connection between the Tone Generator and the cable.
- Increase the sensitivity of the Inductive Amplifier Probe.
- Ensure the cable is not damaged or broken. - Unøjagtige aflæsninger:
- Ensure connections are secure and clean.
- Replace the battery if it is low, as this can affect performance.
10. Brugertips
- For best results, perform wire tracing in a quiet environment to easily hear the tone.
- When tracing, move the probe slowly along the cable path to avoid missing the signal.
- Always start with a lower sensitivity setting on the probe and gradually increase it if the signal is weak.
- Keep the probe tip clean for optimal contact and signal detection.
11. Garanti og support
For warranty information and technical support, please refer to the seller or the point of purchase. Keep your purchase receipt as proof of purchase.