1. Introduktion

This manual provides detailed instructions for the setup, operation, and maintenance of your Kamoer KCM-B163-ODM High Flow Stepper Motor Peristaltic Pump. This pump is designed for precise liquid transfer in various applications, offering high accuracy and small pulsation.

Nøglefunktioner:

  • Suitable for both viscous and non-viscous liquid transfer.
  • High precision with minimal pulsation.
  • Designed for external instrument panel mounting, allowing for ground detection.
  • Simple structure ensures high reliability.
  • Quick and easy pump tube replacement.
  • Equipped with a high-performance imported stepper motor.

Typiske applikationer:

  • Laboratory experiments
  • Filling and packaging processes
  • Research institutes
  • Fødevare- og drikkevareindustrien

2. Specifikationer

ParameterVærdi
MotorStepmotor
Voltage24V
Flowhastighedsområde17-420 ml/min (typical for B16 tube: 160 ml/min)
Hastighedsområde0.1-300 RPM
Tube Material (Standard)PharMed BPT
InstallationsmetodeODMA (Rubber shock behind the pump)
Rotor3 rotors
PumpehovedmaterialeEngineering plastics
Driftstemperatur0~40℃
DriftsfugtighedMindre end 80 %
Tubing Lifetime (B16)1000 timer
Tubing Working Temperature-51℃~132℃

2.1. Tube Selection Guide

The choice of tubing material is crucial for optimal performance and longevity, especially when handling different liquids. The data below is based on tests with water. For viscous or corrosive liquids, BPT tubing is recommended. Silicone tubing is suitable for neutral liquids and can be customized.

PumpehovedTube (ID x OD)Hastighedsområde (RPM)Flowhastighed (ml/min)Tubing LifetimeTubing Working Temperature
3-rotor Pump headB16 (ID3.2 x OD6.4mm)0.1-3001601000H-51℃~132℃
3-rotor Pump headB25 (ID4.8 x OD8.0mm)0.1-3504521000H-51℃~132℃

3. Komponenter overview

The Kamoer KCM-B163-ODM pump system includes the peristaltic pump head, a stepper motor, a driver board, and a control board with user interface elements.

Kamoer KCM-B163-ODM pump with labeled control board and driver board
Figure 3.1: Kamoer KCM-B163-ODM pump with 2802 Control board and KMD-42B-P Driver board labeled. Flow range 17-420ml/min, compatible with 12V/24V.
Kamoer KCM-B163-ODM pump with labeled LED digital display and control buttons
Figure 3.2: Kamoer KCM-B163-ODM pump showing the LED Digital Display, Flow Speed Button (Black), Start and Stop Button (Green), and Flow Direction Button (Red).

3.1. Driver Board (KMD-42B-P)

The KMD-42B-P driver board manages the stepper motor's operation, ensuring precise control over the pump's speed and direction.

Close-up of KMD-42B-P Driver board
Figur 3.3: Nærbillede view of the KMD-42B-P Driver board.

3.2. Control Board (2802)

The 2802 control board provides the interface for user interaction, including speed adjustment, start/stop, and flow direction control, with an LED digital display for feedback.

Close-up of 2802 Control board
Figur 3.4: Nærbillede view of the 2802 Control board.

4. Opsætning og installation

4.1. Tubing Connection

Connect the appropriate silicone or BPT tubing to the pump head's threaded joints. Ensure a secure fit to prevent leaks.

Threaded joint for tubing connection
Figure 4.1: Detail of the threaded joint for secure tubing connection.

4.2. Elektriske forbindelser

Connect the 2802 Control board to the KMD-42B-P Driver board as per the wiring diagram below. Pay close attention to the voltage limiting resistor (R) required based on your controller's interface voltage.

Wiring diagram for Controller to Driver
Figure 4.2: Wiring diagram for connecting the Controller to the Driver. Note the resistor (R) values: VCC=5V, R=0; VCC=12V, R=1K; VCC=24V, R=2.7K.

Connect the stepper motor to the driver board using the provided wiring. Ensure correct polarity for A+, B+, B-, and A- lines.

Stepper motor wiring diagram
Figure 4.3: Stepper motor wiring showing A+ (Black line), B+ (Blue line), B- (Red line), and A- (Green line) connections.

4.3. Mounting (ODMA Type)

The KCM-B163-ODM pump features an ODMA installation method, which includes a rubber shock absorber behind the pump for stable mounting. Refer to the diagrams for dimensions and wall plate hole size for proper integration into your system.

Installation diagram with dimensions (side view)
Figur 4.4: Side view installation diagram with key dimensions (e.g., 74mm, 81.5mm, 126mm).
Installation diagram with dimensions (front view)
Figur 4.5: Forside view installation diagram with key dimensions (e.g., 15mm, 42±0.15mm, 54±0.15mm, 65mm).
Wall plate hole size diagram
Figure 4.6: Wall plate hole size diagram (56.2mm x 56.2mm with R4.6 corners).

5. Betjeningsvejledning

After connecting the pump to a suitable power adapter, you can control its functions using the integrated buttons and display.

Video 5.1: Demonstration of the KCM-ODM pump's operation, including start/stop, speed adjustment, and flow direction change.
  1. Start/Stop: Tryk på Grøn knap to start or stop the pump.
  2. Strømningsretning: Tryk på Rød knap to change the flow direction.
  3. Flowhastighedsjustering: Brug Black speed control button/knob to adjust the pump's rotating speed. The LED digital display will show the current rotating speed (RPM).

6. Vedligeholdelse

Regular maintenance ensures the longevity and optimal performance of your peristaltic pump.

  • Inspektion af rør: Periodically inspect the pump tubing for any signs of wear, cracks, or degradation. Worn tubing can affect flow accuracy and lead to leaks.
  • Udskiftning af slanger: The pump head is designed for quick and easy replacement of the pump tube. Replace tubing as needed to maintain performance and prevent contamination.
  • Rensning: Keep the pump head and external components clean. Use a damp cloth to wipe surfaces. Avoid using harsh chemicals that could damage the plastic or electronic components.
  • Opbevaring: When not in use for extended periods, store the pump in a clean, dry environment away from direct sunlight and extreme temperatures.

7. Fejlfinding

If you encounter issues with your Kamoer KCM-B163-ODM pump, refer to the following common troubleshooting steps:

  • Pumpen starter ikke:
    - Ensure the power adapter is correctly connected and supplying the correct voltage (24V).
    - Verify that the green Start/Stop button is pressed.
  • Incorrect Flow Rate:
    - Check the setting on the black speed control button/knob and the LED display. Adjust as necessary.
    - Inspect the tubing for any kinks, blockages, or damage that might restrict flow.
    - Ensure the liquid source is sufficient and the tubing is properly submerged.
  • Intet flow:
    - Confirm that the tubing is correctly installed and securely connected to the pump head.
    - Check for air bubbles trapped in the tubing, which can prevent priming.
    - Ensure the liquid reservoir is not empty.
  • Usædvanlig støj:
    - Turn off the pump and inspect the pump head for any foreign objects.
    - Check the motor mounting for any loose screws or components.

8. Brugertips

  • The Kamoer KCM-B163-ODM pump is noted for its super quiet operation.
  • Its flow rate is highly adjustable, typically ranging from 0.1 to 400ml/min depending on the specific tubing and model configuration.
  • Always consider the chemical compatibility of your liquid with the tubing material. For viscous or corrosive liquids, BPT tubing is highly recommended to ensure optimal performance and pump longevity.
  • For precise dosing, ensure the tubing is free from air bubbles and the liquid level in the source container is consistent.

9. Garanti og support

For any questions, technical assistance, or warranty claims, please contact the Kamoer Official Store or your authorized distributor. Provide your product model number and purchase details for efficient support.


Kamoer KCM-B163-ODM High Flow Stepper Motor Peristaltic Pump Operation Guide

Kamoer KCM-B163-ODM High Flow Stepper Motor Peristaltic Pump Operation Guide

0:59 • 1280×720 • betjening

Relaterede dokumenter - KCM-B163-ODM

Preview KCP-KK300-D justerbar peristaltisk pumpe brugermanual
Brugermanual til den justerbare peristaltiske pumpe Kamoer KCP-KK300-D med detaljerede oplysninger om funktioner, specifikationer, driftsforhold, beskrivelse af grænsefladen og sikkerhedsforanstaltninger.
Preview Kamoer UIP WIFI E Smart Peristaltisk Pumpe Brugermanual
Omfattende brugermanual til Kamoer UIP WIFI E Smart peristaltisk pumpe, med detaljerede oplysninger om dens funktioner, driftstilstande (kontinuitet, rationering, fjernbetjening), systemindstillinger, vedligeholdelse og tekniske specifikationer.
Preview Kamoer UIP WIFI E Smart peristaltisk pumpe: Hurtigstartguide og tekniske specifikationer
Lynstartguide og tekniske specifikationer for Kamoer UIP WIFI E Smart peristaltisk pumpe, med detaljerede oplysninger om funktioner, brugerflade, app-tilslutning og garantioplysninger.
Preview Produktmanual til Kamoer M1-STP Smart Peristaltisk Pumpe
Denne manual indeholder detaljerede oplysninger om Kamoer M1-STP Smart Peristaltic Pump, herunder dens funktioner, specifikationer, modeldefinitioner, interfaceforklaringer og tilbehør. Den dækker ydeevnekarakteristika og typiske anvendelser i laboratorie- og industrimiljøer.
Preview Kamoer X4 Doseringspumpe Brugermanual til iOS
Omfattende brugermanual til Kamoer X4 doseringspumpen, der indeholder detaljerede instruktioner om opsætning, iOS-app-forbindelse (direkte og automatisk forbindelse), navigation i softwaregrænsefladen (tid/temperatur, automatisk, manuel, status, mere, kalibrering), vedligeholdelse og teknisk support.
Preview Kamoer M1-STP Smart Peristaltisk Pumpe Brugermanual
Brugermanual til Kamoer M1-STP Smart Peristaltic Pump, med detaljerede oplysninger om dens funktioner, driftstilstande (kontinuerlige og kvantitative), kalibrering og tekniske parametre.