1. Introduktion

The MASTECH MS2138 and MS2138R are professional AC/DC digital clamp meters designed for accurate and reliable electrical measurements. These meters are suitable for a wide range of applications, including testing and maintenance in universities, vocational colleges, refining, communication, manufacturing, petroleum, national defense, electricity, power supply systems, and circuit power equipment. They feature a 4000-count display, auto and manual ranging, and various measurement functions for current, voltage, resistance, capacitance, and frequency.

2. Sikkerhedsoplysninger

Please read and understand all safety information before operating this device. Failure to follow these instructions may result in electric shock, fire, or damage to the meter or the equipment under test.

3. Pakkens indhold

Bekræft at alle genstande er til stede og ubeskadigede:

MASTECH MS2138R Clamp Meter with test leads, carry bag, and user manual
Figure 1: MS2138R Clamp Måler og medfølgende tilbehør.

4. Nøglefunktioner

Icons representing various measurement functions of the clamp måler
Figure 2: Multiple Measurement Functions.

5. Tekniske specifikationer

Measurement Ranges and Accuracy

SpecifikationerRækkeviddeOpløsningNøjagtighed
DC bindtage400mV0.1mV±(1.0 %+2)
4V/40V/400V0.001V/0.01V/0.1V±(0.7 %+2)
600V1V±(0.8 %+2)
AC Voltage400mV/4V/40V/400V0.0001V/0.001V/0.01V/0.1V±(0.8 %+3)
600V1V±(1.0 %+4)
DC-strøm40A/400A/1000A0.01A/0.1A/1A±(3.0 %+6)
AC strøm40A/400A/1000A0.01A/0.1A/1A±(2.5 %+6)
Modstand400Ω/4kΩ/40kΩ/400kΩ0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ±(0.8 %+3)
4MΩ/40MΩ0.001MΩ/0.1MΩ±(1.2 %+3)
Kapacitans40nF / 400nF / 4μF0.01nF / 0.1nF / 0.001μF±(4.0 %+5)
40μF/400μF/4000μF0.01μF/0.1μF/1μF±(4.0 %+5)
Frequency (A)100Hz/1kHz0.01Hz/0.1Hz±(1.5 %+5)
> 1 kHz0.001kHzTake it only as reference
Frekvens (V)100Hz/1kHz/10kHz0.01Hz/0.1Hz/0.001kHz±(1.5 %+5)
> 10 kHz0.01kHzTake it only as reference
Duty Cycle0.1%~99%0.10 %±3.0 %

Generelle specifikationer

Detailed technical specifications table for MASTECH MS2138 and MS2138R clamp meter
Figure 3: Product Parameters and Technical Data.

6. Opsætning

6.1 Batteriinstallation

  1. Ensure the meter is turned off and disconnect any test leads from the input terminals.
  2. Find batteridækslet på bagsiden af ​​måleren.
  3. Brug en skruetrækker til at åbne batterirummet.
  4. Insert three 1.5V AAA batteries, observing the correct polarity (+ and -).
  5. Sæt batterirummets dæksel på igen og fastgør det med skruen.

6.2 Tilslutning af testledninger

For bdtage, resistance, capacitance, frequency (V), diode, and continuity measurements, connect the test leads:

7. Betjeningsvejledning

To operate the clamp meter, turn the rotary switch to the desired function. The meter will automatically select the appropriate range unless manual ranging is activated.

7.1 AC/DC strømmåling (Clamping)

For at måle AC- eller DC-strøm skal du bruge cl-knappen.amp kæbe:

  1. Turn the rotary switch to the "A~" (AC Current) or "A=" (DC Current) position.
  2. Åbn clamp kæben ved at trykke på aftrækkeren.
  3. Enclose only one conductor (wire) of the circuit within the clamp kæbe. Sørg for, at kæben er helt lukket.
  4. Aflæs den aktuelle værdi på displayet.
  5. For DC current, the MS2138R model features a DCA automatic zero return key for accurate readings.
Person using the clamp meter to measure high AC current on a thick cable
Figure 4: High AC Current Measurement.

7.2 AC/DC Voltage Måling

Til at måle AC eller DC voltage:

  1. Tilslut testledningerne som beskrevet i afsnit 6.2.
  2. Drej drejekontakten til "V~" (AC-volumen)tage) eller "V=" (DC-volumentage) stilling.
  3. Touch the red test lead to the positive side of the circuit and the black test lead to the negative side (or neutral/ground for AC).
  4. Læs bindtage -værdi på displayet.
Person using the clamp meter to measure AC voltage i et elektrisk panel
Figur 5: AC Voltage-test.

7.3 Modstandsmåling

Sådan måles modstand:

  1. Sørg for, at kredsløbet er spændingsløst, før du måler modstanden.
  2. Tilslut testledningerne som beskrevet i afsnit 6.2.
  3. Turn the rotary switch to the "Ω" (Resistance) position.
  4. Touch the test leads across the component or circuit to be measured.
  5. Læs modstandsværdien på displayet.
Person using the clamp meter to measure resistance on an electric motor
Figure 6: Resistance Test.

7.4 Kapacitansmåling

Sådan måles kapacitans:

  1. Sørg for, at kondensatoren er helt afladet før måling.
  2. Tilslut testledningerne som beskrevet i afsnit 6.2.
  3. Turn the rotary switch to the "μF" (Capacitance) position.
  4. Touch the test leads across the capacitor terminals.
  5. Læs kapacitansværdien på displayet.
Person using the clamp meter to measure capacitance on a fan motor
Figure 7: Capacitance Testing.

7.5 Frekvens- og duty cycle-måling

To measure frequency (Hz) or duty cycle (%):

  1. Connect the test leads as described in Section 6.2 for voltage-based frequency, or use the clamp for current-based frequency.
  2. Turn the rotary switch to the "Hz%" position.
  3. Apply the test leads or clamp the conductor to the signal source.
  4. Read the frequency or duty cycle value on the display. Use the "FUNC" button to toggle between Hz and %.
Person using the clamp meter to measure frequency on an electrical circuit
Figure 8: Frequency Test.

7.6 Diodetest

Sådan tester du dioder:

  1. Sørg for, at kredsløbet er spændingsløst.
  2. Tilslut testledningerne som beskrevet i afsnit 6.2.
  3. Turn the rotary switch to the diode symbol position.
  4. Place the red test lead on the anode and the black test lead on the cathode of the diode.
  5. Læs videre bindtage drop on the display. Reverse the leads to check for open circuit.
Person using the clamp meter to perform a diode test on an electronic component
Figure 9: Diode Test.

7.7 Kontinuitetstest

For at kontrollere kontinuitet:

  1. Sørg for, at kredsløbet er spændingsløst.
  2. Tilslut testledningerne som beskrevet i afsnit 6.2.
  3. Turn the rotary switch to the continuity symbol position.
  4. Touch the test leads across the circuit or component.
  5. A buzzer will sound if continuity is detected (resistance less than 50 ±20Ω).
Person using the clamp meter to perform a continuity test on a wire
Figure 10: Continuity Test.

7.8 Yderligere funktioner

8. Vedligeholdelse

8.1 Rengøring

Tør måleren c afasing med annonceamp klud og mildt rengøringsmiddel. Brug ikke slibemidler eller opløsningsmidler. Sørg for, at måleren er helt tør før brug.

8.2 Udskiftning af batteri

When the low battery indicator appears on the display, replace the batteries as described in Section 6.1. Use three new 1.5V AAA batteries.

8.3 Opbevaring

If the meter is not used for an extended period, remove the batteries to prevent leakage. Store the meter in its carry bag in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Fejlfinding

ProblemMulig årsagLøsning
Måleren tænder ikkeDøde eller forkert installerede batterierKontroller batteripolariteten, og udskift batterierne om nødvendigt.
No reading or "OL" (Overload) displayedIncorrect function selected, out of range, or open circuitSelect the correct function. If in manual range, switch to a higher range. Check for open circuits or ensure test leads are properly connected.
Unøjagtige aflæsningerLow battery, dirty test leads, or external interferenceUdskift batterierne. Rengør testledningerne. Flyt væk fra stærke elektromagnetiske felter.
Continuity buzzer not workingResistance too high, or function not selectedEnsure resistance is below 50 ±20Ω. Select continuity function.

10. Brugertips

Der var ingen specifikke brugertips tilgængelige fra de angivneviews or Q&A. Always refer to the detailed operating instructions for best results.

11. Garanti og support

For warranty information and technical support, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.

Relaterede dokumenter - MS2138 / MS2138R

Preview MASTECH MS2016A Lækagerensamp Målerens betjeningsvejledning
Omfattende betjeningsmanual til MASTECH MS2016A AC-lækagefiltretamp Måler, der dækker sikkerhedsoplysninger, specifikationer, betjeningsvejledning, vedligeholdelse og tilbehør. Funktioner inkluderer AC/DC-volumentage. modstand, kapacitans, kontinuitet, diode og temperaturmålinger.
Preview MASTECH MS2108 AC/DC Clamp Vejledning til hurtig start af måleren
En kortfattet hurtigstartguide til MASTECH MS2108 AC/DC Clamp Måler med detaljerede sikkerhedsforanstaltninger, tekniske specifikationer og grundlæggende brugsanvisning til måling af volumentage, strøm, modstand, kapacitans og frekvens.
Preview MASTECH MS2203 Trefaset Power Clamp Vejledning til hurtig start af måleren
Dette dokument indeholder en hurtigstartvejledning til MASTECH MS2203 trefaset strømforsyning.amp Måler. Den indeholder vigtige sikkerhedsforanstaltninger, detaljerede specifikationer og trinvise instruktioner til måling af AC-volumen.tage.g. vekselstrøm og enfaset/trefasestrøm. Lær, hvordan du bruger måleren til forskellige elektriske testapplikationer.
Preview MASTECH MS8211D Pen-type digitalt multimeter Hurtigstartguide
En hurtigstartguide til MASTECH MS8211D digitalt multimeter af pentypen, der indeholder vigtige sikkerhedsoplysninger, tekniske specifikationer og grundlæggende betjeningsinstruktioner til vol.tage, strøm-, modstands- og logiktest.
Preview MASTECH MS2205 Trefaset Power Clamp Vejledning til hurtig start af måleren
En hurtigstartguide til MASTECH MS2205 trefaset strømforsyningamp Måler, der dækker sikkerhedsforanstaltninger, specifikationer og tilslutningsdiagrammer til enfasede og trefasede effektmålinger.
Preview MASTECH MS2205 Digital Clamp Målerens betjeningsmanual - Vejledning til effekt- og harmonisk måling
Omfattende betjeningsmanual til MASTECH MS2205 Digital Clamp Måler. Denne vejledning dækker sikkerhedsinstruktioner, funktioner og betjeningsprocedurer for AC-volumenmålertage. strøm, effekt, harmoniske og fasefølgemålinger, sammen med tekniske specifikationer og vedligeholdelsesdetaljer.