1. Introduktion
The MASTECH MS2138 and MS2138R are professional AC/DC digital clamp meters designed for accurate and reliable electrical measurements. These meters are suitable for a wide range of applications, including testing and maintenance in universities, vocational colleges, refining, communication, manufacturing, petroleum, national defense, electricity, power supply systems, and circuit power equipment. They feature a 4000-count display, auto and manual ranging, and various measurement functions for current, voltage, resistance, capacitance, and frequency.
2. Sikkerhedsoplysninger
Please read and understand all safety information before operating this device. Failure to follow these instructions may result in electric shock, fire, or damage to the meter or the equipment under test.
- Overhold altid lokale og nationale sikkerhedsforskrifter.
- Brug ikke måleren, hvis den ser beskadiget ud, eller hvis testledningerne er beskadigede.
- Ensure the rotary switch is in the correct position for the desired measurement before connecting the test leads.
- Påfør ikke mere end den nominelle voltage, som markeret på måleren, mellem terminaler eller mellem enhver terminal og jord.
- Vær forsigtig, når du arbejder med voltagover 60V DC eller 30V AC RMS, da disse udgør en fare for stød.
- Ved strømmåling med clamp, ensure only one wire in the circuit is clampudg.
- The device has a Safety Rating of CAT III 600V.
3. Pakkens indhold
Bekræft at alle genstande er til stede og ubeskadigede:
- MASTECH MS2138 or MS2138R Digital Clamp Måler
- Test leads (one red, one black)
- Bæretaske
- Brugermanual
- *Note: 3x1.5V AAA batteries are required but not included.*

4. Nøglefunktioner
- Display: 4000 tæller
- Jaw Opening: Φ40mm / 1.6"
- Ranging: Auto & Manual
- Auto Power Off funktion
- Diode åben volumentage: 2.8V
- Continuity Buzzer: Less than 50 ±20Ω
- Relativ måletilstand
- Data Hold funktion
- Indikator for lavt batteriniveau
- Skærmbaggrundsbelysning til forhold med svagt lys
- Work Light for illuminating the measurement area
- Søjlediagramvisning
- True Root Mean Square (True RMS) for MS2138R model
- DCA automatic zero return key (MS2138R only)

5. Tekniske specifikationer
Measurement Ranges and Accuracy
| Specifikationer | Rækkevidde | Opløsning | Nøjagtighed |
|---|---|---|---|
| DC bindtage | 400mV | 0.1mV | ±(1.0 %+2) |
| 4V/40V/400V | 0.001V/0.01V/0.1V | ±(0.7 %+2) | |
| 600V | 1V | ±(0.8 %+2) | |
| AC Voltage | 400mV/4V/40V/400V | 0.0001V/0.001V/0.01V/0.1V | ±(0.8 %+3) |
| 600V | 1V | ±(1.0 %+4) | |
| DC-strøm | 40A/400A/1000A | 0.01A/0.1A/1A | ±(3.0 %+6) |
| AC strøm | 40A/400A/1000A | 0.01A/0.1A/1A | ±(2.5 %+6) |
| Modstand | 400Ω/4kΩ/40kΩ/400kΩ | 0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ | ±(0.8 %+3) |
| 4MΩ/40MΩ | 0.001MΩ/0.1MΩ | ±(1.2 %+3) | |
| Kapacitans | 40nF / 400nF / 4μF | 0.01nF / 0.1nF / 0.001μF | ±(4.0 %+5) |
| 40μF/400μF/4000μF | 0.01μF/0.1μF/1μF | ±(4.0 %+5) | |
| Frequency (A) | 100Hz/1kHz | 0.01Hz/0.1Hz | ±(1.5 %+5) |
| > 1 kHz | 0.001kHz | Take it only as reference | |
| Frekvens (V) | 100Hz/1kHz/10kHz | 0.01Hz/0.1Hz/0.001kHz | ±(1.5 %+5) |
| > 10 kHz | 0.01kHz | Take it only as reference | |
| Duty Cycle | 0.1%~99% | 0.10 % | ±3.0 % |
Generelle specifikationer
- Power Supply: 3 × 1.5V AAA Batteries
- Product Size: 222mm × 86mm × 32mm (8.74" × 3.38" × 1.26")
- Product Weight: 323g (0.71lb)
- Certification: RoHS
- Safety Rating: CAT III 600V
- Display Type: Digital Only

6. Opsætning
6.1 Batteriinstallation
- Ensure the meter is turned off and disconnect any test leads from the input terminals.
- Find batteridækslet på bagsiden af måleren.
- Brug en skruetrækker til at åbne batterirummet.
- Insert three 1.5V AAA batteries, observing the correct polarity (+ and -).
- Sæt batterirummets dæksel på igen og fastgør det med skruen.
6.2 Tilslutning af testledninger
For bdtage, resistance, capacitance, frequency (V), diode, and continuity measurements, connect the test leads:
- Sæt den sorte testledning i "COM" (fælles) indgangsstikket.
- Insert the red test lead into the "VΩHz" input jack.
7. Betjeningsvejledning
To operate the clamp meter, turn the rotary switch to the desired function. The meter will automatically select the appropriate range unless manual ranging is activated.
7.1 AC/DC strømmåling (Clamping)
For at måle AC- eller DC-strøm skal du bruge cl-knappen.amp kæbe:
- Turn the rotary switch to the "A~" (AC Current) or "A=" (DC Current) position.
- Åbn clamp kæben ved at trykke på aftrækkeren.
- Enclose only one conductor (wire) of the circuit within the clamp kæbe. Sørg for, at kæben er helt lukket.
- Aflæs den aktuelle værdi på displayet.
- For DC current, the MS2138R model features a DCA automatic zero return key for accurate readings.

7.2 AC/DC Voltage Måling
Til at måle AC eller DC voltage:
- Tilslut testledningerne som beskrevet i afsnit 6.2.
- Drej drejekontakten til "V~" (AC-volumen)tage) eller "V=" (DC-volumentage) stilling.
- Touch the red test lead to the positive side of the circuit and the black test lead to the negative side (or neutral/ground for AC).
- Læs bindtage -værdi på displayet.

7.3 Modstandsmåling
Sådan måles modstand:
- Sørg for, at kredsløbet er spændingsløst, før du måler modstanden.
- Tilslut testledningerne som beskrevet i afsnit 6.2.
- Turn the rotary switch to the "Ω" (Resistance) position.
- Touch the test leads across the component or circuit to be measured.
- Læs modstandsværdien på displayet.

7.4 Kapacitansmåling
Sådan måles kapacitans:
- Sørg for, at kondensatoren er helt afladet før måling.
- Tilslut testledningerne som beskrevet i afsnit 6.2.
- Turn the rotary switch to the "μF" (Capacitance) position.
- Touch the test leads across the capacitor terminals.
- Læs kapacitansværdien på displayet.

7.5 Frekvens- og duty cycle-måling
To measure frequency (Hz) or duty cycle (%):
- Connect the test leads as described in Section 6.2 for voltage-based frequency, or use the clamp for current-based frequency.
- Turn the rotary switch to the "Hz%" position.
- Apply the test leads or clamp the conductor to the signal source.
- Read the frequency or duty cycle value on the display. Use the "FUNC" button to toggle between Hz and %.

7.6 Diodetest
Sådan tester du dioder:
- Sørg for, at kredsløbet er spændingsløst.
- Tilslut testledningerne som beskrevet i afsnit 6.2.
- Turn the rotary switch to the diode symbol position.
- Place the red test lead on the anode and the black test lead on the cathode of the diode.
- Læs videre bindtage drop on the display. Reverse the leads to check for open circuit.

7.7 Kontinuitetstest
For at kontrollere kontinuitet:
- Sørg for, at kredsløbet er spændingsløst.
- Tilslut testledningerne som beskrevet i afsnit 6.2.
- Turn the rotary switch to the continuity symbol position.
- Touch the test leads across the circuit or component.
- A buzzer will sound if continuity is detected (resistance less than 50 ±20Ω).

7.8 Yderligere funktioner
- Data Hold (HOLD button): Tryk for at fryse den aktuelle aflæsning på displayet. Tryk igen for at slippe.
- Relative Measurement (REL button): Press to store the current reading as a reference value. Subsequent measurements will be displayed as a difference from this reference.
- Backlight / Work Light: Activate the display backlight and/or work light for improved visibility in dark environments.
- Automatisk sluk: Måleren slukker automatisk efter en periode med inaktivitet for at spare på batteriet.
8. Vedligeholdelse
8.1 Rengøring
Tør måleren c afasing med annonceamp klud og mildt rengøringsmiddel. Brug ikke slibemidler eller opløsningsmidler. Sørg for, at måleren er helt tør før brug.
8.2 Udskiftning af batteri
When the low battery indicator appears on the display, replace the batteries as described in Section 6.1. Use three new 1.5V AAA batteries.
8.3 Opbevaring
If the meter is not used for an extended period, remove the batteries to prevent leakage. Store the meter in its carry bag in a cool, dry place, away from direct sunlight and extreme temperatures.
9. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Måleren tænder ikke | Døde eller forkert installerede batterier | Kontroller batteripolariteten, og udskift batterierne om nødvendigt. |
| No reading or "OL" (Overload) displayed | Incorrect function selected, out of range, or open circuit | Select the correct function. If in manual range, switch to a higher range. Check for open circuits or ensure test leads are properly connected. |
| Unøjagtige aflæsninger | Low battery, dirty test leads, or external interference | Udskift batterierne. Rengør testledningerne. Flyt væk fra stærke elektromagnetiske felter. |
| Continuity buzzer not working | Resistance too high, or function not selected | Ensure resistance is below 50 ±20Ω. Select continuity function. |
10. Brugertips
Der var ingen specifikke brugertips tilgængelige fra de angivneviews or Q&A. Always refer to the detailed operating instructions for best results.
11. Garanti og support
For warranty information and technical support, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.