1. Velkommen
The EARU EASEM-D Multi-Circuit Power Meter helps you monitor the amount of electricity consumed and produced in your facility by connecting current transformers (CT clamps) to the power cable.
Denne guide giver en overview of the product and assists you with the initial setup and installation.
Nøglefunktioner:
- Tuya compliant: Supports automation with other Tuya devices.
- Compatible with Single, Split-Phase 120/240VAC, and 3-Phase/4-wire 480Y/277VAC electricity systems.
- Remotely monitors whole home energy and up to 16 individual circuits with 50A Sub CTs (e.g., solar, lighting, receptacles).
- Bi-Directional measurement.
- Realtidsmåling af Voltage, Strøm, effektfaktor, aktiv effekt og frekvens.
- Historical data of Energy Consumed and Energy Production.
2. Sikkerhedshåndtering
WARNING: Failure to follow these safety notices could result in fire, electric shock, other injuries, or damage to the Power Meter and other property. Read all the safety notices below before using the Power Meter.
- Undgå høj luftfugtighed eller ekstreme temperaturer.
- Undgå langvarig udsættelse for direkte sollys eller stærkt ultraviolet lys.
- Undlad at tabe eller udsætte enheden for intense vibrationer.
- Du må ikke skille enheden ad eller prøve at reparere den på egen hånd.
- Udsæt ikke enheden eller dens tilbehør for brændbare væsker, gasser eller andre eksplosive stoffer.
Important Safety Information for Installation:
- Strømmåleren må kun installeres og serviceres af kvalificeret elektrisk personale.
- Rør ikke ved terminalerne på enheden under test.
- Sluk for strømmen, før du tilslutter eller frakobler den til en hjælpeenhed.
- Dobbelttjek, at strømmen er slukket med en korrekt nominel voltage sensorenhed.
Manglende overholdelse af disse instruktioner vil resultere i dødsfald eller alvorlig personskade.
3. Lær din enhed at kende
The EARU EASEM-D Multi-Circuit Power Meter consists of the main unit and various accessories. Familiarize yourself with each component:

Figur 1: Produktkomponenter
Hovedenhed overview:

Figure 2: Main Unit Ports
- LED-indikator: Provides status information (see Troubleshooting section).
- 3.5mm Audio Ports (Top): Inputs for Main CTs (L1/A, L2/B, L3/C).
- 2.5mm Audio Ports (Sides): Inputs for Sub CTs.
- Antennestik: For connecting the external antenna.
- Power Input Port (Bottom): Til tilslutning af strømkablet.
- Nulstil knap: Used for resetting the device (see Troubleshooting section).
4. Tekniske specifikationer

Figur 3: Produktdimensioner og parametre
Trådløs forbindelse
| Feature | Specifikation |
|---|---|
| Wi-Fi | 802.11 b/g/n @ 2.4 GHz |
| RF-egenskaber | Operating frequency: 2.4GHz, External magnetic antenna |
Fysiske specifikationer
| Feature | Specifikation |
|---|---|
| Operation Voltage | 90~480 Vac 50/60 Hz |
| Nominel strøm | 200A / 300A (depending on model) |
| Målenøjagtighed | ±2 % |
| Understøttede systemer | Single-Phase up to 277VAC line-neutral, Split-Phase 120/240VAC, Three-Phase up to 480Y/277VAC (No Delta/wye/Y/Star Connection) |
| Rapporteringscyklus | Hvert 15. sekund |
| Driftstemperatur | -20℃~+55℃ |
| Fugtighed | ≤ 90% ikke-kondenserende |
| Dimensioner | 111.3(L) x 81.2(B) x 41.4(H) mm |
| Batteri inkluderet | Ingen |
| Meget bekymret kemikalie | Ingen |
| Certificering | CE, FCC |
CT Clamp Specifikationer:
| Model | L (mm) | W (mm) | H (mm) | Φ (mm) | Vægt (g) |
|---|---|---|---|---|---|
| 50A | 26 | 24 | 42 | 10 | 57 |
| 200A / 300A | 34 | 45 | 66 | 24 | 160 |
5. Installation
Note: The Power Meter must be installed and serviced only by qualified electrical personnel. Always turn off power before installation.
5.1. Sluk for strømmen
You need to turn off the main breaker in your electric panel to shut off all of the power in your home. However, the service mains are always live! Then remove screws securing the cover to the panel to access the circuit breakers.

Figure 4: Turning off Main Breaker
5.2. Find a Spot for Power Meter
Find a suitable spot for the Power Meter. You can fit it within your electrical panel or use the mounting bracket to fix it on the wall outside the electrical panel if there is no room.

Figur 5: Monteringsmuligheder
5.3. Installer antennen
Locate the External Antenna outside the electrical panel to ensure that the Power Meter signal is not blocked by metal. The base of the antenna has a magnet and can be adsorbed on iron materials. After that, screw the External Antenna to the Antenna connector.
Hvis du installerer strømmåleren i det elektriske panel, kan du bruge en skruetrækker til at udstanse et knockout-dæksel i det elektriske panel. Før derefter det eksterne antennekabel gennem hullet.

Figure 6: Antenna Installation
5.4. Clamp Main CTs around Service Mains
1. Open the clasps on the Main CTs (3.5mm audio plug) to see the arrow (P1→P2 or K→L) or find it on the sticker on the outside of the clamp. This indicates the direction of the CT.

Figur 7: CT Clamp Retning
2. Clamp one Main CT on each main service line. Make sure the arrow on the CT must point towards the breakers! Your system may have 1, 2, or 3 main service lines, and a corresponding number of Main CTs are required.

Figure 8: Main CT Installation (3-Phase)
3. If you have Line/Service-side tap solar, the Main CT must be clamped mellem elmåleren og indgående feeds fra inverteren.

Figure 9: Main CT Installation with Solar
4. Insert each 3.5mm audio plug of the Main CT into the corresponding audio jack on the top of the Power Meter. The jacks are labeled L1/A, L2/B, and L3/C.

Figure 10: Main CT Plug Connections
5.5. Tilslut strømkablet
Tilslut strømkablet i bunden af hovedenheden, indtil det klikker på plads.

Figur 11: Strømkabeltilslutning
Secure the N wire from the power cable to the neutral bus bar and the L1 wire to the L1/A breaker pole.
For 3-Phase systems, secure the L2, L3 wires corresponding to the L2/B, L3/C breaker poles.
For Split-Phase systems, only secure the L2 wire to the L2/B breaker pole. The L3 wire needs to connect to the neutral bus bar.
For Single Phase systems, the L2 and L3 wires need to connect to the neutral bus bar.
5.6. Clamp Sub CTs around the Circuit (Optional)
If you don't have Sub CTs (2.5mm audio plug), skip this step.
1. Open the clasps on the Sub CTs to see the arrow (P1→P2 or K→L) or find it on the sticker on the outside of the clamp. This indicates the direction of the CT.

Figure 12: Sub CT Clamp Retning
2. Clamp each Sub CT around the circuit you wish to monitor. Make sure the arrow on the CT must point towards the load or Inverter!

Figure 13: Sub CT Installation
Note: If the circuit you are monitoring can generate energy (such as an Inverter), after all wiring is completed, you must manually set the phase of the circuit in the app settings, otherwise the power measurement will be incorrect.
3. Insert each 2.5mm audio plug of the Sub CT into the audio jack on the side of the Power Meter. Remember the number of the audio jack connected to the circuit you are measuring, and you may need to match it in your app.
5.7. Wiring Reference Diagrams
Refer to the following diagrams for common wiring configurations:

Figure 14: 3-Phase Wiring (Most in European 3-phase homes and US Commercial systems)

Figure 15: Split-Phase Wiring with Load Monitoring (Most in US homes)

Figure 16: Split-Phase Wiring with Solar Monitoring (Most in US homes)

Figure 17: Single Phase Wiring (Most in European 1-phase homes)
6. Montering
The mounting bracket supports DIN-rail installation. You can click the three hooks on the mounting bracket onto the DIN-rail.

Figure 18: Mounting Bracket to DIN-Rail
Locate the hooks of the mounting bracket and line up the hooks with the mounting holes on the Power Meter. Fit the hooks into the mounting holes as shown in the picture. Installation is now completed.
7. Konfigurer netværk
The device uses the Smart Life app for network configuration and monitoring. Note that the network cannot support 5GHz Wi-Fi!
7.1. Download app
Hent venligst applikationen: Smart liv from your App Store or App Market. You can also scan the QR code below to download and install.

Figure 19: Smart Life App QR Code
7.2. Network Configuration Methods
Here are three methods for device network configuration:
Method 1: Automatic Scan (Recommended)
- After the device is installed, power on the power clamp.
- Reset the device: Press and hold the reset button for 5 seconds until the LED indicator flashes red 3 times quickly.
- Open the Smart Life app and click the 'Scan' button in the upper right corner of the App Home page.
- The app will automatically scan for nearby devices and a prompt box will pop up. Click 'Add'.
- Enter your home Wi-Fi account and password (2.4GHz only) and click 'Next'.
- Wait for the device to be added and click 'Done'. The device has successfully configured the network.
Video: Installation and Network Configuration Guide
Method 2: Manual Scan with QR Code
- After the device is installed, power on the power clamp.
- Reset the device: Press and hold the reset button until the LED flashes red quickly 3 times.
- Open the manual to page 20 to see the QR code.
- Open the Smart Life app and click the 'Scan' button in the upper right corner of the App Home page. Scan the QR code from the manual.
- A prompt box will pop up. Click 'Add'.
- Enter your home Wi-Fi account and password (2.4GHz only) and click 'Next'.
- Wait for the device to be added and click 'Done'. The device has successfully configured the network.
Method 3: Manual Add with Bluetooth
- After the device is installed, power on the power clamp.
- Sørg for, at LED-indikatoren blinker grønt. Hvis ikke, skal du nulstille den.
- Open the Smart Life app and turn on Bluetooth on your phone.
- Open the app and click the '+' on the top right of the home page to add the device.
- Find the 'Energy' option and click 'Switch Module (Wi-Fi)' in the subdirectory 'Breaker'.
- Enter your home Wi-Fi account and password (2.4GHz only) and click 'Next'.
- Click 'Confirm the indicator is blinking'.
- The device indicator light flashes quickly, click 'Blink Quickly'.
- Wait for it to be added and click 'Done'. The device has successfully configured the network.
8. Operating the Device via Smart Life App
Once successfully configured, you can monitor and control your power meter through the Smart Life app.
8.1. Overvågning i realtid
The app provides real-time data on energy consumption and production. You can view:
- Net Usage, Solar Usage, Home Usage.
- Energy 'To Grid' and 'From Grid'.
- Total Active Power, Total Current, Frequency.
- Individual circuit data (Active Power, Current, Voltagog).

Figure 20: App Home Screen - Energy Overview
8.2. Historical Data and Charts
Access historical data and charts to track energy trends over time (Day, Week, Month, Year).

Figure 21: App Charts and Historical Data
8.3. Indstillinger og konfiguration
Within the app settings, you can configure various parameters:
- Circuit Setting: Enable or disable individual circuits for monitoring.
- Solar Setting: Configure settings related to solar production monitoring.
- Sats: Set unified price per kWh and billing cycle start.
- Enhed: Select energy units (e.g., kWh, Amps).

Figure 22: App Settings
8.4. Stemmekontrol
The device supports voice control through Google Assistant and Amazon Alexa, allowing for hands-free operation.

Figur 23: Integration af stemmestyring
9. Vedligeholdelse
The EARU EASEM-D Multi-Circuit Power Meter is designed for low maintenance. Keep the device clean and free from dust. Ensure all connections are secure. No user-serviceable parts are inside the main unit; do not attempt to open or repair it.
10. Fejlfinding
10.1. Nulstil knap
Press and hold the reset button for 5 seconds until the LED indicator flashes red 3 times quickly to restore the Power Meter to default factory settings (energy data will not be cleared).
Hvis du vil slette energidataene, skal du slette enheden og slette data på appen og derefter tilføje dem igen.
10.2. LED-indikatorstatus
The LED status gives the following information about the Power Meter:
| LED-status | Hvad det betyder |
|---|---|
| Grøn LED blinker | Venter på parring |
| Grøn LED lyser konstant | Enheden har oprettet forbindelse til skyen. |
| Rød LED lyser konstant | Enheden er forbundet til routeren, men kunne ikke oprette forbindelse til skyen. |
| Rød LED blinker | Wi-Fi er blevet konfigureret, men det lykkedes ikke at oprette forbindelse til routeren. |
11. Brugertips
- Integration af hjemmeassistent: As the device is Tuya compliant, it may be possible to integrate it with Home Assistant or other smart home platforms that support Tuya devices. Check the specific integration guides for your chosen platform.
- Wi-Fi-netværk: Remember that the device only supports 2.4GHz Wi-Fi networks. Ensure your router is configured to provide a 2.4GHz band or that your phone is connected to the 2.4GHz band during setup.
12. Garanti og support
For warranty information, technical support, or service inquiries, please contact EARU customer service or refer to the official product page where you purchased the device. Keep your purchase receipt as proof of purchase.