1. Introduktion
This manual provides detailed instructions for the installation, operation, and maintenance of your PowMr MPPT Solar Charge Controller. This advanced Maximum Power Point Tracking (MPPT) solar charge controller is designed to efficiently charge various battery types from solar panels, ensuring optimal performance and extending battery life. Please read this manual carefully before using the product to ensure safe and correct operation.
2. Nøglefunktioner
- Advanced MPPT Technology: Achieves tracking efficiency of no less than 99.5% and maximum conversion efficiency up to 97%.
- Automatisk systemvolumentage Recognition: Supports 12V, 24V, 36V, and 48V battery systems automatically.
- Wide Battery Compatibility: Suitable for Sealed Lead-acid, Vented Gel, AGM, NiCd, Lithium, Flooded, and user-defined battery types.
- Multi-Stage Charging: Features a 4-stage PWM charging algorithm (Bulk, Boost, Float, Equalization) to prolong battery lifecycle.
- Integrated LCD Display: Backlit LCD screen for clear display of operating parameters and easy configuration.
- Temperature Sensor Port: Includes a temperature sensor for accurate battery temperature compensation during charging.
- Efficient Cooling System: Equipped with a fan cooling system utilizing bearing technologies for extended life (up to 5000 hours) and high-airflow exhaust to ventilate heat and dust.
- Solar Light Control Mode: Offers various load control options including Manual Mode (24H), Solar Light Control Mode (Sunset-Sunrise), and Solar Light + Time Control (Sunset on + time, Sunrise off).
- Dual USB Ports: (Available on 20A/30A/40A models) For convenient charging of external devices.
- Parallel Function: (Available on 60A Pro model) Supports up to 12 units in parallel for increased capacity.
3. Tekniske specifikationer
| Feature | 20A | 30A | 40A | 60A Standard | 60A New | 60A Pro |
|---|---|---|---|---|---|---|
| Max Open Voltage af PV-modul | 60V | 75V | 100V | 160V jævnstrøm | ||
| Input bindtage Range (12V System) | N/A | 20V~80V | ||||
| Input bindtage Range (24V System) | N/A | 37V~105V | ||||
| Input bindtage Range (36V System) | N/A | 50V~160V | ||||
| Input bindtage Range (48V System) | N/A | 72V~160V | ||||
| System Voltage | 12V/24V | 12V/24V/36V/48V | ||||
| Max. Input Power (12V) | 260W | 390W | 520W | 720W | ||
| Max. Input Power (24V) | 520W | 780W | 1040W | 1440W | ||
| Max. Input Power (36V) | N/A | 2100W | ||||
| Max. Input Power (48V) | N/A | 2800W | ||||
| Opladningsteknologi | MPPT | |||||
| Voltage Batteriets rækkevidde | 8-32V | DC9V~DC60V | ||||
| Batteritype | User default, Sealed, Flooded, GEL, LiFePO4 | |||||
| Parallel funktion | Ingen | Ja, op til 12 enheder | ||||
| Opladningsalgoritme | 3 stages | |||||
Note: Some specifications may vary slightly between specific models (Standard, New, Pro) within the same amperage rating. Refer to the product label for precise details.
4. Pakkens indhold
- PowMr MPPT Solar Charge Controller (selected model)
- Brugermanual
- Monteringsskruer
- Temperature Sensor (for models with dedicated port)
Video: Udpakning og overview of the PowMr MPPT Solar Charge Controller.
5. Sikkerhedsinstruktioner
- Læs alle instruktioner omhyggeligt før installation og drift.
- Sørg for tilstrækkelig ventilation omkring controlleren for at forhindre overophedning.
- Always connect the battery to the controller FIRST, and disconnect it LAST.
- Ensure correct polarity when connecting wires to avoid damage to the controller and other components.
- Use appropriate wire gauges for all connections to handle the expected current.
- Install the controller in a dry, well-protected area, away from direct sunlight, moisture, and corrosive environments.
- Forsøg ikke selv at reparere eller modificere controlleren. Kontakt kvalificeret personale for service.
6. Installation og ledningsføring
6.1. Montering af controlleren
Mount the solar charge controller vertically on a wall or other suitable surface. Ensure there is adequate clearance around the unit for proper airflow and cooling. Avoid mounting in direct sunlight or areas with high humidity.
6.2. Ledningstrin
Follow these steps for safe and correct wiring. Always connect the battery first and disconnect it last.
- Wire the Battery: Connect the battery cables to the battery terminals on the controller. Ensure correct polarity (positive to positive, negative to negative). Tighten the screws securely.
- Wire Solar Panels: Connect the solar panel cables to the PV terminals on the controller. Ensure correct polarity.
- Connect DC Load (Optional): If using a DC load, connect its cables to the load terminals on the controller.
- Connect Temperature Sensor (if applicable): Plug the temperature sensor into its designated port on the controller. This ensures accurate battery temperature compensation.

Image: Visual guide for opening the cover and wiring the battery and PV panels.

Image: Comprehensive wiring diagram showing connections for PV panels, battery, DC load, AC load via inverter, and parallel support for Pro models.

Image: Detail of the temperature sensor port, indicating plug-and-play functionality.
7. Betjening
7.1. LCD-display og navigation
The controller features an LCD display for monitoring system status and adjusting parameters. Use the buttons (PRG/ESC, Up, Down, ENTER) to navigate through menus and make selections.

Billede: Overview of the LCD display and its various screens for monitoring and setting parameters.
7.2. Arbejdstilstande
The controller supports several working modes for load management:
- Night Mode (3.0): No charging occurs.
- MPPT Mode (4.0): Standard Maximum Power Point Tracking for optimal solar charging.
- Absorption Mode (7.0): Batteriopladning stage where voltage holdes konstant, mens strømmen aftager.
- Floating Mode (8.0): Battery is fully charged, and charging voltage is reduced to a lower level to maintain full charge.
Additionally, Solar Light Control modes are available:
- Sollysstyringstilstand: Load turns on at sunset and off at sunrise.
- Sollys + Tidsstyring: Load turns on at sunset and off after a set duration or at sunrise.

Billede: Detaljeret view of working modes and fan cooling system.
7.3. Valg af batteritype
It is crucial to select the correct battery type in the controller settings to ensure proper charging and prevent damage to your batteries. The controller supports User default, Sealed, Flooded, GEL, and LiFePO4 battery types. Consult your battery manufacturer's specifications for recommended charging parameters.

Image: Illustration of compatible battery types and the 4-stage opladningsproces.
8. Vedligeholdelse
- Regelmæssig inspektion: Kontrollér regelmæssigt alle ledningsforbindelser for tæthed og korrosion.
- Renhed: Hold controlleren ren og fri for støv og snavs. Brug en tør klud til rengøring.
- Rengøring af ventilator: Ensure the cooling fan and vents are not obstructed. Clean them regularly to maintain optimal cooling performance.
- Batteriets sundhed: Overvåg batteri voltage and health regularly. Ensure the battery type setting in the controller matches your battery.
9. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Controlleren tænder ikke | Batteri ikke tilsluttet eller lav spændingtage; incorrect wiring. | Ensure battery is connected first with correct polarity and has sufficient voltage. Check all connections. |
| Ingen opladning fra solpaneler | Solar panels not connected; insufficient sunlight; PV voltage too low/high; incorrect PV wiring. | Check PV connections and polarity. Ensure adequate sunlight. Verify PV voltage er inden for regulatorens driftsområde. |
| Batteriet oplades ikke helt | Incorrect battery type setting; undersized solar array; faulty battery. | Verify battery type setting. Ensure solar array size is adequate for your battery capacity and load. Test battery health. |
| Indlæsningen virker ikke | Load not connected; load mode incorrect; battery low voltage afbryde forbindelsen. | Check load connections. Adjust load mode settings. Ensure battery voltage er over den lave voltage disconnect threshold. |
10. Brugertips
- Panel Sizing: When connecting multiple solar panels, ensure their combined voltage and power output remain within the controller's specified limits (e.g., Max Open Voltage of PV Module and Max. Input Power). For example, if using 160W panels, calculate the total wattage og bindtage to match your controller model.
- Batterikompatibilitet: Always double-check that the selected battery type in the controller's settings accurately reflects the type of battery you are using (e.g., LiFePO4, Lead-Acid, Gel). Incorrect settings can lead to inefficient charging or battery damage.
- Systemovervågning: Regularly check the LCD display for current charging status, battery voltage, and load status to ensure your system is operating optimally.
- Ventilation: Ensure the controller is installed in a location with good airflow to prevent overheating, especially for higher amperage modeller.
11. Garanti og support
PowMr products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your authorized PowMr dealer or the manufacturer directly. Keep your purchase receipt as proof of purchase.