Coolmay CX3G

Coolmay CX3G Series Programmable Logic Controller Instruction Manual

Model: CX3G | Brand: Coolmay

1. Introduktion

The Coolmay CX3G Series Programmable Logic Controller (PLC) is a highly integrated industrial control device designed for automation applications. It offers robust performance, high stability, and compatibility with Mitsubishi FX3U, FX2U, and FX3S series PLCs. This manual provides essential information for the proper installation, operation, and maintenance of your CX3G PLC.

Coolmay CX3G Series PLC front view

Figure 1: Coolmay CX3G Series PLC

Nøglefunktioner:

  • High integration for efficient industrial control.
  • Equipped with two PLC programming ports: Mini Type B USB for faster downloading and an RS232 (8-hole mouse head holder) port.
  • Supports multi-channel high-speed counting and high-speed pulse outputs.
  • Advanced security features with special 8-bit password encryption to prevent data reading.
  • Large program capacity of 32K steps and 32K power-failed holding registers.
  • Supports interrupting, linear arc interpolation, and PID auto-tuning.
  • Designed for easy wiring with 5.0mm pitch pluggable terminals and flexible installation using DIN rail (35mm wide) or mounting holes.
  • Compatible with Mitsubishi FX3U/FX2U/FX3S series PLCs and supports WORKS2 software.
  • Customizable analog input/output options, Ethernet, and RS485 communication.

2. Opsætning

2.1 Fysisk installation

The CX3G PLC is designed for easy installation in industrial environments. It can be mounted using a 35mm wide DIN rail or secured with mounting holes. Ensure adequate space for ventilation and wiring.

2.2 Komponentidentifikation

Refer to the diagram below for identification of the PLC's components and ports.

Coolmay CX3G Product Structure Diagram

Figure 2: Product Structure Diagram (Diagram 2 from seller description)

  1. Monteringshul
  2. Terminal block for input signal of power supply
  3. Klemmeblok for digital udgang
  4. LED of Digital Input
  5. LED of Digital Output
  6. PWR: Power-up State (RUN: The light is On when the PLC is run)
  7. ERR: The indicator will flash when the program is wrong
  8. RS485/RS232/CAN (default RS485, can change to RS232 or RS485 or CAN)
  9. RS485
  10. RUN/STOP PLC operational switch
  11. Analog indgang
  12. Analog udgang
  13. RS232
  14. DIN-Rail Slot (35mm)
  15. Klemmeblok for digital indgang
  16. PLC USB programmeringsport

Note: CAN port location refers to Diagram 3 Hardware interface drawing and Diagram 5 Com port optional (not provided in current images, but mentioned in text).

2.3 Ledningsinstruktioner

All series terminals are pluggable and designed for 22-14AWG wire. Ensure proper polarity and secure connections for all power and signal lines.

2.3.1 Strømforsyning

  • Input bindtage: DC24V

2.3.2 Digitale indgange

  • Isolation Mode: Photocoupling
  • Input Impedance: High-speed input 3.3KΩ, Common input 4.3KΩ
  • Input ON: Electric current of high-speed input is higher than 0.8mA/24V. Electric current of common input is higher than 0.95mA/24V.
  • Input OFF: Electric current of high-speed input is higher than 4mA/17V. Electric current of common input is higher than 4mA/17V.
  • Filter Function: With filter function, the filter time can be set among 0-60ms, defaulted as 10ms.
  • High-speed Counting: Normally single phase 6 channels 60KHz or AB(Z) phase 2 channels 30KHz+AB phase 1 channel 5KHz.
  • Vol: Passive NPN, Common isolation, S/S connect, 24V+.

2.3.3 Digital Outputs (Relay Type)

  • Max Current: 2A/point, 5A/8 point COM.
  • Indlæs Voltage: Below DC30V, Below AC220V.
  • Circuit Insulation: Relay/Mechanical insulation.
  • On Respond Time: About 10ms.
  • Mechanical Life (without load): 10 million times.
  • Electrical Life (rated load): 300 thousand times.
  • Vol: Normally open dry contact, output COM can be connected to positive or negative.

2.3.4 Digital Outputs (Transistor Type)

  • Max Current: MT: 0.5A/point, 0.8A/4point COM, 1.6A/8point COM; MOS tube.
  • Indlæs Voltage: DC24V.
  • Circuit Insulation: Optocoupler insulation.
  • Isolation Voltage: 1500VAC.
  • On Respond Time: High-speed output: 10µs, and others 0.5ms.
  • High-speed Output Frequency: 8 channels: Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting and pulse can't over 480KHz. CX3G-16MT, normally 8 channels 10KHz.
  • Vol: Low level NPN, COM connected to negative.

2.3.5 analoge indgange

The CX3G PLC supports various analog input types. For custom configurations, please contact customer service.

  • Input Signal: PT100/PT1000/Thermocouple NTC/0-10V/0-5V/-5V-5V/-10V-10V/0-20mA/4-20mA/others customizations.
  • Respond Time: One scanning cycle.
  • AI Quantity: 0-8 channels (optional).
  • Accuracy: 12bits.

2.3.6 analoge udgange

The CX3G PLC supports various analog output types. For custom configurations, please contact customer service.

  • Output Signal: 0-5V/0-10V/-10V-10V/-5V-5V/0-20mA/4-20mA/others can be customized.
  • AO Quantity: 0-8 channels (optional).
  • Accuracy: 12bits.

2.3.7 Kommunikationsporte

The PLC comes with two programming ports and supports various communication protocols.

Coolmay CX3G Electrical Parameters Table

Figure 3: Electrical Parameters Table (Diagram 1 from seller description)

  • Programmeringsport: Mini Type B USB port (for faster downloading) and RS232 (8-hole mouse head holder).
  • COM port definition:
    Coolmay CX3G PLC Programming and COM Port Pin Definitions

    Figure 4: PLC Programming and COM Port Pin Definitions (Diagram 4 & 5 from seller description)

    • Serial 1: RS232 (PLC programming port): Supports Mitsubishi programming port protocol, used for downloading PLC software and communicating with Mitsubishi programming devices.
    • Serial 2: RS485 (AB port): Supports Mitsubishi programming port protocol, Mitsubishi BD board protocol, RS protocol, and MODBUS RTU protocol. Supports RS2, WR3A, RD3A, ADPRW instructions.
    • Serial 3: RS485 (A1 B1): Supports Mitsubishi programming port protocol, RS2 protocol, and MODBUS RTU protocol. Supports RS2, WR3A, RD3A, ADPRW instructions.
    • CAN port: Supports RS2 and MODBUS RTU protocol. Supports RS2, WR3A, RD3A, ADPRW instructions.
    • Net communication: Supports Modbus TCP/UDP instruction. Supports WR3A, RD3A, ADPRW instructions.

2.4 Softwareinstallation

The Coolmay CX3G PLC is compatible with WORKS2 programming software. Please refer to the official Coolmay website for software downloads and installation guides. A download link for the user manual and related files is provided below:

Download User Manual and Related Files

Figure 5: Link to User Manual and Related File Downloads

3. Betjeningsvejledning

3.1 Power-Up and Status Indicators

  • PWR (Power-up State): The LED will be ON when the PLC is running correctly.
  • ERR (Error Indicator): This LED will flash if there is an error in the loaded program.

3.2 RUN/STOP Switch

The PLC features a physical RUN/STOP switch (labeled as item 10 in Figure 2) to control the operational state of the PLC program.

3.3 Programming and Data Transfer

Programs can be downloaded to the PLC via the Mini Type B USB port or the RS232 port. Ensure the correct programming software (e.g., WORKS2) is installed and configured on your computer.

3.4 Adgangskodebeskyttelse

The CX3G PLC supports special encryption to protect your program data. By setting an 8-bit password (e.g., "12345678"), you can prevent unauthorized reading of the data. Note that only 8-bit password encryption is supported.

Coolmay CX3G PLC with password protection feature

Figure 6: Password Protection Feature

4. Vedligeholdelse

To ensure the longevity and reliable operation of your Coolmay CX3G PLC, follow these general maintenance guidelines:

  • Rensning: Regularly clean the exterior of the PLC with a soft, dry cloth. Avoid using harsh chemicals or solvents.
  • Miljøkontrol: Ensure the operating environment adheres to the specified temperature and humidity ranges (see Specifications). Protect the unit from excessive dust, moisture, and corrosive gases.
  • Tilslutningskontrol: Periodically inspect all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or failure.
  • Firmware opdateringer: Check the official Coolmay webwebstedet for tilgængelige firmwareopdateringer, der kan forbedre ydeevnen eller løse kendte problemer.

5. Fejlfinding

This section provides solutions to common issues you might encounter with your CX3G PLC.

5.1 Indikatorlys

  • ERR LED Flashing: This indicates an error in the loaded program. Review your PLC program for logical errors, syntax issues, or incorrect configurations.
  • PWR LED Off: Check the DC24V power supply connection and ensure it is providing the correct voltage. Verify that the power source is active.

5.2 Communication Issues

  • Unable to Connect via USB/RS232:
    • Ensure the correct drivers are installed for the programming cable.
    • Verify the communication settings (baud rate, parity, data bits, stop bits) in your programming software match the PLC's settings.
    • Check the physical cable connection for damage or looseness.
    • Confirm the PLC is powered on.
  • Data Read Protection: If you cannot read data from the PLC, it might be protected by an 8-bit password. Ensure you have the correct password to access the program.

5.3 Program Execution Problems

  • Program Not Running: Ensure the RUN/STOP switch is in the RUN position. Check for any program errors indicated by the ERR LED.
  • Uventet opførsel: Vedrview your program logic carefully. Ensure all inputs and outputs are correctly mapped and configured.

6. Specifikationer

The following table details the general and electrical specifications for the Coolmay CX3G Series PLC.

Coolmay CX3G Product Naming Rules and Basic Specification Table

Figure 7: Product Naming Rules and Basic Specification Table (Diagram 1 from seller description)

Generelle specifikationer:

  • Programkapacitet: 32K steps
  • Slukningsfastholdelse: 32K registers
  • CPU: Military grade 32-bit chip with fast running speed and strong anti-interference ability. Input and output are isolated by optocouplers.
  • Programming Software Compatibility: WORKS2
  • Installation: 5.0mm pitch pluggable terminals, DIN rail (35mm wide) and mounting holes.

Miljøspecifikationer:

  • Driftstemperatur: 0°C til 50°C
  • Relativ luftfugtighed: 5% to 95% RH (non-condensing)
  • Opbevaringstemperatur: -20°C til 70°C
  • Vibrational Frequency: 10-57Hz, amplitude 0.035mm; 57Hz-150Hz, 4.9m/s² (10 times each on X, Y, Z axes, total 80 minutes each).

Model Specifics (Examplæs):

ModelDigital I/OAnalog I/O (Optional)COM-portStørrelse (MM)Cutout Size (MM)
CX3G-16M8DI/8DO02 RS485 port are default can be customized66*90*3657*90
CX3G-24M12DI/12DO61 RS485, 1 RS232, 1 CAN, Ethernet port is optional in 48M130*90*36122*90
CX3G-32M16DI/16DO21 RS485, 1 RS232, 1 CAN, Ethernet port is optional in 48M130*90*36122*90
CX3G-48M24DI/24DO82 RS485 are default can be customized200*90*36192*90
CX3G-64M32DI/32DO81 RS485, 1 RS232, 1 CAN, Ethernet port is optional in 48M290*90*36282*90
CX3G-80M40DI/40DO4CAN is optional290*90*36282*90

Note: MT indicates a transistor output (Y0-Y3 is MOS tube, others are transistors); MR indicates a relay output; MRT is a mixed output. CX3G-24M with customized 8 analog inputs will have a maximum digital input of 10.

7. Brugertips

  • Analog I/O Customization: When ordering, ensure you select the host unit together with any desired analog input/output options. Analog I/O cannot be shipped separately as they require factory processing and welding with the host. If analog quantities are purchased separately without a host, a download line will be sent by default.
  • Programmering Software: For programming the CX3G PLC, you will need compatible software such as WORKS2. This software is typically available for download from the official Coolmay webwebsted.
  • Tekniske forespørgsler: If you have specific technical questions, need recommendations for models, or require assistance with customization, do not hesitate to contact Coolmay customer service. They aim to answer questions within 24 hours.

8. Garanti og support

Coolmay is committed to providing high-quality products and excellent customer service. All products are brand new and undergo rigorous quality checks.

8.1 Kundesupport

For any questions, technical assistance, or inquiries regarding your Coolmay CX3G PLC, please contact Coolmay customer service. They strive to respond to all inquiries within 24 hours.

8.2 Documentation and Downloads

The latest user manuals, programming software, and related files can be downloaded from the official Coolmay website. Please refer to the download link provided in Section 2.4 for access to these resources.

Relaterede dokumenter - CX3G

Preview Coolmay PLC Programmeringsmanual V20.81 - Instruktioner og betjening
Omfattende programmeringsmanual til Coolmay PLC-seriens styreenheder (V20.81), der detaljerer instruktioner, enhedsbetjening og programmeringsprincipper. Kompatibel med Mitsubishi-software.
Preview Coolmay L02-seriens PLC-programmeringsmanual: Funktioner, specifikationer og anvendelser
Udforsk programmeringsmanualen til Coolmay L02-serien af ​​PLC'er. Denne vejledning beskriver L02 PLC'ens avancerede funktioner, systemarkitektur, modulkompatibilitet, kommunikationsprotokoller (Modbus, Ethernet/IP) og programmeringsinstruktioner. Ideel til industriel automatisering og kontrolapplikationer.
Preview Coolmay Cloud Platform brugervejledning: Registrering, binding og konfiguration
En omfattende guide til brug af Coolmay Cloud-platformen til fjernbetjent PLC-drift, der dækker kontoregistrering, enhedsbinding, konfiguration af slavevariabler og opsætning af netværksparametre. Dette dokument beskriver trinene til integration af Coolmay PLC'er med skyen for forbedret overvågning og kontrol.
Preview Coolmay QM3G-seriens HMI/PLC All-in-One programmeringsmanual: Funktioner, specifikationer og betjeningsvejledning
Denne omfattende programmeringsmanual beskriver detaljeret Coolmay QM3G-serien af ​​HMI/PLC All-in-one-enheder. Den dækker hardwarespecifikationer, programmeringsforholdsregler, PLC- og HMI-funktioner, kommunikationsprotokoller (Modbus, RS485, CAN, Ethernet) og softwarebrug, og giver vigtige oplysninger til ingeniører og teknikere, der arbejder med Coolmays industrielle automationsløsninger.
Preview Coolmay LO2S Series PLC User Manual - Features, Specifications, and Wiring
Comprehensive user manual for the Coolmay LO2S Series Programmable Controller (PLC). Details features, technical parameters, product structure, electrical diagrams, wiring instructions, and troubleshooting tips for industrial automation.
Preview Coolmay TK6043BH 4.3" industrielt HMI - Funktioner, specifikationer og brugermanual
Detaljeret information om Coolmay TK6043BH 4.3-tommer HMI, herunder produktfunktioner, tekniske specifikationer, oversigtsmål, terminaldefinitioner og brugervejledning til installation.