1.Overview
The Neoteck NTK098 is a pocket-sized 3 9/10-bit automatic digital multimeter, offering stable performance, high precision, high reliability, clear readings, and overload protection. Powered by 2 x AAA 1.5V batteries, it features a large-screen LCD display with a bright backlight, ensuring readability even in low light or with low battery. This instrument is designed for measuring DC/AC voltage, DC/AC current, resistance, capacitance, diode, continuity, frequency, and true RMS values. It is an ideal tool for laboratories, factories, radio enthusiasts, and general household electrical testing. The included Banana Plug to Alligator Clip Test Lead cables are useful for quickly assembling and testing circuits.

Image: Neoteck Digital Multimeter NTK098 with included test leads and alligator clips.
2. Nøglefunktioner
- True RMS measurement for accurate readings of non-sinusoidal waveforms.
- NCV (Non-Contact Voltage) function for safe voltage afsløring.
- Auto Range for simplified operation.
- 9999 Counts display for high resolution.
- Black EBTN screen for enhanced readability in various lighting conditions.
- Main measurements: DC/AC Voltage, DC/AC Current, Resistance, Continuity, Diode, Capacitance, Frequency, Temperature.
- Integrated Flashlight for working in dark areas.
- Backlight for clear display visibility.
- Data Hold function to freeze readings.
- Auto Power Off to conserve battery life.
- Full unit symbol display.
- Max/Min function to record extreme values.
- Relativ værdimåling.
3. Pakkens indhold
Tjek venligst pakken for følgende varer:
- 1 x Neoteck 9999 Counts Digital Multimeter (NTK098)
- 1 x Test Leads (1 pair, red and black)
- 1 x Test Leads Banana Plug to Alligator Clip (1 pair, red and black)
- 1 x Brugermanual

Image: The complete package contents of the Neoteck Digital Multimeter NTK098.
4. Opsætning
4.1 Batteriinstallation
The multimeter is powered by 2 x AAA 1.5V batteries. To install or replace batteries:
- Sørg for, at multimeteret er slukket, og at alle testledninger er frakoblet.
- Find batteridækslet på bagsiden af enheden.
- Skru fastholdelsesskruen(e) af, og fjern dækslet.
- Insert the 2 x AAA 1.5V batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Sæt dækslet til batterirummet på igen, og fastgør det med skruen/skruerne.
Enheden har lav lydstyrketage display indicator to alert you when batteries need replacement.
4.2 Tilslutning af testledninger
For de fleste målinger (volumentage, resistance, capacitance, frequency, temperature, diode, continuity), insert the red test lead into the 'VΩHz' jack and the black test lead into the 'COM' (common) jack. For current measurements up to 10A, insert the red test lead into the '10A' jack and the black test lead into the 'COM' jack.
5. Betjeningsvejledning
Turn the rotary switch to the desired measurement function. The multimeter features auto-ranging for most functions, simplifying operation.
5.1 DC/AC Voltage Måling
Select 'V~' for AC voltage eller 'V=' for DC-volumentage. Tilslut testledningerne parallelt til det kredsløb eller den komponent, du ønsker at måle.
5.2 DC/AC Current Measurement
Select 'A~' for AC current or 'A=' for DC current. Connect the test leads in series with the circuit. For currents up to 10A, use the '10A' jack for the red lead. Ensure the circuit is de-energized before connecting the multimeter in series.
5.3 Modstandsmåling
Select 'Ω'. Connect the test leads across the component to measure its resistance.
5.4 Kapacitansmåling
Select 'F'. Connect the test leads across the capacitor to measure its capacitance. Ensure the capacitor is discharged before testing.
5.5 Frekvensmåling
Select 'Hz'. Connect the test leads to the signal source to measure its frequency.
5.6 Temperaturmåling
Select 'TEMP'. Connect the temperature probe to the appropriate jacks (usually 'VΩHz' and 'COM'). Place the probe in contact with the object whose temperature you wish to measure.

Image: The multimeter measuring temperature using a probe immersed in water.
5.7 NCV-funktion (kontaktfri volumen)tage)
Rotate the dial to 'NCV'. Hold the top part of the multimeter near an AC voltage source (e.g., an electrical outlet or live wire). The display will show flickering lines (1 short line for low voltage, 4 short lines for high voltage) and an alarm will sound if AC voltage er opdaget.

Image: The NCV function in use, detecting voltage from an electrical outlet.
5.8 Kontinuitetstest
Select 'Ω' and press the 'SELECT' button to cycle through functions until the continuity symbol (a speaker icon) is displayed. Connect the test leads across the circuit or component. An alarm will sound if the resistance is less than 50Ω, indicating continuity.

Image: The multimeter performing a continuity test, indicated by a buzzing sound.
5.9 Diodetest
Select 'Ω' and press the 'SELECT' button to cycle through functions until the diode symbol is displayed. Connect the test leads across the diode to test its forward voltage drop.
5.10 Datahold
Press the 'HOLD' button to freeze the current reading on the display. Press it again to release the hold function.
5.11 Lommelygte og baggrundsbelysning
Press the backlight button (often labeled with a light bulb icon or combined with 'HOLD') to activate the flashlight and display backlight. The backlight automatically turns off after 15 seconds to save power.

Image: The multimeter's flashlight feature in use, providing illumination in a dark area.

Image: A comparison showing the superior readability of the large inverted black EBTN display compared to a common backlight.
5.12 Max/Min funktion
Press the 'MAX/MIN' button to enter Max/Min recording mode. The multimeter will continuously record the maximum and minimum values detected. Press again to cycle between MAX, MIN, and current readings.
5.13 Relative Value Measurement
Press the 'RELA' button to enter relative measurement mode. This function subtracts the current reading from subsequent readings, showing the difference.
5.14 Automatisk slukning
The multimeter will automatically power off after approximately 15 minutes of inactivity to conserve battery life. To disable this feature temporarily, refer to the full user manual (if provided) or specific product documentation.
6. Specifikationer
| Feature | Specifikation |
|---|---|
| Vise | Black EBTN screen, 9999 (3 9/10) bits automatic polarity display |
| Målemetode | Dobbelt integreret A/D-konvertering |
| Sampling Rate | Cirka 3 gange i sekundet |
| Overrækkende display | "0L" |
| Lav voltage Display | Ja |
| Arbejdsmiljø | 0~40℃, relative humidity < 80% |
| Strømforsyning | 2 x AAA 1.5V battery (included) |
| Dimensioner (L×B×H) | 142×70×32 mm |
| DC bindtage Range & Accuracy | 999.9mV/9.999V/99.99V ±(0.5%+3); 999.9V ±(0.8%+10) |
| AC Voltage Range & Accuracy | 0.999V/9.999V/99.99V ±(0.8%+3); 999.9V ±(1.0%+5) |
| DC Current Range & Accuracy | 100mA/10A ±(1.2%+10) |
| AC Current Range & Accuracy | 100mA/10A ±(1.2%+10) |
| Resistance Range & Accuracy | 999.9Ω/9.999kΩ/99.99kΩ/999.9kΩ/9.999MΩ ±(0.8%+3); 99.99MΩ ±(2.5%+3) |
| Kapacitansområde og nøjagtighed | 9.999nF/99.99nF/999.9nF/9.999μF/99.99μF/999.9μF/9.999mF ±(3.5%+20); 99.99mF ±(5.0%+3) |
| Frequency Range & Accuracy | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz ±(0.1%+3) |
| Temperaturområde | -20℃ til 1000℃ / -4℉ til 1832℉ |
| Auto/manuel rækkevidde | Ja |
| Ægte RMS | Ja |
| AC Voltage Båndbredde | 40Hz - 1kHz |
| Kontinuitetstest | Alarm beep sounds if resistance < 50Ω |
| Datahold | Ja |
| Lommelygte | Ja |
| Diodetest | Yes (0.15V-3V) |
| NCV | Alarm beep sounds and LED blink if AC voltage opdaget |
| Overbelastningsbeskyttelse | Ja |
| Kortslutningsbeskyttelse | Ja |
| Alligator Clip Cable Wire Dia | 3.5mm/0.14" |
| Male Banana Plug Pin Dia | 4mm/0.16" |
| Alligator Clip Open Width (Max.) | 9mm/0.75" |
| Banana Outer Size (L*D) | 5.1 x 1cm/2" x 0.4" |
| Alligator Clip Size (L*W*T) | 5.1 x 2 x 0.8cm/2" x 0.8" x 0.31" |
| Total Length (Alligator Clip Cable) | 80 cm / 2.62 fod |
| Rated Current (Alligator Clip Cable) | 15A |
| MAX Voltage (Alligator Clip Cable) | 1000V |
| Color (Alligator Clip Cable) | Rød, sort |
| Material (Alligator Clip Cable) | Metal, Plast |
| Total Weight (Alligator Clip Cable) | 75 g |
7. Vedligeholdelse
7.1 Rengøring
Tør multimeteret c afasing with a dry, soft cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the plastic or electronic components.
7.2 Udskiftning af batteri
When the low battery indicator appears on the display, replace the 2 x AAA 1.5V batteries promptly. Always ensure the device is turned off and all test leads are disconnected before opening the battery compartment. Dispose of old batteries responsibly according to local regulations.
7.3 Opbevaring
Store the multimeter in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. If storing for an extended period, it is advisable to remove the batteries to prevent leakage.
8. Fejlfinding
- Ingen skærm/strøm: Check if the batteries are correctly installed and charged. Replace the 2 x AAA 1.5V batteries if the low voltage indicator is present or if the device does not power on.
- Forkerte aflæsninger: Ensure that the test leads are securely connected to the correct input jacks for the desired measurement. Verify that the rotary switch is set to the appropriate function and range. Inspect test leads for any damage or breaks.
- Ingen biplyd ved kontinuitet: Confirm that the continuity function is selected (speaker icon). If the resistance of the circuit or component is above 50Ω, the beep will not sound.
- NCV registrerer ikke volumentage: Ensure the NCV function is selected. Hold the multimeter's NCV sensor (usually at the top) close enough to the AC voltage kilde.
- Display Shows "OL": This indicates an over-range condition. The measured value exceeds the maximum range of the selected function. Try switching to a higher range if available, or ensure the measurement is within the device's capabilities.
9. Brugertips
- For accurate temperature readings, ensure the temperature probe is properly connected and in good contact with the object being measured. Allow a few moments for the reading to stabilize.
- Utilize the built-in flashlight feature in dimly lit environments for better visibility of test points and to ensure safe and accurate probe placement.
- While the multimeter has an auto-power-off feature, manually turning off the device when not in use can further conserve battery life, especially during short breaks.
- Start altid med det højeste område, når du måler et ukendt volumen.tage or current to prevent damage to the multimeter, then adjust downwards if necessary.
10. Garanti og support
For warranty information, technical support, or service inquiries regarding your Neoteck Digital Multimeter NTK098, please refer to the contact details provided with your purchase documentation or visit the official Neoteck webwebsted. Gem din købsbevis til garantikrav.