1. Introduktion
The SINOTIMER TM919B is a robust 30A programmable digital timer switch designed for automatic control of various electrical equipment. This DIN rail-mounted device offers 7-day, 24-hour programming capabilities, allowing users to set up to 16 distinct ON/OFF programs daily or weekly. It is an ideal solution for managing the operation of street lamps, neon lights, signs, general lighting, water heaters, air conditioners, billboards, rice cookers, superchargers, sprayers, bottling machines, preheaters, agricultural facilities, and broadcasting equipment. The timer switch incorporates a 1.2V/40mA rechargeable battery to retain programmed settings during power outages, ensuring reliable operation. Key features include low power consumption, a high-precision CMOS chip, strong anti-interference capabilities, and a user-friendly setup process.
2. Sikkerhedsoplysninger
- Always disconnect power at the main circuit breaker before attempting any installation, wiring, or maintenance.
- Installation should be performed by a qualified electrician or an individual with a thorough understanding of electrical systems.
- Ensure all wiring adheres to local and national electrical codes and regulations.
- Do not exceed the maximum load rating of 30A for the timer switch. Overloading can cause damage to the device and create a fire hazard.
- Hold enheden væk fra vand, fugt og ekstreme temperaturer.
- Forsøg ikke at åbne eller reparere enheden selv. Overlad al service til kvalificeret personale.
3. Pakkens indhold
- 1 x SINOTIMER TM919B Digital Timer Switch
- 1 x brugermanual
4. Produktet er slutview og kontroller
Familiarize yourself with the components and controls of your TM919B timer switch:

Kontrolknapper:
- P (Program): Enters program setting mode. Press repeatedly to cycle through ON/OFF settings.
- D+ (Dag): Adjusts the day of the week or program day.
- H+ (Time): Adjusts the hour for current time or program time.
- M+ (Minut): Adjusts the minute for current time or program time.
- NULSTIL: Rydder alle indstillinger og nulstiller timeren til fabriksindstillingerne.
- MANUEL: Skifter mellem ON-, AUTO- og OFF-tilstande.
Displayindikatorer:
- Th: Indicates Thursday (example, will show current day).
- AM/PM: Time format indicator.
- ON/AUTO/OFF: Current operating mode.
- ON (Red LED): Indicates the timer output is currently ON.
5. Specifikationer
| Feature | Specifikation |
|---|---|
| Model | TM919B |
| Strømforsyning | AC220V, 50/60Hz |
| Belastningskapacitet | 30A (modstandsdygtig belastning) |
| Skift kontakt | 1 Change-over Switch |
| Programmerbare begivenheder | 16 ON/OFF programs per day or week |
| Minimum interval | 1 minut |
| Timing Range | 1 minute to 168 hours (7 days) |
| Internt batteri | 1.2V/40mA rechargeable (for program retention) |
| Nøjagtighed | ≤1s/24h at 25°C |
| Materiale | ABS + elektroniske komponenter |
| Farve | Hvid |
Dimensioner:

- Front View: 3.5cm (width) x 8.7cm (height)
- Side View: 6.5cm (depth) x 4.7cm (top width) x 4.5cm (main body height) x 3cm (DIN rail clip height)
6. Installation
The TM919B timer switch is designed for DIN rail mounting. Ensure the DIN rail is securely installed in a suitable enclosure.
Ledningsdiagram:
Refer to the diagram below for proper wiring. Always ensure power is disconnected before making any electrical connections.

- Strømindgang: Connect the Live (L) wire to terminal 1 and the Neutral (N) wire to terminal 2. The timer requires AC220V power.
- Udgangsforbindelser: The timer has a single change-over switch output.
- Terminal 4: Common (COM) output.
- Terminal 3: Normally Open (NO) contact. This contact closes when the timer is ON.
- Terminal 5: Normally Closed (NC) contact. This contact opens when the timer is ON.
- Belastningsforbindelse: For loads up to 30A, you can directly connect your appliance to the appropriate output terminals (e.g., L to terminal 4, appliance to terminal 3, and appliance to N). For higher inductive loads or loads exceeding 30A, it is highly recommended to use an external contactor (as shown in Figure 3) to protect the timer's internal relay.
7. Opsætning og programmering
7.1 Initial Setup / Reset
- Upon first power-up or after a long period of no power, the display may be blank. The internal battery will charge once power is applied.
- Tryk på NULSTIL button (usually a small recessed button, use a pointed object like a pen tip) to clear all previous settings and reset the timer. The display will show "0:00" and "AUTO".
7.2 Indstilling af aktuel tid
- Tryk på D+ knappen for at indstille den aktuelle ugedag.
- Tryk på H+ knappen for at indstille den aktuelle time.
- Tryk på M+ knappen for at indstille det aktuelle minut.
- Tiden gemmes automatisk efter et par sekunders inaktivitet.
7.3 Programmering af tænd/sluk-cyklusser
The TM919B allows for up to 16 ON and 16 OFF programs. Each program consists of a specific time and day(s) for the timer to switch ON or OFF.
- Tryk på P button once. The display will show "1 ON" (for the first ON program).
- Trykke D+ to select the day(s) for this program. Options include: every day, specific weekdays, weekends, etc.
- Trykke H+ to set the hour for the "1 ON" program.
- Trykke M+ to set the minute for the "1 ON" program.
- Trykke P again. The display will show "1 OFF" (for the first OFF program).
- Repeat steps 2-4 to set the day(s), hour, and minute for the "1 OFF" program.
- Fortsæt med at trykke P to cycle through "2 ON", "2 OFF", up to "16 ON", "16 OFF", setting each as needed.
- If you don't need all 16 programs, simply stop pressing P after setting your desired programs. The timer will exit programming mode after about 10 seconds of inactivity.
- To exit programming mode at any time, press the MANUEL knap.
8. Betjeningsvejledning
Once programmed, the timer will operate automatically according to your settings. The current operating mode is displayed on the LCD screen (ON, AUTO, or OFF).
Manuel tilsidesættelse:
De MANUEL button allows you to temporarily override the programmed schedule without deleting it. Pressing the MANUEL button cycles through the following modes:
- PÅ: The output is forced ON, regardless of the program.
- BIL: The timer operates according to the programmed schedule.
- OFF: The output is forced OFF, regardless of the program.
To return to automatic operation, press the MANUEL knappen, indtil "AUTO" vises.
9. Vedligeholdelse
- Keep the timer switch clean and dry. Use a soft, dry cloth to wipe the exterior.
- Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Sørg for korrekt ventilation omkring enheden for at forhindre overophedning.
- The internal rechargeable battery is designed for long-term use and typically does not require replacement during the product's lifespan.
- There are no user-serviceable parts inside the unit. Any unauthorized opening or modification will void the warranty.
10. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Skærmen er tom eller svag. | No power supply or internal battery discharged. | Check power connections. If power is present, allow time for the internal battery to charge (up to 4 hours). |
| Timer is not switching ON/OFF as programmed. | Incorrect program settings, manual override engaged, or incorrect current time. | Verify all ON/OFF programs are set correctly. Ensure the timer is in "AUTO" mode (press MANUAL button until "AUTO" is displayed). Check that the current day and time are set accurately. |
| Udgangen er altid ON eller altid OFF. | Manuel overstyring aktiveret. | Tryk på MANUEL button until "AUTO" is displayed on the screen. |
| Appliance connected to timer is not working. | Appliance fault, incorrect wiring, or timer output not active. | Test the appliance directly. Verify wiring connections (refer to Section 6). Check timer mode and program. Ensure the load does not exceed 30A. |
11. Brugertips
- For Inductive Loads: If connecting motors, fans, or other inductive loads, consider using an external contactor. This will protect the timer's internal relay from high inrush currents and extend its lifespan.
- Bekræft ledninger: Always double-check your wiring connections against the provided diagram before applying power to prevent damage to the timer or connected appliances.
- Testprogrammer: After programming, use the MANUEL button to cycle the output ON and OFF to quickly verify your wiring and ensure the connected appliance responds as expected, without waiting for the scheduled time.
- Power Outage Beskyttelse: The built-in rechargeable battery ensures your programs are retained during power outages. However, for extended outages, the battery may discharge, requiring you to reset the time.
12. Garanti og support
For technical assistance, warranty claims, or product support, please contact your original retailer or the manufacturer directly. Please have your product model number (TM919B) and proof of purchase readily available when seeking support.