This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Maxpeedingrods MXR4500i Portable Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.

Sikkerhedsoplysninger
ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i alvorlig personskade eller død.

FARE: Kuliltefare
- Brug af en generator indendørs KAN DRÆBE DIG PÅ MINUTTER. Generatorens udstødning indeholder kulilte. Dette er en gift, du ikke kan se eller lugte.
- Brug ALDRIG i et hjem eller garage, SELVOM døre og vinduer er åbne.
- Brug kun UDENFOR og langt væk fra vinduer, døre og ventilationsåbninger.
- Undgå andre generatorfarer. LÆS MANUALEN FØR BRUG.
WARNING: Electrical Shock and Fire Hazard
- Generator producerer kraftig voltage that can cause death or great physical harm.
- When using the generator for back-up power, notify the utility company.
- Use approved transfer equipment to isolate the generator from the electric utility.
- NEVER connect to a building's electrical system unless a transfer switch has been installed by a qualified electrician.
- NEVER touch bare wires or receptacles.
- NEVER use the generator with electrical cords that are worn, frayed, bare, or otherwise damaged.
- NEVER operate the generator in rain or snow, or when the generator is set on a wet surface.
Pakkens indhold
Ved udpakning skal du kontrollere, at alle nedenstående varer er til stede og ubeskadigede:

- Maxpeedingrods MXR4500i Inverter Generator Unit
- Olietragt
- Tændrørnøgle
- Skruetrækker
- Forlængelsesbjælke
- Two types of power plugs (e.g., EU type)
- Generatordæksel
- Brugervejledning (dette dokument)
Produkt overview
Familiarize yourself with the components and control panel of your MXR4500i generator.
Kontrolpanel

| Komponent | Funktion/beskrivelse |
|---|---|
| ENG.SW (Engine Switch) | Controls the engine's power (ON/OFF). |
| Indikatorlys | Includes Output, Overload, and Low Oil indicators. |
| V.F.T Meter | Digital display for Voltage, Frequency, and Running Time. |
| AC nulstilling | Resets the AC circuit in case of an overload trip. |
| DC Breaker | Protects the DC circuit from overload. |
| DC 12V 8.3A Outlet | Provides 12V DC power for charging batteries or other DC devices. |
| Two 230V 16A Outlets | Standard AC power outlets for connecting appliances. |
| Jordingsmøtrik | Point for connecting a ground wire for safety. |
Indikatorlys betydninger

- Digital måler: Viser voltage, frequency, cumulative running time, and single running time.
- Overload Indicator Light (Red): Flashes when the generator is overloaded. The overload protection will activate, cutting off power. Reduce the load and reset if necessary.
- Low Oil Indicator Light (Yellow): Flashes when the oil level is insufficient. Refill oil immediately to prevent engine damage.
- Ready Indicator Light (Green): Flashes when the generator is running and outputting power normally.
Opsætning
- Udpakning: Tag forsigtigt generatoren og alt tilbehør ud af emballagen. Undersøg for eventuelle forsendelsesskader.
- Placering: Place the generator on a firm, level surface OUTSIDE in a well-ventilated area, far from windows, doors, and vents. Ensure at least 3-5 feet of clear space around the generator.
- Tilsæt motorolie:
- Fjern oliepåfyldningsdækslet/målepinden.
- Using the provided funnel, slowly add the recommended engine oil (refer to Specifications for type and capacity) until it reaches the upper mark on the dipstick. Do not overfill.
- Sæt oliepåfyldningsdækslet/målepinden sikkert på igen.
- Tilføj brændstof:
- Ensure the engine is OFF and cool.
- Åbn brændstoftankens dæksel.
- Fill the fuel tank with fresh, unleaded gasoline. Do not overfill; leave some space for expansion.
- Sæt brændstoftankdækslet sikkert på igen.
- Jording: For safety, connect a ground wire from the grounding nut on the control panel to a suitable earth ground (e.g., a ground rod).
Betjeningsvejledning
Start af generatoren

- Ensure the generator is on a level surface and all safety precautions are observed.
- Drej brændstofventilen til ON position.
- Set the Engine Switch (ENG.SW) to the ON position.
- If starting a cold engine, pull the choke lever to the KVÆLE position. If the engine is hot, do not close the choke valve.
- Træk fast i håndtaget til rekylstarteren, indtil motoren starter.
- Once the engine starts, slowly push the choke lever back to the SLUKKET position.
- Allow the generator to run for a few minutes to warm up before connecting any electrical loads.
- Connect your appliances to the appropriate AC or DC outlets.
Stop af generatoren
- Afbryd alle elektriske belastninger fra generatorens stikkontakter.
- Set the Engine Switch (ENG.SW) to the SLUKKET position.
- Drej brændstofventilen til SLUKKET position.
Opretholdelse
Regular maintenance is crucial for the longevity and reliable performance of your generator.
- Motorolie: Check oil level before each use. Change oil after the first 20 hours of operation, then every 50-100 hours or annually, whichever comes first.
- Luftfilter: Inspect the air filter every 50 hours or more frequently in dusty conditions. Clean or replace as needed.
- Tændrør: Inspect the spark plug every 100 hours. Clean or replace if fouled or worn. Ensure proper gap.
- Brændstofsystem: If storing the generator for an extended period (more than 30 days), drain the fuel tank and carburetor, or use a fuel stabilizer.
- Generel rengøring: Keep the generator clean and free of debris. Ensure cooling vents are not obstructed.
Fejlfinding
Refer to this section for common issues and their solutions. If problems persist, contact technical support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Motoren vil ikke starte | No fuel, low oil, engine switch OFF, fuel valve OFF, choke incorrect. | Add fuel, add oil, turn engine switch ON, turn fuel valve ON, adjust choke. |
| Ingen strømudgang | Overload, AC breaker tripped, faulty connection. | Reduce load, press AC Reset button, check connections. |
| Overload indicator light on | Generatoren er overbelastet. | Disconnect some appliances to reduce the load. Press AC Reset. |
| Low oil indicator light on | Motoroliestanden er lav. | Stop the engine immediately and add recommended engine oil. |
Specifikationer

| Feature | Detalje |
|---|---|
| Modelnummer | MXR4500i |
| Mærkenavn | Maxpeedingrods |
| Motortype | 4-stroke 145cc OHV, Air-cooled |
| Nominel voltage | 220V |
| Nominel strøm | 13.9A |
| Frekvens | 50 Hz |
| Kører Watts | 3200W |
| Peak Watts | 3500W |
| Oliekapacitet | 750 ML |
| Dimensioner (L x B x H) | 43.5 cm x 37.5 cm x 45.5 cm |
| Certificering | EPA CARB, ISO 9001:2015, CE, EURO V |
Brugertips
To maximize the performance and lifespan of your generator:
- Always use fresh, high-quality unleaded gasoline. Stale fuel can cause starting issues and engine damage.
- Regularly check and maintain the engine oil level. Using the correct type and amount of oil is critical for engine health.
- Avoid running the generator continuously at maximum load for extended periods to prevent overheating and premature wear.
- When storing the generator, especially for more than a month, ensure the fuel system is properly prepared (drained or stabilized) to prevent carburetor issues.
Garanti og support

Garanti
Your Maxpeedingrods MXR4500i Inverter Generator comes with a 2 års garanti, ensuring brand guarantee and worry-free after-sales support. For specific warranty claims and details, please refer to the product manual's after-sales service section or contact the seller directly.
Certificeringer
This product is certified under:
- CE (MD & EMC directive)
- ISO 9001:2015
- EURO V certification
- EPA CORB
Teknisk support
Maxpeedingrods provides long-term professional technical services to address any concerns or issues you may encounter with your generator. Please contact the seller or manufacturer's support channels for assistance.