CEM DT-9935

CEM DT-9935 Digital LCR Meter

Professional Inductance, Capacitance, Resistance Tester

1. Introduktion

The CEM DT-9935 is a professional digital LCR meter designed for accurate and reliable measurement of inductance (L), capacitance (C), and resistance (R). Featuring an 11000-bit LCD display, series/parallel dual mode, and full-range protection, this meter is an essential tool for electronics enthusiasts, technicians, and engineers. It provides accurate, fast, and secure measurements for a wide range of electrical and electronic testing applications.

2. Nøglefunktioner

  • 11000-Bit LCD display for clear readings.
  • Series/parallel dual mode for versatile component analysis.
  • Full range protection ensures durability and safety.
  • Automatic identification of capacitance, inductance, and resistance frequency.
  • Accurate, fast, and secure measurement capabilities.
  • Sampling rate of 5 times per minute.
  • Overrange prompt: "OL" or "-OL".
  • Automatisk nedlukning efter 10 minutters inaktivitet for at spare batteri.
  • Complies with IEC61000EMC standard for security.
CEM DT-9935 LCR Meter with features highlighted
Figur 2.1: Forside view of the DT-9935 LCR Meter highlighting key features like the 11000-bit LCD display, series/parallel dual mode, and full range protection.

3. Pakkens indhold

Ved udpakning skal du kontrollere, at alle nedenstående varer er til stede og i god stand:

  • 1 x CEM DT-9935 Digital LCR Meter
  • 1 x Set of Test Leads (Red and Black)
  • 1 x Brugermanual (dette dokument)
DT-9935 LCR Meter in its packaging with test leads
Figure 3.1: The DT-9935 LCR Meter as packaged, including the meter and test leads.

4. Opsætning

4.1 Batteriinstallation

  1. Find batteridækslet på bagsiden af ​​måleren.
  2. Åbn dækslet ved at skubbe eller skrue det af.
  3. Insert four (4) 1.5V "AA" batteries (15A or IE CLR 6 type recommended), ensuring correct polarity as indicated inside the compartment.
  4. Luk batterirummets dæksel forsvarligt.

4.2 Tilslutning af testledninger

  1. Insert the red test lead into the positive ("+") input terminal.
  2. Insert the black test lead into the negative ("-") input terminal.
  3. For guarded measurements, connect the guard leads to the "GUARD" terminals to minimize stray capacitance and improve accuracy.

5. Betjeningsvejledning

Front panel of the DT-9935 LCR Meter showing buttons and display
Figure 5.1: Front panel layout of the DT-9935 LCR Meter with LCD and control buttons.

5.1 Tænd/sluk

  • Tryk på den røde tænd/sluk-knap (MAGT) to turn the meter ON. The meter will perform a self-test and display the default measurement mode.
  • Press and hold the power button to turn the meter OFF.

5.2 Measurement Modes and Functions

Safety Precaution: Always discharge capacitors before testing to prevent damage to the meter and ensure user safety. A warning is printed on the device: "Discharge Capacitor Before Testing".

  • LCR Measurement (Auto): The meter automatically identifies inductance (L), capacitance (C), and resistance (R). Connect the component to the test leads.
  • Function Selection (FUNC): Brug FUNK button to cycle through different measurement parameters such as Cp (parallel capacitance), Cs (series capacitance), Lp (parallel inductance), Ls (series inductance), Rp (parallel resistance), Rs (series resistance), D (dissipation factor), Q (quality factor), and ESR (equivalent series resistance).
  • Frequency Selection (FREQ): Brug FREKV button to select the desired test frequency (e.g., 10 KHz).
  • Series/Parallel Mode (SER/PAL): Brug SER/PAL button to switch between series and parallel equivalent circuit modes for capacitance and inductance measurements, depending on the component and application.
  • Hold Function (HOLD): Tryk HOLDE to freeze the current reading on the display. Press again to release the hold function.
  • Relative Measurement (REL%): Brug REL % button for relative measurements, allowing you to measure the difference from a stored reference value.
  • Sorting Function (SORTING): Brug SORTERING button for component sorting based on predefined criteria.
  • Setup (SETUP): Accesses meter settings.
  • Kalibrering (CAL): Used for calibration procedures.
  • Enter (ENTER)Bekræfter valg.

6. Vedligeholdelse

6.1 Rengøring

Wipe the meter with a dry, soft cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the casing eller display.

6.2 Udskiftning af batteri

Replace the batteries when the low battery indicator appears on the display to ensure accurate measurements and proper operation.

6.3 Opbevaring

Store the meter in a cool, dry place away from direct sunlight, high humidity, and extreme temperatures. If the meter will not be used for an extended period, remove the batteries to prevent leakage and damage.

7. Fejlfinding

  • "OL" or "-OL" Display: This indicates an overrange condition. The measured value exceeds the meter's maximum range for the selected function. Check the component or switch to a higher range if applicable.
  • Ingen skærm/strøm: Check battery installation and ensure the batteries have sufficient charge. Verify that the power button is pressed correctly.
  • Upræcise aflæsninger: Ensure test leads are properly connected and making good contact with the component. Clean the test leads and terminals if necessary. Perform a calibration if readings remain inconsistent.

8. Specifikationer

8.1 Product Parameters (Technical Indicators)

Table of technical specifications for Inductance, Resistance, Capacitance, Q, D, and Theta
Figure 8.1: Detailed technical parameters for various measurement functions.
Parameter Rækkevidde Opløsning Fejl
Induktans
Induktans 20µH – 2000H 0.001 µH ± (0.2 + 5d)
Kondensator
Kondensator 20pF – 20mF 0.001pF ± (0.2 + 3d)
Electronic Resistance
Electronic Resistance 20Ω - 2000MΩ 0.001Ω ± (0.2 + 2d)
DC Electronic Resistance
DC Electronic Resistance 20Ω - 2000MΩ 0.001Ω ± (0.2 + 2d)
Q (Quality Factor)
Q (Quality Factor) 0.000 – 999 0.001
D (Dissipation Factor)
D (Dissipation Factor) 0.000 – 999 0.001
Theta (Phase Angle)
Theta ± 90 grader 1 grader

8.2 Generelle specifikationer

Table of general product features and specifications
Figure 8.2: General product features and operational specifications.
Feature Specifikation
Samplang hastighed 5 gange/minut
Overrange prompt OL or -OL"
Automatisk nedlukning 10 minutter
Driftstemperatur 0~50°C, <80% R. H.
Opbevaringstemperatur -20~60°C
Temperaturkoefficient 0.15(PEC.ACC) /C, <18 # or ≥ 28 #
Sikkerhed Comply with IEC61000EMC standard
Krav til strøm 4 x 1.5V "AA" battery (15A or IE CLR 6 required)
Batterilevetid 30H (Alkaline battery)

9. Brugertips

  • For precise measurements, ensure the test leads are clean and free from corrosion.
  • Always double-check the selected measurement mode and frequency for the component being tested.
  • The meter's automatic identification feature simplifies testing, but understanding the different parameters (Cp, Cs, Lp, Ls, D, Q, ESR) can enhance diagnostic capabilities.

10. Garanti og support

For garantioplysninger, teknisk support eller serviceforespørgsler, kontakt venligst sælgeren eller producenten direkte. Gem din købskvittering som købsbevis i tilfælde af garantikrav.

Documents - CEM – DT-9935
[Pdf] Dokument
کاتالوگ LCRسنج DT 9935 LCR سنج حرفه ای CEM DIGITAL METER ndtkala co 2023 01 |||
CEM The LCR meter could measure Inductance/Capacitance/ Resistance with secondary parameters includ ... ponents could be measured in series or parallel mode according to the DUT impedance automatically. DT-9935 DIGITAL LCR-Q METER I Dual LCD display I Auto LCR smart check and measurement I Series/P...
pointtal: 30 filestørrelse: 115.83 K sideantal: 4 dokumentdato: 2023-01-01
[Pdf] Dokument
MIERNIK IMPEDANCJI CEM DT 9935 INSTRUKCJA OBSŁUGI document 1 instrukcja dt9935 stage centrummiernictwa pl 2023 11 DT9935 Profesjonalny miernik LCR Centrum miernictwa |||
Miernik CEM DT-9935 Instrukcja obslugi MIERNIK IMPEDANCJI CEM DT-9935 INSTRUKCJA OBSLUGI Dokladnie zapoznaj si z instrukcj obslugi przed rozpoczciem pracy. Niestosowanie si do zalece zawartych w instrukcji moe spowodowa zagroenie zdrowia uytkownika oraz uszkodzenie urzdzenia. 1 Miernik CEM DT-9...
pointtal: 29 filestørrelse: 453.37 K sideantal: 12 dokumentdato: 2013-09-12
[Pdf] Dokument
DT 9935 تجهیزات اندازه گیری و Digital Lcr Q Meter Contact CEM INSTRUMENTS INDIA PVT LTD 32A Ganesh Chandra Avenue 4th Floor Kolkata 700013 Tel 033 22151376 22159759 Email info@cem instrumets in india PHOTON DIGITAL LCR METER seeanco |||
CEM The LCR meter could measure Inductance/Capacitance/ Resistance with secondary parameters includ ... ponents could be measured in series or parallel mode according to the DUT impedance automatically. DT-9935 DIGITAL LCR-Q METER I Dual LCD display I Auto LCR smart check and measurement I Series/P...
pointtal: 28 filestørrelse: 182.26 K sideantal: 4 dokumentdato: 2014-09-09
[Pdf] Dokument
Používateľ systému Windows Katalógový list CZ 216 kB DT 9935 RLC merač CEM MICRONIX spol s r o 10024 7253 eshop micronix sk data att 004 |||
DT 9935 CEM DT-9935 je digitln LCR mic. Duln displej s podsvcenm. Men L, C a R s parametry D/ Q Indikace petzen, automatick vypnn Specifikace Indukcnost Rozsahy Rozlisen Zkladn pesnost Kapacita Rozsahy Rozlisen Zkladn pesnost Odpor Rozsahy Rozlisen Zkladn pesnost DC odpor Rozsah Rozlisen Zkladn o...
pointtal: 27 filestørrelse: 216.01 K sideantal: 1 dokumentdato: 2019-10-08
[Pdf] Specifikationer
Traianus lcr tester dt 9935 eng files2 elv public 12 1266 126632 Internet |||
DT-9935 True RMS DPigritoalfMeusltismieotenr aOlszLillCosRkopMeter DT-9935 Features: Five Measurement Frequency exist : 100Hz/ 120Hz/ lk Hz/ l0kHz/ l00kHz Sampling rate: 5 times/sec Overload Indication OL or -OL Auto Power Off: 10 minutes DT-9935 LCR Meter features with an innovative aut...
pointtal: 26 filestørrelse: 456.63 K sideantal: 3 dokumentdato: 2016-11-18
[Pdf] Tilbehør
CEM 2019 PK DT 9935 Professional LCR Meterimage makewebnem netfremstillingweb tCAH3UGsR Document |||
DT-9935 Professional LCR Meter / 5 0HWHU IHDWXUHV ZLWK DQ LQQRYDWLYH DXWRPDWLF VHOHFWLRQ WHFKQRORJ DXWRPDWLFDOO PHDVXULQJ / DQG 5 ZLWK 4 DQG E MXVW WXUQ RQ WKH PHWHU 7KH WHVWLQJ IUHTXHQF LV XS WR N DQG LW FDQ RXWSXW XS WR N WHVW IUHTXHQF ,W SURYLGHV KLJK DFFXUDF ZLWK ...
pointtal: 25 filestørrelse: 175.18 K sideantal: 1 dokumentdato: 2020-02-25
[Pdf] Datablad
karta produktu gotronik pl datasheet products id 4009
Informacje o produkcie Miernik mostek RLC DT-9935 Cena : 465,00 zl 399,00 zl Utworzono 31-07-2017 Nr katalogowy : DT-9935 Producent : CEM Dostpno : Dostpny Stan magazynowy : bardzo wysoki rednia ocena : brak recenzji Gotronik Miernik mostek RLC DT-9935 Miernik mostek RLC pomiarowy DT-9935 produkc...
pointtal: 15 filestørrelse: 2.31 millioner sideantal: 13 dokumentdato: 2017-07-31
Прайс-лист на оборудование ЗАО "Вива-Телеком" - Измерительные приборы
Актуальный прайс-лист на широкий ассортимент измерительных приборов от ЗАО "Вива-Телеком", включальных мильт, CR другие устройства от ведущих производителей.
pointtal: 15 filestørrelse: 234.85 K sideantal: 52 dokumentdato: 2023-03-03
[Pdf] Dokument
Katalógový list ENGMeracia technika Elektrické veličiny RLC LC C merače ručné MICRONIX spol s r o10024 8973eshop micronix sk data att 004 10024 8973 |||
CEM The LCR meter could measure Inductance/Capacitance/ Resistance with secondary parameters includ ... ponents could be measured in series or parallel mode according to the DUT impedance automatically. DT-9935 DIGITAL LCR-Q METER I Dual LCD display I Auto LCR smart check and measurement I Series/P...
pointtal: 15 filestørrelse: 165.84 K sideantal: 4 dokumentdato: 2025-06-02
[Pdf] Dokument
**** Инструкция по эксплуатации Цифровой мультиметр CEM 509308 на instrumentall md dt9935 files shares |||
LCR- DT-9935 . . LCR- 1. 3 2. 4 3. 5 3- . 5 3-2. 5 4. 6 4- . 7 5. 8 5- . 8 5- . 8 6. 9 6-1. 15 7. 20 7- . 20 ...
pointtal: 13 filestørrelse: 281.79 K sideantal: 24 dokumentdato: 2023-03-08
[Pdf] Dokument
Untitledv1cdn imperiatools ru cem 2015 1551192420 |||
2015 , . . CEM -- ISO9001, ISO13485.CE ... 182 x 82 x 55 : 360 : 9V- , . 72 www.cem-instruments.ru E-mail:admin cem-instruments.ru DT-9935 LCR 9935 LCR- , L,C R Q, D . 10kHz, 100kHz. - . ...
pointtal: 13 filestørrelse: 33.83 millioner sideantal: 99 dokumentdato: 2016-06-17
[Pdf] Katalog
CEM Catalogue 2020 version Ampe Kìm đo Công Suất AC DT 3348 240kW DC 1000A 600V True RMS IMALL imall vn 2021 03 |||
ROBUST DURABLE STRONG OVER ANY REQUIREMENTS For over 29 years, CEM, SHENZHEN EVERBEST MACHINERY I ... MC LVD EN: 61326 EN: 61010-1 EN: 61010-02-032 EN: 61010-02-033 EN 61010-1 CAT IV 600V Model 9931 DT-9935 Professional LCR Meter 9935 LCR Meter features with an innovative automatic selection techn...
pointtal: 10 filestørrelse: 25.4 millioner sideantal: 205 dokumentdato: 2019-10-08
[Pdf] Dokument
содержание Aug 5 2021 · PQ3450 PQ3470 трехфазный анализатор мощности регистратор данных PQ3350 и гармоник 382096 3 х фазный анализатор  Kontrolno Izmeritelnoe oborudovanie elec ru files. 08 05 |||
4 - 29 44 56 61 65 , 82 RLC 91 98 11 ... COMPANY 8118 HM8018 LCR- 25 EXTECH LCR200 - 380193 - LCR CEM INSTRUMENTS DT-9930 LCR- DT-9935 LCR- 92 GOOD WILL INSTRUMENT 94 LCR-7800 RLC LCR-78100G RLC 95 93 -6...
pointtal: 9 filestørrelse: 15.78 millioner sideantal: 114 dokumentdato: 2015-08-20