1. Introduktion
This manual provides detailed instructions for the installation, operation, and maintenance of your Haier YR-E17 Wired Controller for central air-conditioning systems. Please read this manual carefully before using the controller and keep it for future reference.

2. Sikkerhedsoplysninger
- Sørg for, at alle elektriske tilslutninger udføres af en kvalificeret fagmand.
- Disconnect power to the air conditioning unit before installation or maintenance.
- Udsæt ikke controlleren for vand eller overdreven fugt.
- Do not attempt to open or repair the controller yourself. Refer to qualified service personnel.
3. Produktet er slutview
The Haier YR-E17 is a wired controller designed for seamless integration with Haier central air-conditioning units. It provides intuitive control over various functions of your air conditioning system, including mode selection, temperature adjustment, and fan speed settings.

4. Specifikationer
| Feature | Specifikation |
|---|---|
| Modelnummer | YR-E17 (0150401331AM) |
| Bruge | Aircondition |
| Kommunikationstype | Ledningskontrol |
| Kanal | 1 |
| Support APP | Ingen |
| Oprindelse | Fastlandet Kina |
| Pakkemål (ca.) | Længde: 28 cm, Bredde: 20 cm, Højde: 3 cm |
| Gross Weight (approx.) | 0.8 kg |
5. Opsætning
The Haier YR-E17 Wired Controller requires professional installation due to its wired connection to the central air-conditioning unit. The following steps outline a general installation process:
- Montering: Choose a suitable indoor location for the controller, typically at eye level and away from direct sunlight or heat sources that could affect temperature readings. Secure the controller to the wall using appropriate screws.
- Ledningsføring: Access the wiring terminal block on the rear of the controller (refer to the 'PRESS TO OPEN' label on the back). Connect the communication wires from your central air-conditioning unit to the corresponding terminals on the controller. Ensure correct polarity and secure connections. Refer to the specific wiring diagram provided with your air conditioning unit for precise connections.
- Strømtilslutning: Once wiring is complete, restore power to the central air-conditioning unit. The controller should power on and display initial settings.
- Indledende konfiguration: Follow the on-screen prompts or refer to the air conditioning unit's manual for any initial configuration steps required for the controller to communicate with the system.

6. Betjeningsvejledning
The YR-E17 controller features an intuitive display and buttons for easy operation. Refer to the diagram below for button identification and basic functions:

Nøglefunktioner:
- TIL/FRA: Tryk for at tænde eller slukke klimaanlægget.
- Mode: Press this key to cycle through available operating modes (e.g., Cooling, Heating, Fan, Auto, Dry). If using a Fresh Air unit, default 3 modes will circulate from cooling-heating-fan.
- Ventilator: Justerer ventilatorhastigheden (f.eks. Lav, Mellem, Høj, Auto).
- Sæt: Used to confirm selections or enter/exit settings menus.
- Tid: Used for setting timers or scheduling operations.
- Temperaturjustering: Use the up/down arrows (typically integrated with other buttons or as separate controls) to increase or decrease the desired temperature.
For detailed information on advanced settings and specific mode functionalities, please refer to the comprehensive manual that came with your air conditioning system.
7. Vedligeholdelse
To ensure optimal performance and longevity of your Haier YR-E17 Wired Controller, follow these simple maintenance guidelines:
- Rensning: Gently wipe the surface of the controller with a soft, dry cloth. Do not use abrasive cleaners, solvents, or wet cloths, as these can damage the display or internal components.
- Inspektion: Periodically check the controller for any visible damage or loose connections. If any issues are observed, contact a qualified technician.
- Undgå forhindring: Ensure that the controller's temperature sensor (if applicable, usually a small vent) is not obstructed by furniture, curtains, or other objects, as this can lead to inaccurate temperature readings.
8. Fejlfinding
If you encounter issues with your Haier YR-E17 Wired Controller, try the following basic troubleshooting steps:
- Controller reagerer ikke: Check if the central air-conditioning unit has power. Ensure all wiring connections are secure. If the issue persists, power cycle the air conditioning unit (turn off at the breaker for a few minutes, then turn back on).
- Forkerte temperaturaflæsninger: Ensure the controller is not exposed to direct sunlight, drafts, or heat sources. Verify that the sensor area is not obstructed.
- Visningsproblemer: If the display is blank or showing errors, try power cycling the air conditioning unit. If the problem continues, professional service may be required.
Brugertips:
- Ensure the controller is functioning correctly after installation by testing all modes and temperature adjustments.
9. Garanti og support
For warranty information and technical support, please refer to the documentation provided with your Haier central air-conditioning system or contact your authorized Haier service provider. Keep your purchase receipt as proof of purchase.





