This manual provides detailed instructions for the safe and efficient operation of your RIDEN RD6018 or RD6018W adjustable DC-DC step-down power supply. The RD6018 series offers precise control over output voltage and current, making it suitable for various applications in scientific research, laboratories, factories, and electronic instrument maintenance. The RD6018W model includes a WiFi communication board for enhanced connectivity.

Please read this manual thoroughly before using the device to ensure proper setup and to prevent damage.

Produkt overview

Video: Overståetview of the RIDEN RD6018 DC Power Supply features and functions.

Specifikationer

FeatureSpecifikation
MærkenavnRIDEN
ModelRD6018 / RD6018W
Input bindtagRækkevidde6-70.00V DC
Udgang VoltagRækkevidde0-60.00V
Udgangsstrømområde0-18.00A
Udgangseffektområde0-1080W
Input bindtage Målingsopløsning0.01V
Udgang Voltage Setting Measurement Resolution0.01V
Output Current Setting Measurement Resolution0.01A
Batteri Voltage Målingsopløsning0.01V
Input bindtage Målenøjagtighed± (1% + 5 cifre)
Udgang Voltage Accuracy (setting vs. measurement)± (0.3% + 3 cifre)
Output Current Accuracy (setting vs. measurement)± (0.5% + 5 cifre)
Batteri Voltage Målenøjagtighed± (0.5% + 3 cifre)
Automatic Cut-off Current Value (charging)100mA
Output Ripple Typical250mV VPP@6A
Arbejdstemperaturområde-10℃ til 40℃
External Sensor Temperature Detection Range-10℃ to 100℃ / 0℉ to 200℉
External Sensor Temperature Detection Accuracy±3℃ / ±6℉
Constant Voltage Mode Response Time2ms (0.1A-5A Load)
Constant Voltage Mode Load Regulation± (0.1% + 2 cifre)
Constant Current Mode Load Regulation± (0.1% + 3 cifre)
Kapacitetsmåleområde0-9999.99 Ah
Energimåleområde0-9999.99Wh
Capacity and Energy Statistical Error±2 %
Buck Working ModeVoltage drop >1V og >10%
OvertemperaturbeskyttelseSystemtemperatur >80℃
Indstilling af skærmens lysstyrke0-5 (6 niveauer i alt)
Skærm2.4-tommer farve HD-skærm
Vægt (med pakke)Omkring 0.68 kg
Produktets dimension167*81*69 mm
Cooling Fan Start ConditionOutput current >8A or System temperature >45℃
Cooling Fan Shut Down ConditionUdgangsstrøm <7.9A og systemtemperatur <45℃

Pakkens indhold

The standard package includes the main RD6018 unit. If purchased with the S800 case, additional components for assembly will be included.

RIDEN RD6018 unit and S800 case components
Image: RIDEN RD6018 unit and S800 case components, including wires, switch, power socket, and WiFi module (for RD6018W).

The S800 case includes internal cables and screws for assembly. Please note that the S800 case does not contain a power supply unit (PSU).

eksploderede view of RD6018 and S800 case components
Billede: Eksploderet view showing the RD6018 main unit, a 1200W PSU, and the S800 case, illustrating how they combine to form a complete adjustable power supply.

Opsætningsvejledning

Power Supply Unit (PSU) Selection and Connection

If you are not ordering the complete set, the RD6018/RD6018W requires a DC input. For AC input, a switching power supply (PSU) is necessary. Ensure the PSU is reliably grounded to prevent leakage risk.

Recommended and not recommended power supply units
Image: Guidelines for selecting an appropriate PSU. Recommended PSUs include custom or famous brand units. Not recommended are AC-DC converters or transformers without rectification/filtering, and banned PSUs like electric bike chargers or second-hand units due to unstable output and potential for high voltage pigge.

Recommended PSUs: Use custom or reputable brand switching power supplies. For 110V AC input, a 1000W PSU is recommended for full RD6018 output. For 220V AC input, a 1200W PSU is recommended.

Not Recommended PSUs: If using an AC-DC converter or transformer, you must add a rectifier and filter. The DC output voltage without load should be lower than 65V. Power grid voltage fluctuations can cause high output voltage and damage the device.

Banned PSUs: Avoid using electric bike chargers, second-hand power supplies, or modified power supplies. These devices are often unstable and can output high voltages, potentially damaging your load.

Important: Before connecting any PSU to the RD6018/RD6018W, use a multimeter to verify its output voltage is stable and within the rated range. Do not connect a damaged or unstable PSU to the RD6018/RD6018W to prevent further damage.

Case Assembly (S800 Case)

The S800 case is designed for the RD6018/RD6018W and compatible AC-DC switching power supplies (800W/1000W). It includes necessary internal cables and screws for assembly.

Indre view of RD6018 circuit board with components labeled
Billede: Intern view of the RD6018 circuit board, highlighting the fan, capacitors, relay, temperature sensor interface, WiFi communication board, clock battery slot (CR1220 battery not included), and input/output terminals.

Assembly Notification: Only individuals with a foundation in electronic and electrical engineering should connect the cables. Ensure all connections are reliably grounded.

Correct and incorrect installation of the RD6018 into the S800 case
Image: Demonstrates the correct installation method for the RD6018 into the S800 case, showing proper alignment and seating.

Ensure the RD6018 unit is installed correctly into the S800 case, as shown in the diagram. Incorrect installation can lead to damage or improper function.

Betjeningsvejledning

Grundlæggende betjening

The RD6018/RD6018W features a digital keypad and encoder potentiometer for easy adjustment of settings. The 2.4-inch color HD display provides clear data visualization.

RD6018 front panel with digital keypad and encoder
Image: Front panel of the RD6018, highlighting the digital keypad and encoder for precise control.

Avancerede funktioner

RD6018 display showing traditional and curve styles
Image: The RD6018 display showing both the traditional data view and the curve style interface for real-time output voltage, current, and power curves.

Beskyttelsesfunktioner

The RD6018/RD6018W incorporates several protection mechanisms to safeguard the device and your connected load:

RD6018 display showing OCP, OVP, and OTP indicators
Image: The RD6018 display indicating various protection statuses like OCP (Over Current Protection), OVP (Over Voltage Protection), and OTP (Over Temperature Protection).

When OCP is active and the output current is lower than the set OCP value, the output will shut down automatically. If the OCP value is higher than the set OCP value, the output will enter constant current mode, suitable for constant current devices like high power LED lamps.

Målenøjagtighed

The device features 4-digit resolution for accurate measurements of output voltage og nuværende.

RD6018 display showing output voltage and current measurements with high resolution
Image: The RD6018 display demonstrating 4-digit resolution for precise output voltage og strømmålinger.

Max Power Limit

The RD6018/RD6018W supports setting a maximum output power, which is convenient for adapting to various input PSUs. When you set the output voltage and current, the device automatically adjusts to ensure that the total power does not exceed the configured maximum power.

RD6018 display showing max power limit setting and calculation method
Image: The RD6018 display illustrating the Max Power Limit feature and its calculation method (Max Power Setting Value = Rated output power of PSU * Full load efficiency).

The maximum power setting range is 10-1080W. For full-scale output with 110V AC input, use a recommended power supply.

Software and APP Connectivity (RD6018W only for APP/WiFi)

The RD6018W model supports both PC software via USB micro cable and mobile APP via WiFi. The RD6018 (without W) only supports PC software via USB micro cable.

RD6018W connected to a WiFi router and a smartphone app
Image: Illustration of the RD6018W connecting to a WiFi router and being controlled via a smartphone application, showing real-time data and control options.
RD6018 connected to a PC running control software
Image: The RD6018 connected to a PC, demonstrating the PC software interface for monitoring and controlling the power supply.

Firmwareopdatering

The device supports firmware upgrades to enhance functionality. Refer to video afsnit 4.3.2 for instructions. Note that firmware updates may take approximately 80 seconds.

RD6018 connected to PC for firmware update
Image: The RD6018 connected to a PC, showing the firmware update process via the PC software.

Opretholdelse

Udskiftning af sikring

The device includes a backup fuse. If the main fuse burns out due to incorrect operation, you can temporarily use the backup fuse (rated for 10A) by inserting it into the socket next to the burned one. For full output capability, it is recommended to remove the damaged fuse and solder a new, appropriate fuse in the same position.

Internal circuit board showing fuse locations
Billede: Intern view of the RD6018 circuit board, indicating the location of the 25A output fuse and a spare fuse slot.

Rensning

Hold enheden ren og fri for støv. Brug en blød, tør klud til rengøring. Brug ikke flydende rengøringsmidler eller opløsningsmidler.

Fejlfinding

Software and Connectivity Issues

Hardware and Physical Issues

Brugertips

Garanti og support

For technical support, warranty claims, or any questions not covered in this manual, please contact the manufacturer directly.

Official Download Links:

Kontaktoplysninger:

Contact information for support including Email, WhatsApp, QQ Group, and WeChat
Image: Contact details for customer support.

Relaterede dokumenter - RD6018 / RD6018W

Preview Riden RD6006-W Laboratoriestrømforsyning Brugermanual
Omfattende brugermanual til Riden RD6006-W laboratoriestrømforsyning, der dækker specifikationer, funktioner, betjening, softwaretilslutning og fejlfinding.
Preview Constant Voltage og konstant strøm jævnstrømsforsyning instruktionsmanual
Omfattende brugsanvisning til Constant Voltage og konstantstrøms jævnstrømsforsyning, der dækker funktioner, betjening og specifikationer for modellerne RD6006, RD6012, RD6018, RD6024, RD6030, RD6006P, RD6012P og RD6018P.
Preview Constant Voltage og konstant strøm DC strømforsyningsinstruktion
Brugsanvisning til Constant Voltage og konstantstrøms jævnstrømsforsyning, der dækker modellerne RD6006, RD6012, RD6018, RD6024, RD6030, RD6006P, RD6012P og RD6018P. Omfatter opsætning, betjening og softwarebrug.
Preview RIDEN AT25 USB 彩屏测试仪使用说明
杭州睿登科技有限公司出品的AT25型号USB彩屏测试仪的使用说明书,包含产品技术指标、功能界面介绍、首次开机与操作指南、APP连接方法及联式
Preview 恒压恒流数控电源使用说明 - RD6006/RD6012/RD6018 系列
杭州睿登科技 RD 系列恒压恒流数控电源 RD6006, RD6006W, RD6012, RD6012W, RD6018, RD6018W 的详细使用说明书,包括技术参数、操作指南、APP及PC软件连接说明。