1. Produktet er slutview

The KING LPWV2715-CT24 is a robust, vandal-resistant electric heater designed for high-traffic and public areas such as detention facilities, public restrooms, and rest areas. Its heavy-duty construction, including a 3/16-inch solid steel frame and grill, provides exceptional durability against impact and abuse. Tamper-resistant screws secure the grill, and controls are recessed to prevent unauthorized access. This unit offers moderate wattage and high airflow to effectively heat entryways and hallways, preventing drafts from affecting the building's core temperature.

KING LPWV2715-CT24 Vandal Resistant Heater, front view

Billede 1: Forside view of the KING LPWV2715-CT24 Vandal Resistant Heater, showcasing dens robuste metal casing and grill.

Nøglefunktioner:

  • Impact/Vandal Resistant: Constructed with a heavy grill and 3/16-inch solid steel frame.
  • Pic-A-Watt Elements: Allows for multiple wattage options to suit specific heating requirements.
  • Tamper Resistant 3 Position Switch: Offers Fan, Heat, and Off settings, designed to prevent unauthorized adjustments.
  • Overophedningsbeskyttelse: Integrated safety feature to prevent overheating.

2. Sikkerhedsoplysninger

Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.

  • Elektrisk installation: This heater operates on 277 Volts and requires hardwiring. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
  • Jording: This heater must be properly grounded to reduce the risk of electric shock.
  • Beliggenhed: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used. Maintain proper clearances from combustible materials as specified in the installation section.
  • Overophedningsbeskyttelse: The heater is equipped with a thermal cut-out to prevent overheating. If the heater shuts off due to overheating, allow it to cool down before attempting to restart. Investigate and correct the cause of overheating.
  • Dæk ikke til: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
  • Opretholdelse: Afbryd strømmen, før du udfører vedligeholdelse eller rengøring.

3. Pakkens indhold

Kontroller, at alle komponenter er til stede og ubeskadigede, når du åbner pakken:

  • KING LPWV2715-CT24 Vandal Resistant Heater Unit
  • Mounting Hardware (typically included)
  • Instruktionsmanual (dette dokument)

Hvis der mangler eller er beskadigede dele, skal du straks kontakte din leverandør.

4. Installation

ADVARSEL: Installation must be performed by a qualified electrician. Disconnect all power to the circuit at the main service panel before attempting any wiring.

4.1 Monteringssted

  • This heater is designed for indoor, wall-mount installation.
  • Choose a location that allows for proper air circulation and maintains required clearances from walls, ceilings, and floors. Refer to local codes for specific clearance requirements.
  • Ensure the mounting surface is structurally sound to support the heater's weight (approximately 36 pounds).

4.2 Elektrisk tilslutning

  • The LPWV2715-CT24 heater requires a dedicated 277 Volt, 60 Hz, single-phase circuit.
  • Varmelegemet trækker 5.4 Amps at 277V, providing 1500 Watts of heat. Ensure the circuit breaker and wiring are appropriately sized for this load.
  • Connect the heater directly to the electrical supply using appropriate hardwiring methods and connectors, following the wiring diagram provided inside the heater's access panel.
  • Sørg for, at alle forbindelser er tætte og sikre.

5. Betjening

Once properly installed and powered, the heater can be operated using its tamper-resistant 3-position switch.

5.1 Power Switch Settings

  • OFF: The heater is completely off, and no heat or fan operation will occur.
  • VENTILATOR: The fan operates continuously without engaging the heating elements. This can be used for air circulation.
  • VARME: The heating elements and fan operate to provide warmth. The heater will cycle on and off to maintain the desired temperature if connected to an external thermostat (not included).

5.2 Wattage Selection (Pic-A-Watt)

The LPWV series heaters feature Pic-A-Watt elements, allowing for field-adjustable wattage settings. Refer to the wiring diagram inside the heater for instructions on how to adjust the wattage to suit specific room requirements. This adjustment should only be performed by a qualified technician with power disconnected.

6. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer optimal ydeevne og levetid for din varmeovn. Afbryd altid strømmen ved afbryderen, før du udfører nogen form for vedligeholdelse.

  • Rensning: Rengør jævnligt varmelegemets yderside med en blød, tør klud.amp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Luftindtag/-udløb: Ensure that the air inlets and outlets are free from dust, lint, and other obstructions. Use a vacuum cleaner with a brush attachment to gently clean the grill and internal components if accessible.
  • Inspektion: Annually inspect the heater for any signs of damage, loose wiring, or unusual wear. If any issues are found, contact a qualified electrician for repair.

7. Fejlfinding

Før du kontakter kundesupport, skal duview følgende almindelige problemer og løsninger:

ProblemMulig årsagLøsning
Varmeapparatet tænder ikke.No power supply; Circuit breaker tripped; Loose wiring.Check circuit breaker; Ensure power switch is in 'HEAT' or 'FAN' position; Consult a qualified electrician to check wiring.
Heater produces no heat, but fan runs.Switch in 'FAN' position; Heating elements failed; Overheat protection activated.Set switch to 'HEAT'; Allow heater to cool if overheat protection tripped; Contact a qualified electrician for element inspection.
Varmeapparatet tænder og slukker ofte.Improper thermostat setting (if applicable); Restricted airflow; Overheat protection cycling.Adjust thermostat setting; Clear any obstructions from air inlets/outlets; Ensure proper clearances.
Usædvanlige lyde eller lugte.Loose components; Dust accumulation on elements; Motor issue.Disconnect power immediately; Inspect for loose parts; Clean heater; Contact a qualified electrician for inspection.

Hvis problemet fortsætter efter at have forsøgt disse løsninger, skal du kontakte kundesupport eller en kvalificeret elektriker.

8. Specifikationer

SpecifikationDetalje
MærkeKONGE
ModelnummerLPWV2715-CT24
Voltage277 volt
Ampslette5.4 Amps
Wattage1500 watt
Produktmål (D x B x H)4" D x 13.75" B x 22.75" H
Varens vægt36 pund
MonteringstypeVægmontering
BrændstoftypeElektrisk
Indendørs/Udendørs brugIndendørs
Speciel funktionOverophedningsbeskyttelse
UPC093319183731
ASINB0G3SWW2XK

9. Garanti og support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official KING webwebsted. Behold din købskvittering som købsbevis i tilfælde af garantikrav.

Fabrikant: KING Electrical Manufacturing

Webwebsted: www.king-electric.com (Eksamplinket, bekræft venligst det officielle webwebsted)

© 2025 KING Electrical Manufacturing. All rights reserved.