Temank POW-SunSmart 10KP

PowMr 10000W Split-Phase Solar Inverter (Model POW-SunSmart 10KP) User Manual

Omfattende instruktioner til installation, drift og vedligeholdelse.

1. Introduktion

This manual provides detailed instructions for the safe and efficient operation of your PowMr 10000W Split-Phase Solar Inverter, Model POW-SunSmart 10KP. This device is a multifunctional solar energy storage inverter designed to integrate solar energy storage, utility charging, and AC sine wave output. It features dual MPPT controllers and supports parallel operation for expanded capacity.

PowMr 10000W Split-Phase Solar Inverter front view

Figur 1: Forside view of the PowMr 10000W Split-Phase Solar Inverter.

2. Sikkerhedsoplysninger

Læs venligst alle instruktioner og advarsler omhyggeligt inden installation og betjening. Manglende overholdelse af disse instruktioner kan resultere i elektrisk stød, brand eller alvorlig personskade. Gem denne manual til senere brug.

  • Installation skal udføres af kvalificeret personale.
  • Sørg for, at al ledningsføring overholder lokale og nationale elektriske forskrifter.
  • Do not connect the positive or negative terminal of the solar panel directly to the ground.
  • Verify correct polarity for all battery and PV connections.
  • Forsøg ikke selv at adskille eller reparere inverteren. Kontakt kvalificeret servicepersonale.
  • Sørg for tilstrækkelig ventilation omkring inverteren for at forhindre overophedning.
  • The inverter is equipped with comprehensive protection features including short circuit, over-current, over-under voltage, overload, backfill, and over-temperature protection.
PowMr Inverter 360 degree protection features

Figure 2: The inverter includes multiple protection mechanisms for safe operation, such as short circuit, over-current, over-voltage, under-bindtage, overload, backfill, and over-temperature protection.

3. Produktet er slutview

3.1 Nøglefunktioner

  • Produktion: Split-phase and single-phase pure sine wave output (120V/240V).
  • Kapacitet: 10000W continuous power, 20000W surge power.
  • MPPT-controller: Built-in dual 200A MPPT controllers with 99.9% efficiency.
  • Parallel drift: Supports up to 6 units in parallel for capacity expansion up to 60kW.
  • Batterikompatibilitet: Compatible with AGM, Gel, Lead-acid, Lithium-ion, and LiFePO4 batteries. Supports batteryless operation.
  • Opladningsmetoder: Four selectable charging modes: Solar Only, Mains Priority, Solar Priority, and Mixed Mains/PV charging.
  • Outputtilstande: Two output modes: Utility Bypass and Inverter Output, with uninterrupted power supply function.
  • Meddelelse: Understøtter CAN-, USB- og RS485-kommunikation.
10KW Split-Phase Hybrid Solar Inverter key features

Figur 3: Overview of the 10KW Split-Phase Hybrid Solar Inverter's main features, including pure sine wave output, dual MPPT, battery compatibility, and parallel operation capability.

4. Hvad er der i æsken

Ved udpakning skal du kontrollere, at alle nedenstående varer er til stede og ubeskadigede:

  • 10000W Solar Inverter
  • Parallel kommunikationskabel
  • 2 x Battery Terminal Lugs
  • 2 x M5 skruer
  • Instruktionsmanual (dette dokument)

Note: WiFi modules, batteries, adapters, plugs, wires, and cables are not included and must be purchased separately if required.

5. Opsætning og installation

Proper installation is critical for the safe and efficient operation of the inverter. Ensure all connections are secure and follow the provided diagrams.

5.1 Valg af sted

  • Install the inverter in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
  • Sørg for tilstrækkelig plads omkring inverteren for at sikre korrekt luftgennemstrømning.
  • Mount the inverter on a non-flammable surface.

5.2 Ledningsforbindelser

The inverter supports both split-phase and single-phase configurations. The PV input is compatible with single crystalline and polycrystalline PV modules. Do not connect the positive or negative terminal of the solar panel to the ground.

Split-Phase Connection Diagram for PowMr Solar Inverter

Figure 4: Detailed split-phase connection diagram illustrating PV input, mains/generator input, AC output, and battery connections. This diagram shows how to connect the inverter for 120V/240V output. For single-phase 120V output, only one live wire (L1 or L2) needs to be connected to the input and output terminals.

5.2.1 PV Input

  • Number of MPPT Trackers: 2
  • Max. PV Array Power: 11000W (5500W per tracker)
  • Max. Input Current: 22A per tracker
  • Starter Voltage: > 150V
  • Maks. Voltage of Open Circuit: 500V DC
  • MPP bindtage-område: 125V-425V DC
  • PV Cable: 10-12 AWG

5.2.2 Mains / Generator Input

  • Input bindtage Range: 90-140Vac per phase
  • Maximum AC Input Current: 120A
  • Frekvensområde: 50/60Hz
  • AC Input Power: 10000W
  • AC Cable: 8-6 AWG

5.2.3 AC-udgang

  • Nominel udgangseffekt: 10000W
  • Nominel output Voltage: 120(P-N)/208(P-P)/240Vac(P-P)
  • Rated AC Frequency: 50/60Hz
  • AC Cable: 8-6 AWG

5.2.4 Batteritilslutning

  • Battery Type: Li-ion/Lead-Acid / User-defined
  • Nominel DC Voltage: 48V DC
  • DC bindtage Rækkevidde: 40-62V DC
  • Maksimal ladestrøm: 200A

5.3 Parallel drift

The inverter supports parallel operation of up to 6 units, allowing for a total power output of up to 60000W. This feature is suitable for expanding system capacity for various applications.

Diagram showing multiple PowMr inverters connected in parallel

Figure 5: Illustration of connecting multiple inverters in parallel for increased power output. Professional guidance is recommended for actual connections.

6. Betjeningsvejledning

6.1 Tænd/sluk

  • Tænd: Ensure all connections are secure. Turn on the battery breaker first, then the AC input breaker (if applicable), and finally the PV input breaker. Press the power button on the inverter.
  • Sluk: Reverse the power-on sequence. Turn off the PV input breaker, then the AC input breaker, and finally the battery breaker. Press and hold the power button to shut down the inverter.

6.2 opladningstilstande

Inverteren tilbyder fire valgbare opladningstilstande:

  • Kun solenergi: Oplader batterier udelukkende fra solenergi.
  • Netprioritet: Prioritizes charging from the utility grid, using solar only when grid power is unavailable.
  • Solprioritet: Prioritizes charging from solar power, using the utility grid only when solar power is insufficient.
  • Blandet net-/PV-opladning: Utilizes both solar and utility power for charging.

These modes can be configured via the inverter's display or the monitoring application.

6.3 Outputtilstande

The inverter supports two output modes:

  • Forsyningsbypass: Belastninger forsynes direkte fra forsyningsnettet.
  • Inverter output: Loads are powered by the inverter (from batteries or solar).

The inverter provides an uninterrupted power supply function, seamlessly switching between modes.

6.4 Battery Compatibility and Activation

The inverter is compatible with various battery types, including AGM, Gel, Lead-acid, Lithium-ion, and LiFePO4. It also supports batteryless operation. For dormant Li-ion batteries, activation can be triggered by either mains power supply or photovoltaic power supply access.

PowMr Inverter compatible with household appliances

Figure 6: The inverter provides 10000W AC output (20000W peak) and can simultaneously output 110Vac and 220Vac, making it compatible with a wide range of household appliances.

7. Overvågning og kontrol

The inverter can be monitored and controlled via the SmartESS App. A Wi-Fi/GPRS data acquisition module is required for this functionality and must be purchased separately.

SmartESS App for monitoring PowMr Inverter

Figure 7: The SmartESS App allows for remote monitoring and control of the inverter. The Wi-Fi/GPRS module (Q2721100111238) is optional and sold separately.

Download the SmartESS App from the App Store or Google Play. Once the Wi-Fi module is installed and configured, you can view real-time system data and adjust settings remotely.

8. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer din inverters levetid og optimale ydeevne.

  • Rensning: Hold inverteren ren og fri for støv. Brug en tør klud til at tørre ydersiden af. Brug ikke flydende rengøringsmidler.
  • Ventilation: Ensure ventilation openings are not blocked. Periodically check for dust accumulation in cooling fins.
  • Forbindelser: Kontrollér regelmæssigt alle elektriske forbindelser for tæthed og tegn på korrosion.
  • Batterikontrol: Hvis du bruger blybatterier, skal du kontrollere elektrolytniveauer og poltilstand i henhold til batteriproducentens retningslinjer.

Warning: Disconnect all power sources (PV, AC, Battery) before performing any maintenance.

9. Fejlfinding

This section provides guidance for common issues. For problems not listed here or if issues persist, contact customer support.

ProblemMulig årsagLøsning
Inverteren tænder ikkeIngen batteriforbindelse; Batterivolumentage too low; Power button not pressed correctly.Check battery connections; Charge battery; Press and hold power button.
Ingen AC-udgangOverbelastning; Kortslutning; Inverterfejl; AC-udgangsafbryder udløst.Reduce load; Check for short circuits; Reset inverter; Check AC breaker.
Ingen solcelleopladningPV indgang voltage too low; PV connections incorrect; MPPT fault.Check PV array for shading or damage; Verify PV wiring; Contact support.
Fejlkode visesSpecifik systemfejl.Refer to the inverter's display for the specific error code and consult the full manual or contact customer support for detailed resolution steps.

10. Tekniske specifikationer

FeatureSpecifikation
ModelnummerPOW-SunSmart 10KP
Nominel udgangseffekt10000W (kontinuerlig)
Surge Power20000W
Nominel output Voltage120/240Vac (Split-phase/Single-phase)
Skift tid10 ms
Maks. PV-indgangseffekt11KW (5500W * 2)
Maks. PV Input Voltage500V jævnstrøm
Maks. PV-indgangsstrøm22A
PV startvolumentage> 150V
PV trådmåler10AWG
Battery Nominal DC Voltage48V jævnstrøm
Maks. Batteri ladestrøm200A
KommunikationsgrænsefladerCAN, USB, RS485
Dimensioner (pakke)25.2 x 18.6 x 6 tommer
Varens vægt59.5 pund

11. Garanti og support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact the manufacturer directly. Ensure you have your product model number (POW-SunSmart 10KP) and serial number ready when contacting support.

Manufacturer: Temank

© 2025 Temank. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.