1. Introduktion
This manual provides instructions for the ZWP RF373E Replacement Remote Control. This remote is designed to operate compatible adjustable bed bases, offering various comfort and positioning features. Please read this manual thoroughly before use to ensure proper operation and to maximize the lifespan of your remote control.
2. Kompatibilitet
The ZWP RF373E Replacement Remote Control is compatible with the following adjustable bed base models:
- Sleep Science RF373E
- Sleep Science JLDK.28.10.17
- Sleep Science JLDK.28.10.19
- Ergomotion Blissful Nights Sleep Science Q-Plus Adjustable Bed Base
Ensure your adjustable bed base model matches one of the listed compatible models for proper functionality.
3. Opsætning: Batteriinstallation
The ZWP RF373E remote control requires three (3) AAA batteries (not included) for operation. Follow these steps to install the batteries:
- Find batterirummets dæksel på bagsiden af fjernbetjeningen.
- Skub dækslet nedad, eller tryk på låsen for at åbne rummet.
- Insert three AAA batteries, ensuring the positive (+) and negative (-) terminals align correctly with the indicators inside the compartment.
- Sæt dækslet til batterirummet på igen, og sørg for, at det klikker sikkert på plads.

Image: Back of the ZWP RF373E remote control, illustrating the open battery compartment and the requirement for three AAA batteries.
Note: Always use new batteries and dispose of old batteries responsibly. If the remote will not be used for an extended period, remove the batteries to prevent leakage.
4. Parring af fjernbetjeningen
To pair your ZWP RF373E replacement remote control with your adjustable bed base, follow these steps:
- Ensure the adjustable bed base is plugged into a power outlet.
- Unplug the power cord of the adjustable bed base from the outlet.
- Vent i cirka 30 sekunder.
- Sæt netledningen tilbage i stikkontakten.
- Inden for 10 sekunder of plugging the power cord back in, simultaneously press and hold the "Gå op" button and the "Foden ned" button on the remote control for 10 seconds.
- The adjustable base will re-pair with the remote control. You may hear a beep or see a light flash on the bed base to confirm successful pairing.

Image: The ZWP RF373E remote control, illustrating the buttons used for the pairing process.
If the remote does not pair on the first attempt, repeat the steps, ensuring you press the buttons within the 10-second window after plugging in the bed base.
5. Betjeningsvejledning
The ZWP RF373E remote control provides intuitive control over your adjustable bed base. Familiarize yourself with the buttons and their functions:

Image: The remote control demonstrating head and foot adjustment capabilities.

Image: The remote control displaying various preset bed positions and their corresponding angles.
5.1. Knapfunktioner
- Pil op/ned: Adjusts the head section of the bed base upwards or downwards.
- Fod op/ned pile: Adjusts the foot section of the bed base upwards or downwards.
- FLAD: Returns the bed base to a completely flat position.
- ZERO G (Zero Gravity): Activates the Zero Gravity preset position, which elevates the head and foot to a position that may reduce pressure on the back. (Typically 40° head, 15° foot).
- 10 MIN / 20 MIN / 30 MIN: These buttons may activate timed massage functions or other timed features depending on your bed base model. Refer to your bed base manual for specific details.
- Power Button (Circle with line): Turns the bed base power on or off, or may activate/deactivate certain functions.
- ZZZ (Sleep Mode): May activate a pre-programmed sleep position or a gentle massage.
- MI (Memory/Custom Position): This button is typically used to set or recall a custom memory position. Consult your bed base manual for instructions on programming memory positions.
5.2. Adjustable Angles
The remote allows for precise adjustment of your bed's head and foot sections. Typical ranges include:
- Hovedjustering: 0-60 grader
- Fodjustering: 0-45 grader
Preset positions available via the remote may include:
- Ingen tyngdekraft: Head 40°, Foot 15°
- Elevision: Head 45°, Foot 15°
- Pregnancy Relaxation: Head 15°, Foot 20°
- Sove: Head 0°, Foot 0° (Flat)
- Prevent Snoring: Head 15°, Foot 0°
- Nursing Mode: Head 50°, Foot 15°

Image: The remote control and bed base, emphasizing stable and responsive operation.

Image: An adjustable bed base, illustrating the quick response and signal strength of the remote control.
6. Specifikationer
| Feature | Detalje |
|---|---|
| Modelnummer | RF373E |
| Mærke | ZWP |
| Fabrikant | ZWP |
| Kompatible enheder | Adjustable Bed Bases (Sleep Science RF373E, JLDK.28.10.17, JLDK.28.10.19, Ergomotion Blissful Nights Sleep Science Q-Plus) |
| Forbindelsesteknologi | Infrarød |
| Maksimal rækkevidde | 10 meter |
| Farve | Sort |
| Materiale | ABS af høj kvalitet |
| Strømkilde | 3 x AAA batterier (medfølger ikke) |
| Varens vægt | 2.08 ounce |
| Knap Antal | Multiple (14 buttons) |
7. Fejlfinding
- Fjernbetjeningen svarer ikke:
- Kontroller, om batterierne er isat korrekt med den korrekte polaritet.
- Udskift gamle batterier med nye AAA-batterier.
- Ensure there are no obstructions between the remote control and the bed base's receiver.
- Verify the remote is within the maximum operating range (up to 10 meters).
- Bed base not moving:
- Sørg for, at sengebunden er tilsluttet en stikkontakt, der fungerer korrekt.
- Check if the remote control is properly paired with the bed base (refer to Section 4: Pairing the Remote Control).
- If the bed base has a power cut-off switch, ensure it is in the "ON" position.
- Intermitterende drift:
- Svage batterier kan forårsage uregelmæssig drift. Udskift dem.
- Ensure the remote is pointed directly at the bed base's receiver.
8. Pleje og vedligeholdelse
- Keep the remote control dry. Moisture can damage electronic components.
- Rengør fjernbetjeningen med en blød, tør klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Undgå at tabe fjernbetjeningen eller udsætte den for kraftige stød.
- Store the remote in a safe place when not in use, away from extreme temperatures.
- If the remote will not be used for an extended period, remove the batteries to prevent corrosion.
9. Garanti og support
For any questions or issues regarding your ZWP RF373E Replacement Remote Control, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific warranty information and customer support contact details.
Note: This manual provides general operational guidance. Specific features and troubleshooting steps for your adjustable bed base may be found in the original bed base user manual.