The Wiltec NW-SOFT-D is an automatic water softener system designed to provide soft, decalcified water for various applications. It utilizes an ion exchange process to remove hardness-causing minerals like calcium and magnesium from your water supply. This system is suitable for household use, small business kitchens, offices, and even for treating water in aquariums. By reducing water hardness, it helps improve the taste of hot beverages, enhances showering experiences, and significantly reduces limescale buildup in appliances such as dishwashers and washing machines, thereby extending their lifespan.

The NW-SOFT-D model boasts a maximum flow rate of 1000 liters per hour and features a 30 kg brine tank capacity for regeneration salt. Its compact and freestanding design ensures versatility and adaptability in various installation environments.

1.1 Produktkomponenter og dimensioner

Wiltec NW-SOFT-D Water Softener main unit
Figur 1: Hoved view of the Wiltec NW-SOFT-D Water Softener. This image displays the complete unit, highlighting its compact and freestanding design.
Wiltec NW-SOFT-D Water Softener dimensions
Figur 2: Overall dimensions of the Wiltec NW-SOFT-D Water Softener. The unit measures approximately 220mm (width) x 390mm (depth) x 1065mm (height), with the control head extending to 480mm in width.

2. Funktionsprincip

The Wiltec NW-SOFT-D water softener operates on the principle of ion exchange. Hard water, containing positively charged calcium (Ca²⁺) and magnesium (Mg²⁺) ions, passes through a special resin bed. This resin contains negatively charged sodium (Na⁺) ions. During the softening process, the resin captures the calcium and magnesium ions from the water and releases sodium ions into the water. This exchange effectively removes the hardness minerals, resulting in soft water.

2.1 Ion Exchange Process

Diagram of ion exchange reaction in water softener resin
Figur 3: Illustration of the ion exchange reaction. Hardness ions (Ca²⁺, Mg²⁺) are exchanged for sodium ions (Na⁺) on the resin beads, effectively softening the water.

2.2 Internal Components and Water Flow

Cross-section diagram of Wiltec NW-SOFT-D water softener showing internal components and water flow during softening and regeneration
Figur 4: Tværsnit view detailing the internal components and water flow. This diagram shows the automatic central control valve, bypass valve, brine line, safety brine valve, pressure tank, resin bed, and cabinet container, illustrating how hard water enters, is softened, and how the regeneration process occurs.

3. Installation

The Wiltec NW-SOFT-D water softener is designed for freestanding installation. Ensure the unit is placed on a level, stable surface in a location with adequate drainage and access to the main water supply and a power outlet.

3.1 Tilslutning af enheden

The unit features standard connections for inlet, outlet, and drain. Refer to the diagram below for proper connection points. It is recommended to install a bypass valve system to allow for maintenance or to temporarily supply unsoftened water if needed.

Detailed diagram of Wiltec NW-SOFT-D water softener connections and bypass valve
Figur 5: Detaljeret view of the connection points and bypass valve assembly. This includes quick couplings, brine line connections, flow meter, adapter couplings, fastening clips, bypass housing, inlet/outlet regulators, and screw connections. The main connections are 26.44 mm (¾") AG.
  1. Vandindtag: Connect the hard water supply to the designated inlet port.
  2. Vandudløb: Connect the softened water outlet to your household plumbing.
  3. Afløbsledning: Connect the drain line to an appropriate drainage point, ensuring it is securely fastened and allows for proper wastewater disposal during regeneration.
  4. Brine Line: Ensure the brine line is correctly connected between the control head and the brine tank.
  5. Strømtilslutning: Sæt strømadapteren i en passende stikkontakt.

3.2 Initial Setup and Salt Filling

Before initial operation, the brine tank must be filled with regeneration salt.

Indre view of the Wiltec NW-SOFT-D brine tank with dimensions
Figur 6: Indre view of the brine tank, showing its capacity and dimensions (approximately 120mm x 175mm for the salt storage area). The tank has a capacity for up to 30 kg of softening salt.
  1. Open the lid of the brine tank.
  2. Fill the tank with common water softening salt (e.g., tablet salt or crystal salt) up to the indicated fill line, or as per the manual's recommendation, ensuring not to overfill. The tank can hold up to 30 kg of salt.
  3. Luk låget forsvarligt.
  4. Set Initial Water Hardness: Access the display on the control head and input the initial hardness of your water supply. This setting is crucial for the automatic controller to optimize the regeneration cycles. Refer to your local water utility for water hardness information or use a water test kit.

4. Betjening

Once installed and configured, the Wiltec NW-SOFT-D operates automatically. The control unit monitors water usage and initiates regeneration cycles as needed, based on the programmed water hardness and capacity settings.

  • Automatisk kontrol: The integrated controller manages the softening and regeneration processes without manual intervention.
  • Regeneration Cycle: When the resin's capacity to exchange ions is depleted, the system automatically initiates a regeneration cycle. During this cycle, a brine solution (saltwater) is drawn from the brine tank and flushed through the resin bed. The concentrated salt solution reverses the ion exchange process, flushing the accumulated calcium and magnesium ions to the drain and recharging the resin with sodium ions.
  • Vis oplysninger: The display on the control head provides information on the system's status, remaining capacity, and current operation mode. Consult the detailed control panel instructions for specific navigation and settings.

5. Vedligeholdelse

Regular maintenance ensures the optimal performance and longevity of your Wiltec NW-SOFT-D water softener.

  • Salt Refilling: The most critical maintenance task is to regularly check and refill the brine tank with water softening salt. The frequency depends on your water usage and hardness. Ensure the salt level does not drop too low to prevent the system from running out of salt during a regeneration cycle.
  • Resin Maintenance: The ion exchange resin itself is designed for long-term use and is virtually maintenance-free, as it is automatically regenerated by the system. No manual cleaning or replacement of the resin is typically required under normal operating conditions.
  • Rensning: Rengør enhedens yderside regelmæssigt med enamp klæde. Undgå at bruge skrappe kemikalier eller slibende rengøringsmidler.
  • Inspektion: Occasionally inspect all connections for leaks and ensure the drain line is clear and unobstructed.

6. Fejlfinding

Dette afsnit indeholder generel vejledning til almindelige problemer. Kontakt kundesupport ved mere komplekse problemer.

  • Water is not soft:
    • Check salt level in the brine tank and refill if necessary.
    • Ensure the initial water hardness setting on the display is correct.
    • Verify that the bypass valve is in the correct operating position (not bypassing the softener).
    • Check for any error codes on the control panel display.
  • Excessive salt consumption:
    • Verify the water hardness setting. An incorrect high setting can lead to more frequent regenerations.
    • Check for leaks in the brine line or tank.
  • Unit not regenerating:
    • Sørg for, at enheden er tilsluttet og modtager strøm.
    • Check for any blockages in the drain line.
    • Consult the control panel for regeneration schedule or error messages.

7. Tekniske specifikationer

The following table provides detailed technical specifications for the Wiltec NW-SOFT-D water softener.

Technical specifications table for Wiltec water softeners, including NW-SOFT-D
Figur 7: Technical Information table. This table provides detailed specifications for various Wiltec water softener models, including the NW-SOFT-D (model 52362), covering capacity at different water hardness levels, nominal flow, max/min pressure, pressure drop, salt consumption per regeneration, and regeneration time.
FeatureSpecification (NW-SOFT-D)
FabrikantWilTec
ModelnummerNW SOFT D (52362)
InstallationsmetodeFrit stående
Max flowhastighed1000 l/t
Brine Tank Kapacitet30 kg (salt)
OprensningsmetodeIonbytning
Særlige funktionerAutomatisk kontrol
Produktmål (L x B x H)22 cm x 48 cm x 106.5 cm
Produktets vægt24.2 kg
MaterialeResin (for ion exchange)
StrømkildeElektricitet
Capacity at 10°dH3500 L
Capacity at 15°dH2200 L
Capacity at 20°dH1800 L
Nominal Flow (20°dH to 8°dH)2 m³/t
Nominal Flow (20°dH to 0.5°dH)0.3 m³/t
Max. Raw Water Pressure6.0 bar
Min. Raw Water Pressure1.0 bar
Pressure Drop Max Flow0.6 bar
Salt Consumption per Regeneration1.28 kg
Regenereringstid30 min

8. Support og garanti

For technical assistance, spare parts, or warranty inquiries, please contact WilTec customer support. Ensure you have your product model number (NW SOFT D) and purchase details available when contacting support.

While specific warranty details are not provided in this manual, standard manufacturer warranties typically cover defects in materials and workmanship for a defined period from the date of purchase. Please refer to your purchase documentation or the manufacturer's official webwebsted for omfattende garantioplysninger.

© 2026 WilTec. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.