1. Introduktion

This manual provides essential information for the installation, operation, and maintenance of your Wiltec NW-SOFT-C1 water softener. This device is designed to effectively reduce water hardness by eliminating limescale, thereby protecting your plumbing and household appliances. It operates on an ion exchange principle, replacing calcium and magnesium ions with sodium ions, which helps prevent limescale buildup on heating elements and improves water quality for various uses, including cooking, showering, and appliance operation. The system features automatic resin regeneration, simplifying maintenance.

2. Sikkerhedsoplysninger

  • Læs alle instruktioner omhyggeligt før installation og drift.
  • Ensure the device is installed by a qualified professional if you are unsure about any steps.
  • Always disconnect the power supply before performing any maintenance or service.
  • Do not operate the device if any parts are damaged. Contact customer support for replacement parts.
  • Use only regeneration salt specifically designed for water softeners.
  • Keep children and pets away from the device during operation and maintenance.

3. Pakkens indhold

Kontroller venligst, at alle varer er til stede i pakken:

  • Wiltec NW-SOFT-C1 Water Softener Unit
  • Brine Tank
  • Necessary accessories for installation (e.g., connection fittings, clips)
  • Brugervejledning (dette dokument)

4. Produktet er slutview

The Wiltec NW-SOFT-C1 water softener is a compact unit designed for efficient water treatment. Below are key components and dimensions.

Wiltec NW-SOFT-C1 Water Softener with overall dimensions

Figure 1: Overall dimensions of the Wiltec NW-SOFT-C1 water softener. The unit measures approximately 215mm in width, 475mm in depth, and 500mm in height.

Indenfor view of the brine tank with internal dimensions

Figur 2: Intern view of the brine tank, showing the space for regeneration salt. The internal dimensions are approximately 120mm by 175mm.

Side view of the water softener showing the outlet pipe

Figur 3: Side view of the water softener, highlighting the outlet pipe with a diameter of 14mm and a height of 400mm from the base.

Diagram illustrating the ion exchange reaction

Figure 4: Diagram explaining the ion exchange process. Hardness ions (Ca2+, Mg2+) are captured by the resin, and sodium ions (Na+) are released into the water, making it soft.

Cross-section diagram of the water softener's internal components

Figure 5: Detailed cross-section diagram showing the internal components of the water softener, including the automatic central control valve, brine hose, safety brine valve, float, pressure tank, suction lance, exchange resin, regenerated brine salt, softened water outlet, and cabinet container.

5. Opsætning og installation

Proper installation is crucial for the optimal performance of your water softener. It is recommended to install the unit in a dry, level area, protected from freezing temperatures and direct sunlight.

5.1 Tilslutningsdiagram

Detailed connection diagram for the water softener

Figure 6: Connection diagram showing the various components and their assembly. This includes quick couplings, brine line, pressure button, adapter couplings, fastening clips, bypass housing, inlet regulator, outlet regulator, large clip, and screw connection. The main connections are 26.44 mm (3/4") AG.

5.2 Installationstrin (generelle retningslinjer)

  1. Placering: Place the water softener on a stable, level surface near the main water supply and a drain. Ensure adequate space for maintenance and salt refilling.
  2. VVS tilslutninger: Connect the main water inlet to the softener's inlet and the softener's outlet to your household's water distribution system. Use the provided fittings and ensure all connections are watertight. A bypass valve system is recommended to allow for maintenance without interrupting the main water supply.
  3. Afløbsledning: Connect the drain line from the softener to an appropriate drain, ensuring there is an air gap to prevent back-siphonage.
  4. Brine Line: Connect the brine line from the control valve to the brine tank.
  5. Elektrisk tilslutning: Sæt netledningen i en jordet stikkontakt.
  6. Indledende udfyldning: Slowly open the main water supply valve to fill the softener with water. Check for leaks.

6. Betjeningsvejledning

The Wiltec NW-SOFT-C1 features automatic operation once initial settings are configured.

6.1 Initial Setup and Hardness Setting

  1. Tænd: Once installed and filled with water, connect the power. The control panel will illuminate.
  2. Indstil vandhårdhed: Use the control panel to set the initial water hardness level. Refer to your local water utility for this information. This setting is crucial for the softener to calculate regeneration cycles accurately.
  3. Tidsindstilling: Set the current time of day on the control panel.
  4. Regeneration Cycle: The system will automatically initiate regeneration cycles based on water usage and the set hardness level.

6.2 Ion Exchange Process

The softener uses a resin bed to remove hardness minerals (calcium and magnesium) from your water. As water passes through the resin, these minerals are exchanged for sodium ions. Over time, the resin becomes saturated with hardness minerals and needs to be regenerated.

6.3 Automatic Regeneration

When the resin bed reaches its capacity, the control unit automatically initiates a regeneration cycle. During this cycle, a brine solution (saltwater) from the brine tank is drawn through the resin bed. This brine solution flushes the accumulated hardness minerals from the resin, which are then sent to the drain. The resin is recharged with sodium ions, restoring its softening capacity. The regeneration process typically takes about 30 minutes.

7. Vedligeholdelse

Regular maintenance ensures the longevity and efficiency of your water softener.

7.1 Saltpåfyldning

The brine tank must always contain enough salt for regeneration. Check the salt level regularly (e.g., monthly). When the salt level drops below one-quarter full, refill the tank with water softener salt. Use only high-quality salt pellets or crystals designed for water softeners.

7.2 Resin Cleaning (Automatic)

The NW-SOFT-C1 features an automatic self-cleaning system for the resin, which prevents fouling and extends the life of the installation. The integrated electrolysis produces automatic cleaning, ensuring prolonged efficiency without manual washing.

7.3 Generel rengøring

Tør enhedens ydre af med adamp klud efter behov. Brug ikke slibende rengøringsmidler eller opløsningsmidler.

8. Fejlfinding

Dette afsnit omhandler almindelige problemer, du kan støde på med dit vandblødgøringsanlæg.

  • Water is still hard:
    • Check salt level in the brine tank. Refill if necessary.
    • Ensure the initial water hardness setting on the control panel is correct.
    • Verify that the bypass valve is not fully open, allowing untreated water to bypass the softener. Adjust if needed to achieve desired hardness (e.g., 5-8 °f).
    • Check for any blockages in the brine line or drain line.
  • Excessive salt consumption:
    • Review the water hardness setting; it might be set too high.
    • Check for leaks in the brine tank or lines.
  • Control panel display issues (e.g., incorrect language):
    • Consult the detailed manual (if available online) for specific instructions on changing language settings, as generic manuals may not cover this.
  • Water pressure drop:
    • Check for sediment buildup in the pre-filter (if installed) or the softener's inlet.
    • Ensure all valves are fully open.

If problems persist, contact Wiltec customer support.

9. Specifikationer

Technical data for the Wiltec NW-SOFT-C1 water softener.

Table of technical information for Wiltec water softeners

Figure 7: Technical information table for various Wiltec water softener models, including the NW-SOFT-C1.

FeatureSpecifikation
FabrikantWilTec
Model reference52360
Dimensioner (L x B x H)21.5L x 47.5B x 50H cm
Flowhastighed500 liter i timen
MaterialeMagnesium, Resin
StrømkildeEl-kabel
InstallationsmetodeFrit stående
OprensningsmetodeIonbytning
Speciel funktionAutomatic regeneration of exchange resin
Vægt10.5 kilo
Min. Tryk1.0 bar
Maks. Tryk6.0 bar
Salt Consumption per Regeneration0.8 kg
Regenereringstid30 min

10. Garanti og support

For warranty information, please refer to the terms and conditions provided at the time of purchase or visit the official Wiltec website. For technical support, spare parts, or any inquiries not covered in this manual, please contact Wiltec customer service.

Wiltec Wildanger Technik GmbH
(Contact details typically found on product packaging or official webwebsted)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.