Aramox TM919BK

Aramox TM919BK Digital Programmable Timer User Manual

Model: TM919BK

1. Introduktion

The Aramox TM919BK is a versatile digital programmable timer designed for controlling electrical appliances, such as household and garden lighting, with precision. It features 24-hour/7-day programming capabilities, allowing for up to 16 ON/OFF settings per day and 15 weekly combinations. Equipped with an LCD screen and an internal battery for program backup, this timer ensures reliable operation even during power interruptions.

Aramox TM919BK Digital Programmable Timer with clear cover open, showing the LCD display and control buttons.

Image: The Aramox TM919BK Digital Programmable Timer with its protective clear cover open, revealing the LCD screen displaying time and day, along with the red control buttons for programming.

2. Sikkerhedsoplysninger

  • Afbryd altid strømmen før installation eller vedligeholdelse for at forhindre elektrisk stød.
  • Installationen skal udføres af en kvalificeret elektriker eller en kyndig person.
  • Sørg for timerens lydstyrketage and current ratings (85-265V AC, 30A) are compatible with your application.
  • Do not expose the device to excessive moisture or extreme temperatures outside its specified operating range (-10℃ to 50℃).
  • Opbevares utilgængeligt for børn.

3. Pakkens indhold

Tjek venligst pakken for følgende varer:

  • 1 x Aramox TM919BK Digital Programmable Timer
  • 1 x brugermanual

4. Produktfunktioner

  • Programmerbar: 24 hours/7 days a week programming with 16 ON/OFF settings per day and 15 weekly combinations.
  • Manuel kontrol: Ability to manually override programmed settings.
  • LCD-skærm: Clear LCD screen with LED indicators for easy readability.
  • DIN-skinnemontering: Designed for easy installation on a 35mm DIN rail.
  • Power Backup: Built-in high-capacity battery retains programmed settings during power failures.
  • Wide Voltage Område: Operates on 85-265V AC.
  • Høj kapacitet: Supports loads up to 30A (5000W).
  • Nedtællingsfunktion: Maximum 24-hour countdown.

5. Opsætning og installation

5.1. Montering

The TM919BK timer is designed for 35mm DIN rail mounting. Securely attach the timer to the DIN rail in your electrical panel or enclosure.

Aramox TM919BK Digital Programmable Timer with clear cover closed, showing the DIN rail mounting clips.

Image: The Aramox TM919BK Digital Programmable Timer with its clear cover closed, providing a view of its compact form factor and the integrated clips for DIN rail mounting.

5.2. Ledninger

Refer to the wiring diagram printed on the timer unit. Ensure all connections are secure and comply with local electrical codes.

  • Terminal 1 og 2: Power input (85-265V AC).
  • Terminalerne 3, 4, 5: Output contacts for the controlled device. Terminal 4 is common, Terminal 3 is normally closed (NC), and Terminal 5 is normally open (NO). Connect your load between Terminal 4 and Terminal 5 for standard ON/OFF control.

After wiring, restore power to the circuit. The timer's LCD display should illuminate.

6. Betjeningsvejledning

Close-up of the Aramox TM919BK timer's control buttons and LCD screen.

Billede: En detaljeret view of the Aramox TM919BK Digital Programmable Timer's front panel, highlighting the LCD display, the 'ON' indicator, and the programming buttons: P, D+, H+, M+, RESET, and MANUAL.

6.1. Initial Setup / Reset

Upon first power-up or after a long period without power, the display may be blank or show incorrect time. Press the NULSTIL button (usually a small recessed button requiring a pointed object) to clear all settings and reset the timer to its default state. The display will show 00:00:00.

6.2. Indstilling af aktuel tid og dag

  1. Tryk på P button once. The display will show the current day of the week (e.g., 'Mo' for Monday).
  2. Trykke D+ to select the correct day of the week.
  3. Trykke H+ for at indstille den aktuelle time.
  4. Trykke M+ for at indstille det aktuelle minut.
  5. Tryk på P button again to exit time setting mode.

6.3. Programmering af tænd/sluk-skemaer

Timeren understøtter op til 16 tænd/sluk-programmer. Hvert program består af en tænd- og en slukketid.

  1. Tryk på P button repeatedly until '1 ON' appears on the display. This is your first ON program.
  2. Trykke D+ to select the desired day(s) for this program. You can choose individual days, weekdays, weekends, or various combinations (e.g., Mo-Fr, Sa-Su, Mo-Su).
  3. Trykke H+ for at indstille ON-timen.
  4. Trykke M+ for at indstille ON-minuttet.
  5. Tryk på P button again. '1 OFF' will appear. This is the OFF time for your first program.
  6. Repeat steps 2-4 to set the OFF day(s), hour, and minute for '1 OFF'.
  7. Fortsæt med at trykke P to cycle through '2 ON', '2 OFF', up to '16 ON', '16 OFF', setting each program as needed.
  8. Når du har indstillet alle de ønskede programmer, skal du trykke på P button until the current time is displayed to save and exit programming mode.

6.4. Manuel tilsidesættelse

De MANUEL button allows you to override the current program state.

  • Trykke MANUEL once to switch the output from AUTO to ON. The 'ON' indicator will light up.
  • Trykke MANUEL again to switch the output from ON to OFF. The 'OFF' indicator will light up.
  • Trykke MANUEL a third time to return to AUTO mode. The timer will follow its programmed schedule.

7. Vedligeholdelse

  • Rensning: Tør timeren af ​​med en tør, blød klud. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
  • Batteri: The internal battery is designed for long-term backup. If the timer frequently loses its settings during power outages, the battery may need replacement by a qualified technician.
  • Inspektion: Kontroller regelmæssigt ledningsforbindelserne for tæthed og tegn på slid.

8. Fejlfinding

ProblemMulig årsagLøsning
Timerdisplayet er tomt.Ingen strømforsyning.Check power connections to terminals 1 and 2. Ensure circuit breaker is ON.
Timeren tænder/slukker ikke på programmerede tidspunkter.Incorrect program settings. Timer is in Manual ON/OFF mode.Review program settings (time, day, ON/OFF). Press MANUEL knappen, indtil 'AUTO' vises.
Belastningen tænder/slukker ikke.Incorrect wiring. Faulty load.Verify wiring to terminals 3, 4, 5. Test the load directly to ensure it is functional.
Timeren mister indstillinger efter strømafbrydelsetage.Internal battery depleted or faulty.The internal battery may need replacement. Contact customer support.

9. Specifikationer

FeatureSpecifikation
ModelTM919BK
Strømforsyning85 ~ 265V AC
Frekvens50/60Hz
Kapacitet30A (resistive load up to 5000W)
Tidsområde1 minut ~ 168 timer
Programmer16 ON/OFF per day, 15 combinations per week
Strømforbrug< 5VA
Gennemsnitlig fejl< 1 second/day
Temperaturområde-10 ~ 50 ℃
Fugtighed< 95 % RF
Montering35mm DIN-skinne
Mål (D x B x H)3.54" x 2.76" x 1.97" (90 mm x 70 mm x 50 mm)
Varens vægt147 gram

10. Garanti og support

For warranty information or technical support, please contact Aramox customer service through your purchase platform or the official Aramox website. Please have your model number (TM919BK) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.