1. Introduktion
Thank you for choosing the Aigostar Ø 120mm Bathroom Extractor Fan. This manual provides essential information for the safe installation, operation, and maintenance of your new ventilation unit. Please read these instructions carefully before use and retain them for future reference.
2. Sikkerhedsoplysninger
Overhold altid følgende sikkerhedsforanstaltninger for at forhindre personskade eller beskadigelse:
- Sørg for, at strømforsyningen er afbrudt før installation, vedligeholdelse eller rengøring.
- Installationen skal udføres af en kvalificeret elektriker i overensstemmelse med lokale el-forskrifter.
- Do not install the fan in areas where flammable gases or vapors may be present.
- Hold hænder og fremmedlegemer væk fra ventilatorbladene under drift.
- Dette apparat er ikke beregnet til brug af personer (inklusive børn) med nedsatte fysiske, sensoriske eller mentale evner, eller mangel på erfaring og viden, medmindre de har fået opsyn eller instruktion i brugen af apparatet af en person, der er ansvarlig for deres sikkerhed.
- Sørg for, at ventilatoren er sikkert monteret for at forhindre den i at falde ned.
3. Produktfunktioner
- Ultra-quiet 14W Operation: Designed for energy efficiency and minimal noise output.
- Effektiv ventilation: Reduces humidity, unpleasant odors, and helps prevent mold growth in various environments.
- Integrated Backdraft Valve: Prevents external air from entering the room when the fan is not operating.
- Holdbar konstruktion: Made from high-strength ABS material, offering anti-corrosion, UV-resistant, antistatic, and waterproof properties.
- Optimeret luftstrøm: High-efficiency helico-centrifugal impeller provides an airflow rate of up to 140 m³/h.

Front view of the Aigostar Ø 120mm bathroom extractor fan, a white square unit with a central fan grille and a small red indicator light. Green leaves are depicted around the fan, symbolizing air movement.

An image illustrating the low noise operation of the Aigostar extractor fan. A person is sleeping peacefully in a bed, with the fan shown operating quietly (20-40 dB). This is compared to the sound levels of nature (0-20 dB) and a rotary telephone (70-80 dB), highlighting the fan's quiet performance.

A split image showing the effect of the Aigostar extractor fan in a bathroom. The top half depicts a steamy bathroom with a bathtub, indicating high humidity. The bottom half shows the same bathroom with the fan installed and operating, with arrows indicating air extraction, resulting in a clear, steam-free environment.
4. Specifikationer
| Specifikation | Værdi |
|---|---|
| Mærke | Aigostar |
| Modelnavn | APC10-F4 |
| Farve | Hvid |
| Elektrisk ventilator design | Udstødningsventilator |
| Strømkilde | Elektrisk med ledning |
| Stil | Industriel |
| Produktdimensioner | 8.5D x 17.2B x 8.5H cm |
| Speciel funktion | Exhaust function, High efficiency |
| Monteringstype | Vægmontering |
| Materiale | Plast |
| Støjniveau | 45 decibel |
| Wattage | 14 watt |
| Luftstrømskapacitet | 140 kubikmeter i timen |
| Hastighed | 2350 RPM |
| Indendørs/Udendørs brug | Indendørs |
| Kontrolmetode | Knap |
| Antal effektniveauer | 1 |
| Motortype | Børstet |
| Størrelse | 120 mm |

Technical diagram showing the dimensions of the Aigostar extractor fan. The front panel measures 172mm x 172mm, and the depth of the main body is 85mm, with a duct diameter suitable for 120-130mm holes. Key specifications like Voltage (200-240V), Power (14W), Airflow (140m³/H), and Frequency (50/60Hz) are also listed.
5. Opsætning og installation
This section outlines the general steps for installing your Aigostar extractor fan. Professional installation is recommended.
5.1 Kontroller før installation
- Verify that the power supply matches the fan's specifications (200-240V, 50/60Hz).
- Ensure the installation location has adequate space for the fan's dimensions (172x172x85mm) and a suitable hole size (120-130mm diameter).
- Confirm that the wall or ceiling material can support the fan's weight and vibration.
5.2 Installationstrin
- Afbryd strømmen: Sluk for hovedstrømforsyningen ved afbryderen, før du påbegynder elektrisk arbejde.
- Forbered åbning: Create a circular opening of 120-130mm diameter in the wall or ceiling at the desired installation point.
- Ledningsføring: Connect the electrical wires to the fan's terminal block according to the wiring diagram provided with the product. Ensure all connections are secure and insulated.
- Montering: Insert the fan body into the prepared opening. Secure the fan to the wall or ceiling using appropriate screws and anchors.
- Fastgør frontpanel: Once the fan body is securely mounted and wired, attach the front grille/panel.
- Prøve: Genopret strømmen og test ventilatorens funktion.

A detailed diagram showing the installation process for the Aigostar extractor fan. It includes an exploded view of components like the panel, body, and wall mounting, with numbered steps for installation on a wall or glass, indicating hole size and cut-out diameter.

Nærbillede view of the backdraft shutter damper mechanism on the rear of the Aigostar extractor fan. It shows two states: 'Normal State' where the shutters are closed, and 'Working State' where they are open, allowing air to pass through. This mechanism prevents external air from entering when the fan is off.
6. Betjeningsvejledning
The Aigostar extractor fan is designed for simple operation.
- Tænd/sluk: The fan is typically connected to a light switch or a dedicated switch in the room. Flipping the switch will turn the fan on or off.
- Indikatorlys: A small red indicator light on the front panel illuminates when the fan is operating.
- Kontinuerlig drift: For optimal humidity and odor control, especially in bathrooms, it is recommended to operate the fan during and after use for a sufficient period.

Diagram illustrating the large air flow and internal components of the Aigostar extractor fan. It shows air intake and air outlet, highlighting uniform air supply, a pure copper motor, and low noise and shake features. The internal structure with the impeller is visible.

A collage showing the Aigostar extractor fan's widespread application in different rooms: a toilet, a kitchen, a living room, and a warehouse. This demonstrates its versatility for various ventilation needs.
7. Vedligeholdelse
Regular cleaning ensures optimal performance and longevity of your extractor fan.
7.1 Rengøring
- Afbryd strømmen: Always turn off and disconnect the power supply before cleaning.
- Fjern frontpanelet: Carefully unclip or unscrew the front grille/panel.
- Rengøring af komponenter: Brug en blød, damp cloth to wipe down the front panel and the fan blades. For stubborn dirt, a mild detergent can be used. Avoid abrasive cleaners or solvents.
- Tør grundigt: Sørg for, at alle dele er helt tørre, før de monteres igen.
- Saml igen: Reattach the front panel securely.
- Gendan strøm: Tænd for strømforsyningen igen.
Note: Do not immerse the fan motor or electrical components in water.
8. Fejlfinding
If you encounter issues with your extractor fan, refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ventilatoren tænder ikke | Ingen strømforsyning; Løse ledninger; Defekt afbryder | Check power at the circuit breaker; Verify wiring connections (consult an electrician); Test or replace the switch. |
| Lav luftgennemstrømning | Blocked grille or duct; Fan blades are dirty | Clean the front grille and fan blades; Check the ducting for obstructions. |
| Overdreven støj | Loose mounting; Obstruction in fan blades; Worn motor bearings | Ensure the fan is securely mounted; Remove any obstructions; If motor bearings are worn, professional repair or replacement may be needed. |
| Backdraft (cold air entering) | Backdraft valve stuck open or damaged | Inspect the backdraft valve for obstructions or damage. Clean or replace if necessary. |
Hvis problemet fortsætter efter at have forsøgt disse løsninger, bedes du kontakte kundesupport.
9. Garanti og support
Aigostar-produkter er fremstillet efter høje kvalitetsstandarder. For information om garantidækning henvises til garantikortet, der fulgte med dit køb, eller besøg den officielle Aigostar-side. webwebsted.
For technical support, spare parts, or any inquiries, please contact Aigostar customer service through the contact information provided on our website or your purchase documentation. Please have your model number (APC10-F4) and purchase date ready when contacting support.