1. Introduktion

This instruction manual provides essential information for the HFBTE TL-1 Large Size Ultrasonic Flow Meter Transducer and its 20-meter twisted shielded cable. This product is designed to work in conjunction with compatible HFBTE ultrasonic flow meter main units, such as the TUF-2000SW, TUF-2000B, TUF-2000M, and TUF-2000F. The TL-1 transducers are clamp-on type sensors, equipped with strong magnets for secure attachment to pipelines, and are suitable for environments with electromagnetic interference.

Vigtig bemærkning: The TL-1 transducers and cable are components of an ultrasonic flow meter system and cannot function independently. They require connection to a compatible ultrasonic flow meter main unit for operation.

2. Produktet er slutview

The HFBTE TL-1 transducer set includes two large-sized clamp-on ultrasonic transducers and a 20-meter twisted shielded cable for connection to the main flow meter unit.

HFBTE TL-1 Large Size Ultrasonic Transducers and 20m Cable
Figure 2.1: HFBTE TL-1 Large Size Ultrasonic Transducers and 20m Cable. This image shows the two TL-1 transducers and the coiled 20-meter cable, which are the main components of this product.
Two HFBTE TL-1 Ultrasonic Transducers with coiled cable
Figure 2.2: Two HFBTE TL-1 Ultrasonic Transducers with coiled cable. The image displays the two blue and grey transducers along with the black 20-meter cable, ready for installation.
Hand holding two HFBTE TL-1 Ultrasonic Transducers with coiled cable
Figure 2.3: Hand holding two HFBTE TL-1 Ultrasonic Transducers with coiled cable. This perspective shows the compact size of the transducers when held, with the cable coiled in the background.

2.1 TL-1 Transducers

The TL-1 transducers are designed for large pipe diameters and feature a robust construction. They are equipped with strong magnets for easy and secure attachment to the exterior of the pipeline, eliminating the need for pipe cutting or flow interruption.

2.2 20-meter Cable

The included 20-meter twisted shielded wire cable connects the TL-1 transducers to the ultrasonic flow meter main unit. The shielding helps to minimize electromagnetic interference, ensuring reliable signal transmission.

Close-up of HFBTE TL-1 Ultrasonic Transducer showing model and temperature range
Figure 2.4: Close-up of HFBTE TL-1 Ultrasonic Transducer. The label on the transducer indicates 'ULTRASONIC TRANSDUCER', 'MODEL: TL-1', and 'TEMP: -30°C ~ 90°C', confirming its specifications.
Top view of two HFBTE TL-1 Ultrasonic Transducers with coiled cable
Figur 2.5: Øverst view of two HFBTE TL-1 Ultrasonic Transducers with coiled cable. This image provides a clear view of the top surface of both transducers, showing their connection points and the coiled cable.

3. Specifikationer

FeatureSpecifikation
TransducermodelTL-1 (Large Size)
Compatible Pipe DiameterDN300 ~ DN6000mm
Temperaturområde-30°C til 90°C (-22°F til 194°F)
Transducer Dimensions (L x W x H)69 mm x 39 mm x 44 mm
KabeltypeTwisted Shielded Wire
Kabellængde20 meter
MaterialePlast
Varens vægt (ca.)1.1 pund (samlet pakke)
KompatibilitetTUF-2000SW, TUF-2000B, TUF-2000M, TUF-2000F Ultrasonic Flow Meters

4. Opsætning og installation

Proper installation of the TL-1 transducers is crucial for accurate flow measurement. Always refer to the specific instruction manual of your HFBTE ultrasonic flow meter main unit (e.g., TUF-2000B) for detailed connection and configuration procedures.

4.1 Tilslutning af kablet

  1. Ensure the ultrasonic flow meter main unit is powered off before making any connections.
  2. Connect the 20-meter twisted shielded cable to the TL-1 transducers. Ensure the connections are secure and properly sealed to prevent moisture ingress.
  3. Connect the other end of the cable to the designated transducer input ports on your HFBTE ultrasonic flow meter main unit. Pay attention to polarity if specified by your main unit's manual.

4.2 Transducer Placement

The TL-1 transducers are clamp-on type, meaning they attach to the exterior of the pipe. The exact spacing and orientation of the transducers on the pipe will depend on the pipe material, diameter, and the specific settings of your ultrasonic flow meter main unit. Consult your main unit's manual for precise placement instructions, including:

  • Rørforberedelse: Ensure the pipe surface where the transducers will be placed is clean, smooth, and free of rust, paint, or other coatings that could interfere with ultrasonic signal transmission.
  • Koblingsgel: Apply a suitable ultrasonic coupling gel between the transducer faces and the pipe surface to ensure good acoustic contact.
  • Sikker vedhæftning: Use the strong magnets on the transducers to firmly attach them to the pipe. Additional clamping mechanisms may be provided with your main unit for extra security.
  • Upstream/Downstream Placement: Correctly identify and place the 'UP' (upstream) and 'DN' (downstream) transducers according to the flow direction and your main unit's requirements.

5. Betjeningsvejledning

Once the TL-1 transducers and cable are correctly installed and connected to the HFBTE ultrasonic flow meter main unit, the operation of the system is primarily controlled via the main unit. The transducers function by sending and receiving ultrasonic signals through the fluid in the pipe, allowing the main unit to calculate flow rate.

For detailed operating procedures, including calibration, parameter settings, and data interpretation, please refer to the comprehensive user manual provided with your specific HFBTE ultrasonic flow meter main unit (e.g., TUF-2000B).

Video 5.1: HFBTE TL-1 Transducer and Cable Overview. This video provides a visual demonstration of the HFBTE TL-1 ultrasonic transducers and the 20-meter cable, showcasing their physical appearance and components.

6. Vedligeholdelse

To ensure the longevity and accurate performance of your HFBTE TL-1 transducers and cable, follow these maintenance guidelines:

  • Renhed: Regularly clean the transducer faces and the pipe surface where they are mounted. Any dirt, grease, or residue can impair acoustic coupling and affect measurement accuracy.
  • Kabelinspektion: Periodically inspect the 20-meter cable for any signs of wear, cuts, or damage to the insulation. Damaged cables should be replaced to prevent signal loss or electrical hazards.
  • Sikker montering: Verify that the transducers remain securely clamped to the pipe. Vibrations or external impacts can cause displacement, leading to inaccurate readings.
  • Opbevaring: When not in use, store the transducers and cable in a clean, dry environment, away from extreme temperatures and direct sunlight.

7. Fejlfinding

If you encounter issues with your HFBTE TL-1 transducers or cable, consider the following common troubleshooting steps. For more in-depth diagnostics, refer to the troubleshooting section of your HFBTE ultrasonic flow meter main unit's manual.

7.1 No Flow Reading or Erratic Readings

  • Tjek forbindelser: Ensure the 20-meter cable is securely connected to both the transducers and the main flow meter unit.
  • Placering af transducer: Verify that the transducers are correctly spaced and oriented on the pipe according to the main unit's manual. Incorrect spacing is a common cause of errors.
  • Koblingsgel: Confirm that sufficient ultrasonic coupling gel is applied between the transducers and the pipe surface, and that there are no air gaps.
  • Rørtilstand: Ensure the pipe material and wall thickness entered into the main unit are accurate. Check for internal pipe lining or heavy corrosion that might obstruct the ultrasonic signal.
  • Fluid Properties: Confirm the fluid in the pipe is suitable for ultrasonic measurement (e.g., not heavily aerated or containing excessive solids).

7.2 Cable Damage

If the 20-meter cable is visibly damaged (cuts, fraying), it may lead to signal loss or intermittent readings. Replace damaged cables with genuine HFBTE replacement parts to ensure compatibility and performance.

8. Garanti og support

For information regarding product warranty, technical support, or replacement parts, please contact HFBTE customer service or visit the official HFBTE website. When contacting support, please have your product model (B0F3X5G34P) and any relevant purchase information available.