Temank POW-SunSmart 10KP-F

Temank PowMr 10000W Split-Phase Solar Inverter (Model POW-SunSmart 10KP-F) User Manual

Model: POW-SunSmart 10KP-F | Brand: Temank

1. Introduktion og produktoversigtview

This manual provides essential information for the safe and efficient operation of your Temank PowMr 10000W Split-Phase Solar Inverter, Model POW-SunSmart 10KP-F. This advanced solar energy storage inverter integrates solar energy storage, utility charging, and AC sine wave output capabilities. It features dual MPPT controllers for high efficiency and supports various battery types, including LiFePO4, Lead-Acid, and batteryless operation.

Nøglefunktioner omfatter:

  • Split-phase and single-phase pure sine wave output (120V/240V).
  • Parallel operation support for up to 6 units, expanding capacity to 60kW.
  • Built-in dual 200A MPPT controller with 99.9% efficiency.
  • Compatibility with AGM, Gel, Lead Acid, Lithium-ion, and LiFePO4 batteries, and batteryless operation.
  • Four charging modes and two output modes with uninterrupted power supply.
  • Comprehensive 360° protection against short circuit, over-current, over/under voltage, overload, and more.
PowMr 10000W Split-Phase Solar Inverter
Figur 1: Forside view of the PowMr 10000W Split-Phase Solar Inverter.

The inverter is designed for various off-grid backup and self-use applications, suitable for homes, cabins, RVs, trailers, and boats.

2. Sikkerhedsoplysninger

Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

  • Kvalificeret personale: Installation og vedligeholdelse skal udføres af kvalificeret personale.
  • Afbryd strømmen: Frakobl altid alle strømkilder (PV, batteri, forsyningsselskab), før du udfører vedligeholdelse eller ledningsføring.
  • Korrekt jording: Sørg for, at inverteren er korrekt jordforbundet for at forhindre elektrisk stød.
  • Korrekt polaritet: Observe correct polarity for all DC connections (battery, PV) to avoid damage.
  • Ventilation: Sørg for tilstrækkelig ventilation omkring inverteren for at forhindre overophedning.
  • Miljøforhold: Do not expose the inverter to rain, snow, liquids, or excessive dust.
  • Interne komponenter: Do not attempt to open or repair the inverter. Refer to authorized service personnel.
PowMr Inverter 360 Degree Protection Features
Figure 2: The inverter includes multiple protection features such as short circuit, over-current, over/under voltage, overload, backfill, and over-temperature protection.

3. Product Components and What's in the Box

The PowMr 10000W Split-Phase Solar Inverter is a robust unit designed for reliable performance. Below is an overview of its main components and the contents of the packaging.

PowMr Inverter Production Overview Diagram
Figur 3: Produktion overview showing the LCD screen, LED indicators, touchable keys, ON/OFF rocker switch, PV input, BAT input, Dry contact, CAN/RS485-2 port, RS485-1 port, USB-B port, Grounding Screw, AC OUT, AC IN, AC INPUT breaker, and Parallel Communication Port.

Pakkeindhold:

  • 1 x 10000W solar inverter
  • 1 x Parallel communication cable
  • 2 x Battery Terminal Lugs
  • 2 x M5 skruer
  • 1 x Brugsanvisning (dette dokument)

4. Opsætning og installation

Proper installation is crucial for the safe and efficient operation of your solar inverter. Follow these steps carefully.

4.1 Montering af inverteren

Mount the inverter on a sturdy, non-flammable surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for airflow.

PowMr Inverter mounted on a wall
Figure 4: The inverter should be securely mounted on a vertical surface, ensuring proper ventilation.

4.2 Ledningsforbindelser

Before making any electrical connections, ensure all circuit breakers are in the OFF position. Observe correct polarity for all connections.

4.2.1 Batteritilslutninger

Connect the positive and negative terminals of your 48V battery bank to the corresponding battery input terminals on the inverter. Use appropriate gauge wiring and ensure secure connections. The inverter supports various battery types, including LiFePO4 and Lead-Acid batteries.

Video 1: This video demonstrates the wiring process for the POW-SunSmart 10K inverter, including battery connections. Ensure all circuit breakers are in the OFF position before wiring.
Battery connection points on inverter
Figure 5: Close-up of the battery connection terminals on the inverter, showing positive and negative inputs.

4.2.2 PV-indgangsforbindelser

The inverter features dual MPPT inputs. Connect your solar panel arrays to the PV1 and PV2 input terminals. Each input supports up to 5500W, with a maximum PV input voltage of 500Vdc and current of 22A. Ensure PV starting voltage er større end 150V.

Dual MPPT PV Input Diagram
Figure 6: Diagram illustrating the dual MPPT PV inputs, allowing connection of solar panels with different specifications and quantities for optimized energy harvesting.
Video 2: This video provides a wiring guide for the POW-SunSmart 10K inverter, including detailed steps for connecting PV inputs to the distribution box.

4.2.3 AC-indgangs- og udgangsforbindelser

Connect the utility grid or generator to the AC input terminals. The inverter supports 120/240Vac split-phase/single-phase output. Connect your loads to the AC output terminals. Ensure all AC wiring adheres to local electrical codes and safety standards.

Split-Phase Connection Diagram
Figure 7: A detailed diagram showing the split-phase connection for the inverter, including PV input, AC input (mains/generator), battery, and AC output to loads. Note the specific wiring for L1, L2, N, and PE (ground).
Video 3: This video explains three different wiring methods for the POW-SunSmart 10K solar inverter, focusing on AC output configurations for various load requirements.

4.2.4 Jordforbindelse

Proper grounding is essential for safety. Connect the inverter's grounding terminal to a reliable earth ground. Refer to local electrical codes for grounding requirements.

4.2.5 Parallel Communication (Optional)

For parallel operation of multiple inverters (up to 6 units), connect the parallel communication cables between the inverters. This allows for capacity expansion up to 60kW.

Parallel Connection Diagram for Multiple Inverters
Figure 8: Diagram illustrating parallel connection configurations for two, three, and six inverters to achieve higher power output and different phase systems.
Video 4: This video provides a detailed guide for parallel operation of three POW-SunSmart 10KP inverters, covering wiring and configuration steps.

5. Betjeningsvejledning

Once the inverter is installed and wired correctly, you can proceed with its operation.

5.1 Indledende opstart

After all connections are secure and verified, turn on the battery circuit breaker, then the PV input breakers, and finally the AC input breaker. The inverter's LCD display will light up, indicating its operational status.

Video 5: This video demonstrates BMS communication protocol settings for the inverter and battery, including initial power-up and display verification.

5.2 LCD-skærm og indstillinger

The LCD display provides real-time monitoring of photovoltaic system operating data. Use the touchable keys to navigate through menus and configure settings.

LCD HD Display Screen showing real-time data
Figure 9: The LCD HD display screen provides real-time monitoring of photovoltaic system operating data, including battery voltage, output voltage, og strømflow.

5.3 opladningstilstande

The inverter offers four charging modes:

  • Kun solenergi: Charges battery exclusively from solar power.
  • Netprioritet: Prioritizes utility power for charging, using solar as a supplement.
  • Solprioritet: Prioritizes solar power for charging, using utility as a supplement.
  • Blandet net-/PV-opladning: Utilizes both utility and PV for charging.

5.4 Time-Slot Charging/Discharging Function

The POW-SunSmart series is equipped with a time-slot charging and discharging function, allowing users to set different charging and discharging periods according to local peak and valley tariffs. This optimizes utility power and PV energy usage, potentially saving electricity costs.

Time-Slot Charging and Discharging Function Diagram
Figure 10: Diagram explaining the time-slot charging and discharging function, which allows users to optimize energy usage based on electricity tariffs.

5.5 Strømbesparende tilstand

Enable power saving mode to conserve energy. When the load power drops below 50W, the inverter will switch off after a 5-minute delay. It will automatically restart when the load exceeds 50W.

Power Saving Mode Feature
Figure 11: Illustration of the power saving mode, which automatically turns off the inverter for low loads and restarts for higher loads.

5.6 Overvågning og styring via app

The inverter supports CAN, USB, and RS485 communication. Optional WiFi/GPRS data acquisition modules (purchased separately) allow for remote monitoring and control via the SMARTESS App, available on the App Store and Google Play.

SMARTESS App Monitoring and Control
Figure 12: The SMARTESS App allows users to monitor and control the solar inverter system remotely, providing real-time data and settings adjustments.

6. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer din inverters levetid og optimale ydeevne.

  • Rensning: Periodically clean the exterior of the inverter and ensure the detachable insect-proof screen is free from debris to maintain proper airflow.
  • Forbindelser: Kontrollér regelmæssigt alle elektriske forbindelser for tæthed og tegn på korrosion.
  • Ventilation: Ensure the cooling fans are operating correctly and are not obstructed. The inverter is equipped with four cooling fans for efficient heat dissipation.
  • Inspektion: Inspect the unit for any visible damage or unusual noises.
Inverter Cooling Fans and Detachable Screen
Figure 13: The inverter features a detachable insect-proof screen for easy cleaning and intelligent cooling fans to prevent overheating.

7. Fejlfinding

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For complex problems, contact customer support.

  • Ingen strøm: Check all circuit breakers (battery, PV, AC input) to ensure they are in the ON position. Verify battery connections and voltage.
  • Ingen AC-udgang: Check AC output circuit breakers. Ensure loads are within the inverter's rated capacity.
  • Fejlindikatorer: If a fault indicator is lit on the LCD, refer to the inverter's display for specific fault codes and consult the full manual for detailed explanations and solutions.
  • Overbelastningsbeskyttelse: If the inverter shuts down due to overload, reduce the connected load and restart the unit.

8. Tekniske specifikationer

FeatureSpecifikation
Nominel udgangseffekt10000W (kontinuerlig), 20000W (bølge)
Nominel output Voltage120/240 V AC (splitfase/enkeltfase)
Batteri Voltage48Vdc (40-60Vdc range)
Maks. PV-indgangseffekt11KW (5500W * 2)
Maks. PV Input Voltage500V jævnstrøm
Maks. PV-indgangsstrøm22A
MPPT bindtagRækkevidde125-425VDC
Maks. MPPT Ladestrøm200A (2 * 100A)
AC -indgang VoltagRækkevidde90-140Vac per phase
Skift tid10 ms
MeddelelseCAN, USB, RS485
Varens vægt59.5 pund
Pakkedimensioner31 x 23 x 10 tommer

9. Garanti og support

For warranty information and technical support, please refer to the documentation included with your product or visit the official Temank webwebsted. Behold din købskvittering som købsbevis i tilfælde af garantikrav.

For further assistance, you may contact the seller Y-SOLAR directly via Amazon's messaging system or refer to the contact information provided in your product packaging.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.