DOITOOL 38V6234331U9KUJYFP4DM

DOITOOL Ultrasonic Water Level Sensor Tank Gauge Liquid Level Meter User Manual

Model: 38V6234331U9KUJYFP4DM

1. Introduktion

This manual provides detailed instructions for the installation, operation, and maintenance of your DOITOOL Ultrasonic Water Level Sensor Tank Gauge Liquid Level Meter. This device is designed to monitor water levels and temperatures in outdoor tanks from the comfort of your indoor living space, offering a transmission range of up to 100 meters in open fields.

2. Produktfunktioner

  • Indendørs temperaturvisning (°C/°F)
  • Tank temperature display (°C/°F)
  • Water level displayed on a 10-bar graph
  • Records minimum and maximum indoor and tank temperatures
  • Adjustable tank level alarm modes (high/low)
  • Tank empty alert function
  • Time display (12/24hr format)
  • Time alarm mode
  • Tank level updated every 30 seconds or 3 minutes
  • Transmissionsrækkevidde: 100m (åbent felt)
  • Tank level/depth measurement range: 0.5m to 15m
  • Minimum air gap requirement: 0.5m
  • Receiver unit can be wall-mounted or placed on a surface using its stand

3. Pakkens indhold

  • 1 x Liquid Level Meter Receiver Unit
  • 1 x Ultrasonic Transmitter Unit
  • Brugervejledning (dette dokument)

Note: Batteries are not included. The receiver unit typically requires 2x AA batteries, and the transmitter unit requires 6x AAA batteries.

4. Specifikationer

SpecifikationVærdi
Modtagerenhedens dimensioner10.5 x 9.3 x 2.5 cm (L x B x H)
Receiver Unit Weight8 ounce
MaterialePlast
Tank Level/Depth Range0.5m til 15m
Minimum Air Gap0.5m
Transmission Range100m (åben mark)
Power (Receiver)Batterier (medfølger ikke)
Strøm (sender)Batterier (medfølger ikke)

5. Opsætning og installation

5.1 Batteriinstallation

Before installation, insert the required batteries into both the receiver and transmitter units. Ensure correct polarity.

Back of the receiver unit with battery compartment open

Billede: Bag view of the receiver unit, showing the battery compartment with the cover removed. This is where the receiver unit's batteries are inserted.

5.2 Transmitter Unit Installation

The transmitter unit is installed at the top of your water tank. Follow these guidelines for optimal performance:

  • Antenne: Ensure the antenna is positioned for clear signal transmission.
  • Balance Bubble: Use the integrated balance bubble to ensure the transmitter is level for accurate readings.
  • Montering: Secure the transmitter using screws through the designated bracket.
  • Sensorplacering: The ultrasonic sensor should have a clear path to the water surface. Ensure there is a minimum air gap of 0.5 meters (H1 height) between the sensor and the maximum water level.
  • Tank Opening: The tank opening for the sensor should be at least 20cm in diameter (Ø > 20CM) to prevent interference from tank walls.
Diagram showing transmitter components, installation sketch, and examples of wrong installation

Billede: A detailed diagram illustrating the components of the transmitter unit (antenna, balance bubble, sensor), a setup sketch for proper installation on a tank, and visual examples of incorrect installation methods to avoid.

5.3 Receiver Unit Placement

The receiver unit can be placed indoors. It features a stand for desktop use or can be mounted on a wall using the integrated hooks. Position it in a location where the signal from the transmitter is strong and clear.

6. Betjeningsvejledning

The receiver unit displays various information on its screen, including indoor temperature, tank temperature, water level, and time. It features several buttons for configuration and viewing data.

Front view of the receiver unit display with buttons

Billede: The front of the receiver unit, showing the digital display and control buttons: 'set', '+/max/min', '-/tank', and 'alarm'.

6.1 Display overview

  • T.ANK: Displays the water level in the tank, often represented by a 10-bar graph and a percentage.
  • °C/°F: Indicates temperature units.
  • Indendørs temperatur: Shows the ambient temperature where the receiver is located.
  • Tank temperatur: Shows the temperature of the water in the tank.
  • TID: Viser det aktuelle klokkeslæt.

6.2 Knapfunktioner

  • SÆT: Used to enter settings mode for time, alarms, and units. Press to cycle through settings.
  • +/MAX/MIN: I normal tilstand, tryk for at view maximum and minimum recorded temperatures. In settings mode, use to increase values.
  • -/TANK: In normal mode, press to switch between tank level display units (meters/feet). In settings mode, use to decrease values.
  • ALARM: Used to set or activate/deactivate various alarms (e.g., high/low water level, empty tank).

6.3 Indstilling af tid og alarmer

  1. Tryk på SÆT button to enter time setting mode. Use + or - for at justere timer og minutter. Tryk på SÆT igen for at bekræfte.
  2. To set water level alarms, press the ALARM knap. Brug + or - to adjust the high or low water level thresholds. Press ALARM again to confirm and activate.
  3. An audible alarm will sound when a set condition (e.g., tank empty, high/low level) is met.

7. Vedligeholdelse

  • Rensning: Wipe both units with a soft, dry cloth. Do not use abrasive cleaners or immerse units in water.
  • Udskiftning af batteri: Replace batteries in both units when the low battery indicator appears on the receiver display. Ensure to use fresh batteries of the correct type and size.
  • Senderkontrol: Periodically check the transmitter unit for any obstructions or debris that might interfere with the ultrasonic sensor's operation. Ensure it remains level.

8. Fejlfinding

  • No Reading on Receiver:
    • Kontrollér batterierne i begge enheder, og udskift dem om nødvendigt.
    • Ensure both units are within the 100m transmission range and there are no significant obstructions.
    • Verify the transmitter is correctly installed and level.
  • Inaccurate Water Level:
    • Confirm the transmitter is level and the sensor has a clear path to the water.
    • Ensure the minimum air gap of 0.5m is maintained.
    • Check for debris or buildup on the sensor.
  • Temperature Readings Incorrect:
    • Ensure the units are not exposed to direct sunlight or extreme heat sources that could affect readings.

9. Sikkerhedsoplysninger

  • Forsøg ikke selv at skille enheden ad eller reparere den. Kontakt kvalificeret personale for service.
  • Hold enheden væk fra ekstreme temperaturer, direkte sollys og fugt.
  • Bortskaf batterier i henhold til lokale regler. Bland ikke gamle og nye batterier eller forskellige typer batterier.
  • Denne enhed er ikke et legetøj. Holde utilgængeligt for børn.

10. Garanti og support

For warranty information and technical support, please refer to the retailer where you purchased the product or visit the official DOITOOL brand webwebsted. Gem din købsbevis til garantikrav.

You can find more information about DOITOOL products at the DOITOOL Store.

© 2025 DOITOOL. All rights reserved.