Diversitech CP-22LPT

Asurity by Diversitech CP-22LPT Low Profile Brugervejledning til kondensatpumpe

Model: CP-22LPT

Indledning

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Asurity by Diversitech CP-22LPT Low Profile Condensate Pump. This pump is designed to automatically evacuate condensate or water discharge from HVACR equipment, offering a vertical lift capability of up to 22 feet. Its low-profile design makes it suitable for installations in tight spaces.

Sikkerhedsoplysninger

Læs alle instruktioner omhyggeligt før installation og betjening. Manglende overholdelse af disse instruktioner kan resultere i materielle skader, personskade eller død.

  • Elektrisk fare: Disconnect power before servicing. This unit operates on 110 Volts. Ensure all electrical connections comply with local codes.
  • Vandhazard: This pump handles water. Ensure proper drainage and prevent water damage.
  • Installation: Install the pump in a location where it is accessible for maintenance and inspection.
  • Tiltænkt brug: Use this pump only for its intended purpose of evacuating condensate from HVACR equipment.
  • UL-listet: This product is UL listed, meeting electrical and mechanical safety standards for water pumps.

Pakkens indhold

Kontroller, at alle elementer er til stede, før installationen påbegyndes:

  • Asurity by Diversitech CP-22LPT Condensate Pump
  • 20 ft Clear Vinyl Tubing
  • 4 ft Safety Switch Wire (pigtail)

Produkt overview

The Asurity CP-22LPT condensate pump features a compact design with advanced functionalities for reliable condensate removal.

Asurity CP-22LPT Condensate Pump with Clear Tubing

Billede 1: The Asurity CP-22LPT low profile condensate pump shown with the included clear vinyl tubing. The pump features a red base and a black motor housing with ventilation slots and an outlet port.

Asurity CP-22LPT Condensate Pump with Tubing and Safety Switch Wire

Billede 2: En top-down view of the Asurity CP-22LPT condensate pump, accompanied by the coiled clear vinyl tubing and the yellow safety switch wire. This image highlights all primary components included with the unit.

Side View of Asurity CP-22LPT Condensate Pump

Billede 3: A side perspective of the Asurity CP-22LPT condensate pump, illustrating its low-profile design. This view emphasizes the compact dimensions suitable for installation in confined spaces.

Nøglefunktioner:

  • LED Status Indicator Lights (Power, Run, Alarm)
  • Vibration Dampening System for quiet operation
  • Integrated Safety Switch with 4 feet of wire for air-handler shutdown
  • Lav profile design for tight installations
  • Metal mounting tabs for secure installation
  • Four inlet holes (with 3 poly covers for unused ports)
  • Float switch and duckbill-style check valve

Opsætning og installation

Proper installation is crucial for the pump's performance and longevity. Ensure all local electrical and plumbing codes are followed.

  1. Placering: Position the pump on a level surface near the HVACR unit. The low-profile design is ideal for tight spaces. Utilize the vibration dampening feet and metal mounting tabs for secure placement.
  2. Condensate Inlet Connection: Connect the condensate drain line from the HVACR unit to one of the pump's inlet holes. The pump has four inlet holes; seal any unused inlets with the provided poly covers.
  3. Tilslutning af udløbsledning: Connect the 20 ft clear vinyl tubing to the pump's discharge outlet. Route the tubing upwards, ensuring it does not exceed the pump's 22 ft vertical lift capability, and then to a suitable drain point. Avoid kinks or sharp bends in the tubing. The integrated duckbill-style check valve prevents backflow.
  4. Elektrisk tilslutning: Connect the pump to a dedicated 110V power supply. Ensure the power source is off before making connections.
  5. Sikkerhedsafbrydertilslutning: Connect the 4 ft safety switch wire (pigtail) to the air-handler's shutdown circuit. This feature is designed to shut down the HVACR unit if the pump fails or the water level rises too high, preventing overflow. Refer to your HVACR unit's manual for specific wiring instructions for the safety switch.
  6. Test: After installation, manually pour water into the pump's reservoir to verify proper operation. The pump should activate, discharge the water, and then shut off. Check for any leaks.

Betjeningsvejledning

The Asurity CP-22LPT condensate pump operates automatically once properly installed and powered.

  • When condensate water enters the pump's reservoir and reaches a predetermined level, the internal float switch activates the pump.
  • The pump will then discharge the water through the connected vinyl tubing to the designated drain.
  • Once the water level drops, the float switch deactivates the pump.
  • LED-indikatorer:
    • Pwr (Power): Illuminates when the pump is receiving electrical power.
    • Løbe: Illuminates when the pump motor is actively discharging water.
    • Alrm (Alarm): Illuminates if the water level rises to the high-level alarm switch, indicating a potential issue and activating the safety shutdown circuit.

Opretholdelse

Regelmæssig vedligeholdelse sikrer optimal ydeevne og forlænger levetiden for din kondensatpumpe.

  • Månedlig inspektion: Check the pump reservoir for sludge, mold, or debris. Clean as necessary.
  • Rensning: Disconnect power before cleaning. Remove the pump cover and clean the reservoir with a mild detergent and water. Ensure the float switch moves freely.
  • Udløbsledning: Inspect the vinyl tubing for blockages, kinks, or leaks. Clear any obstructions.
  • Inlet Ports: Ensure inlet ports are clear of debris.

Fejlfinding

Se følgende tabel for almindelige problemer og deres løsninger.

Problem Mulig årsag Løsning
Pumpen kører ikke No power; Clogged inlet/outlet; Stuck float switch; Motor failure Check power supply; Clear blockages; Inspect/clean float switch; Contact support if motor fails
Pumpen kører kontinuerligt Stuck float switch; Leak in discharge line; Pump undersized for flow rate Inspect/clean float switch; Check for leaks; Verify pump capacity meets demand
Water overflow / Alarm LED on Pump failure; Clogged discharge line; Safety switch activated Check pump operation; Clear discharge line; Investigate cause of high water level
Overdreven støj/vibration Debris in pump; Improper mounting; Worn motor bearings Clean pump; Ensure secure mounting; Contact support for motor issues

Specifikationer

Feature Detalje
Mærke Diversitech (Asurity)
Modelnummer CP-22LPT
Voltage 110 volt
Strømkilde Elektrisk med ledning
Maksimal løft 22 fod
Maksimal flowhastighed 1.6 gallon pr. Minut
Produktdimensioner 12 cm L x 6.75 cm B x 6 cm H
Varens vægt 5.41 pund
Materiale Plast
Farve Rød Sort
Inkluderede komponenter Condensate Pump, 20ft clear vinyl tubing, 4ft safety switch wire (pigtail)
Certificeringer UL-listet

Garanti og support

For warranty information or technical support, please contact Diversitech customer service. Keep your purchase receipt for warranty claims.

Fabrikant: Diversitech

Webwebsted: www.diversitech.com

Kontakte: Se producentens webhjemmeside for aktuelle kontaktoplysninger.