SUSWE SU800

SUSWE SU800 Series Variable Frequency Drive User Manual

Models: 4KW, 5.5KW, 7.5KW | Input Voltage: 220V / 380V

1. Introduktion

The SUSWE SU800 Series Variable Frequency Drive (VFD) is designed to control the speed of three-phase AC motors by varying the frequency and voltage of the power supplied to the motor. This device offers precise speed regulation, energy efficiency, and enhanced motor protection for various industrial and commercial applications. This manual provides essential information for the safe and effective installation, operation, and maintenance of your SU800 VFD.

2. Vigtige sikkerhedsinstruktioner

WARNING: Failure to follow these safety instructions may result in serious injury, death, or equipment damage.

  • Fare for elektrisk stød: Denne enhed fungerer med høj lydstyrketages. Only qualified personnel should perform installation, wiring, and maintenance.
  • Strømafbrydelse: Always disconnect all power sources to the VFD and wait at least 5 minutes for the capacitors to discharge before performing any work on the unit. The display on the VFD indicates a warning for dangerous voltages and discharge time.
  • Korrekt jording: Ensure the VFD and the motor are properly grounded according to local electrical codes.
  • Miljøforhold: Do not operate the VFD in environments with excessive dust, moisture, corrosive gases, or direct sunlight.
  • Komponentintegritet: Do not operate the VFD if any components are damaged or missing.
Front view of the SUSWE SU800 VFD showing display, control buttons, and safety warning labels.

The image displays the front panel of the SUSWE SU800 VFD, highlighting the digital display, control buttons, and prominent safety warnings regarding dangerous voltagog udladningstider.

3. Produktet er slutview

The SUSWE SU800 VFD is designed for robust performance and ease of use. It features a clear digital display, intuitive control buttons, and efficient cooling.

3.1 Kontrol og display på frontpanelet

The front panel provides real-time operational data and allows for parameter adjustments. The digital display shows key information such as output frequency (Hz), current (A), and voltage (V).

Detaljeret view of the SUSWE SU800 VFD front panel, highlighting the digital display and control buttons.

This image provides a close-up of the VFD's control panel, showing the digital readout for frequency (Hz), current (A), and voltage (V), along with the RUN, STOP/RST, PRG, MFK, ENTER, and navigation buttons.

  • Digital skærm: Shows operational parameters like frequency, current, and voltage.
  • RUN-knap: Starter motordrift.
  • STOP/RST Button: Stops motor operation and resets fault conditions.
  • PRG-knap: Enters/exits parameter programming mode.
  • MFK Button: Multi-function key, often used for quick access or specific functions.
  • ENTER knap: Confirms parameter selections or values.
  • Arrow Buttons (▲ ▼ < >): Bruges til at navigere i menuer og justere parameterværdier.

3.2 Kølesystem

The VFD incorporates an integrated cooling fan to ensure optimal operating temperatures and prevent overheating, which is crucial for maintaining performance and extending the lifespan of the unit.

Side view of the SUSWE SU800 VFD showing the integrated cooling fan.

The image illustrates the side of the VFD, focusing on the cooling fan designed to dissipate heat and maintain optimal operating temperatures.

3.3 Tilgængelige modeller

The SU800 series is available in various power ratings and input voltage configurations to suit different application requirements.

Three SUSWE VFD units of varying sizes, illustrating different power capacities within the SU800 series.

This image displays three different physical sizes of the SUSWE VFD, representing the range of power capacities available in the SU800 series, such as 4KW, 5.5KW, and 7.5KW models.

4. Tekniske specifikationer

ParameterVærdi
Model serieSU800
Input bindtage220V / 380V (3-Phase)
Udgangseffektområde4KW, 5.5KW, 7.5KW
Udgangstype3-faset
KontrolmetodeV/F-styring, vektorstyring
KommunikationsgrænsefladeRS485
FabrikantUOFKIPBA

5. Installationsvejledning

5.1 Montering

Mount the VFD vertically on a flat, stable surface. Ensure adequate clearance (at least 10 cm) around the unit for proper ventilation and heat dissipation, especially above and below the cooling fan.

5.2 Ledningsforbindelser

All wiring must be performed by a qualified electrician in accordance with local and national electrical codes. Ensure power is disconnected before making any connections.

  • Strømtilførsel (R, S, T): Connect the three-phase AC power supply to these terminals.
  • Motoreffekt (U, V, W): Connect the three-phase motor leads to these terminals.
  • Jord (PE): Connect the protective earth ground to the PE terminal.
  • Control Terminals (PB, P, B, V, U, W): These terminals are for external control signals, such as start/stop commands, speed reference, and fault outputs. Refer to the detailed wiring diagram for specific functions.
  • RS485 kommunikation: Connect the RS485 communication lines for remote control and monitoring, if applicable.
Indre view of the SUSWE SU800 VFD showing terminal blocks for power input, motor output, and control signals.

Dette billede giver en detaljeret view of the VFD's internal wiring and terminal blocks, clearly labeled for power input (R, S, T), motor output (U, V, W), ground (PE), and control connections (PB, P, B, V, U, W).

SUSWE SU800 VFD connected to a remote control panel via an Ethernet-style cable.

The image shows the main VFD unit connected to a separate remote control panel using a blue Ethernet-style cable, demonstrating the capability for external operation and monitoring.

6. Betjeningsvejledning

6.1 Grundlæggende betjening

  1. Tænd: After ensuring all connections are secure, apply power to the VFD. The display will illuminate.
  2. Indstil frekvens: Use the arrow buttons (▲ ▼) to adjust the desired output frequency (motor speed).
  3. Startmotor: Tryk på LØBE button to start the motor. The display will show the actual output frequency.
  4. Stop motoren: Tryk på STOP/RST knappen for at stoppe motoren.

6.2 Vis information

The VFD's display provides real-time feedback on the motor's operation:

  • hz: Indicates the output frequency to the motor.
  • A: Displays the motor's current consumption.
  • V: Viser udgangsvolumentage til motoren.

6.3 Parameterindstilling

To access and modify advanced parameters:

  1. Tryk på PRG button to enter the parameter menu.
  2. Use the arrow buttons (▲ ▼) to navigate through parameter groups and individual parameters.
  3. Trykke ENTER to select a parameter or view its current value.
  4. Use the arrow buttons (▲ ▼) to adjust the parameter value.
  5. Trykke ENTER igen for at gemme den nye værdi.
  6. Trykke PRG for at afslutte parametermenuen.

7. Vedligeholdelse og pleje

Regelmæssig vedligeholdelse sikrer din VFD's lange levetid og pålidelige drift.

  • Rensning: Periodically clean the VFD's exterior and ventilation openings to prevent dust accumulation, which can impede cooling. Use a soft, dry cloth. Do not use liquid cleaners.
  • Ventilation: Ensure that the VFD's cooling fan and vents are not obstructed. Proper airflow is critical for heat dissipation.
  • Terminalforbindelser: Periodically check all terminal connections for tightness. Loose connections can cause overheating and intermittent operation.
  • Miljø: Maintain the VFD in a clean, dry environment, free from excessive vibration, moisture, and corrosive substances.

8. Fejlfindingsvejledning

This section provides solutions to common issues you might encounter with your VFD. For problems not listed here, contact customer support.

ProblemMulig årsagLøsning
VFD display is off / No powerIngen indgangsstrøm; Sprunget sikring; Løse ledninger.Check input power supply; Inspect fuses; Verify all power connections are secure.
Motor kører ikkeIncorrect wiring; VFD in STOP mode; Fault condition; Incorrect frequency setting.Verify motor wiring (U, V, W); Press RUN button; Check for fault codes on display and reset; Adjust frequency setting.
Overcurrent / Overload faultMotor overloaded; Short circuit in motor/cables; Acceleration time too short.Reduce motor load; Check motor and cables for damage; Increase acceleration time parameter.
Overvoltage / Undervoltage fejlInput voltage too high/low; Regenerative braking issue.Verify input power supply voltage; Consider adding a braking resistor if regenerative loads are present.
Communication error (RS485)Incorrect wiring; Incorrect communication parameters; Device address conflict.Check RS485 wiring (A/B lines); Verify baud rate and protocol settings; Ensure unique device addresses.

9. Garanti og kundesupport

For warranty information, technical assistance, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase for any warranty claims.

© 2023 SUSWE. All rights reserved.