Akicon 110CFM 2.0Sones

Akicon Bathroom Exhaust Fan with Light

Model: 110CFM 2.0Sones

1. Vigtige sikkerhedsoplysninger

Read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power at the service panel before wiring or servicing the unit. Ensure the main power breaker is OFF.
  • All electrical wiring must be performed by a qualified electrician in accordance with all applicable local codes and standards, including fire-rated construction codes and standards.
  • Denne enhed er kun beregnet til generel ventilation. Må ikke anvendes til udsugning af farlige eller eksplosive materialer og dampe.
  • To reduce the risk of fire or electrical shock, do not expose the fan to water or moisture.
  • Never put your hands or other objects into the fan while it is operating.
  • Ensure the installation location provides adequate space for the fan housing and proper ventilation.

ADVARSEL: For at reducere risikoen for brand, elektrisk stød eller personskade, skal du være opmærksom på følgende:

  • Brug kun denne enhed på den måde, som producenten har tiltænkt. Kontakt producenten, hvis du har spørgsmål.
  • Før du servicerer eller rengør enheden, skal du slukke for strømmen på servicepanelet og låse serviceafbryderen for at forhindre strømmen i at blive tændt ved et uheld. Når serviceafbrydelsesmidlet ikke kan låses, skal du fastgøre en fremtrædende advarselsanordning, såsom en tag, til servicepanelet.

2. Produktet er slutview

The Akicon Bathroom Exhaust Fan with Light provides efficient ventilation, adjustable LED lighting, and a nightlight function, all controlled by a smart humidity sensor switch. It is designed to effectively remove moisture and odors from bathrooms, ensuring a fresh and healthy environment.

Akicon Bathroom Exhaust Fan with Light, Black, Round

Image: Akicon Bathroom Exhaust Fan with Light (Black, Round)

3. Specifikationer

FeatureSpecifikation
Luftmængde110 CFM
Støjniveau2.0 soner
LED lys strøm15W
LED lys farvetemperatur2700K / 4000K / 5500K (Justerbar)
Nightlight Output150lm (Yellow and Blue options)
Lumen Output (Main Light)1000 lm
Voltage120V
Strømforbrug (ventilator)31W
Boligmål7.5 cm (L) x 7.25 cm (B) x 5.75 cm (H)
Loftsåbning7-1/2" (L) x 7-1/4" (W)
Light Cover DimensionØ13-1/2"
KanaldiameterØ4"
InstallationstypeCeiling Mount (Wall-mounted in description, but images and video show ceiling. Assuming ceiling mount is primary.)
CertificeringerHVI, cETL, Energy Star Listed
MaterialeMetal, Plast

This fan is suitable for rooms up to 100 sq. ft.

Diagram showing fan dimensions and room coverage up to 100 square feet

Image: Fan dimensions and room coverage

4. Installation

Proper installation is crucial for the safe and efficient operation of your exhaust fan. Please follow these steps carefully. If you are unsure about any part of the installation, consult a qualified electrician.

4.1 Trin før installation

  • Afbryd strømmen: Before beginning any work, ensure the power supply to the installation area is turned off at the circuit breaker.
  • Forbered åbning: Cut an exact opening in your ceiling. The recommended opening size is 7-1/2" (L) x 7-1/4" (W). Use the fan housing to mark the precise location.

4.2 Installation Procedure (Attic Access)

If you have attic access, follow these steps:

  • Sikker bolig: Screw the fan housing into the ceiling joist.
  • Tilslut kanalarbejde: Attach the duct to the connector on the fan housing using HVAC tape to ensure a secure and airtight seal.
  • Elektriske forbindelser: Connect all electrical wiring according to local codes.

4.3 Installation Procedure (No Attic Access)

If you do not have attic access, follow these steps:

  • Remove Motor Unit: Unscrew and remove the motor unit from inside the fan housing using a Phillips screwdriver.
  • Tilslut kanalarbejde: Connect the vent duct to the ceiling opening.
  • Elektriske forbindelser: Connect all electrical wiring.
  • Indsæt hus: Hold the housing up and slide it into the ceiling opening. The integrated clips will help level the housing.
  • Sikker bolig: Drive screws into the ceiling joists to secure the housing firmly.
  • Reinstall Motor Unit: Install the motor unit back into the housing and plug it into the receptacle.
  • Connect Light/Nightlight: Plug the light and nightlight connectors into their respective receptacles.
  • Fastgør gitter: Squeeze the springs on the grille cover and gently push the grille into place until it is flush with the ceiling.

4.4 Installationsvideoguide

Video: Official installation guide for the Akicon Bathroom Exhaust Fan with Light, Model 110CFM 2.0Sones. This video demonstrates the key steps for safe and proper setup, including wiring and securing the unit.

5. Betjening

Your Akicon Bathroom Exhaust Fan features advanced controls for optimal comfort and air quality.

5.1 Humidity Sensor Control

The integrated humidity sensor automatically detects changes in room humidity levels. When humidity exceeds a preset threshold, the fan activates to remove excess moisture. Once humidity returns to normal, the fan automatically turns off.

  • Humidity Sensitivity Levels: Choose from 5 levels (90%, 80%, 70%, 60%, 50%) to customize activation.
  • Timer Intervals: Set the fan to run for 5, 15, 30, 45, or 60 minutes after activation.
  • Manuel tilsidesættelse: You can manually turn the fan on or off using the switch, overriding the humidity sensor as needed.

5.2 Dimmable LED Light and Nightlight

The fan includes a 15W dimmable LED light with adjustable color temperature and a separate nightlight function.

  • Farvetemperaturindstillinger: Cycle through 2700K (warm white), 4000K (neutral white), and 5500K (cool white) to set your preferred ambiance.
  • Nightlight Options: The integrated nightlight offers both yellow and blue color options for gentle illumination.
Three bathroom scenes showing LED light at 2700K, 4000K, and 5500K color temperatures

Image: Adjustable LED light color temperatures (2700K, 4000K, 5500K)

Diagram of the humidity sensor switch with labels for LED indicator, humidity sensor, fan switch, LED light switch, and night light switch

Image: Product features of the humidity sensor switch

6. Vedligeholdelse

Regelmæssig vedligeholdelse sikrer din udsugningsventilators levetid og optimale ydeevne.

  • Strømafbrydelse: Always turn off the power supply at the circuit breaker before performing any maintenance or cleaning.
  • Rengøring af gitter: Remove the grille cover by gently squeezing the spring clips. Wash the grille with mild soap and water, rinse thoroughly, and dry completely before reattaching.
  • Rengøring af ventilatorblade: Carefully wipe the fan blades and interior of the housing with a damp cloth to remove dust and debris. Avoid getting water into electrical components.
  • Genmontering: Once all parts are clean and dry, reassemble the fan and restore power.

7. Fejlfinding

If you encounter issues with your Akicon Bathroom Exhaust Fan, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Ventilatoren fungerer ikkeNo power supply; Loose wiring; Motor malfunctionCheck circuit breaker; Verify all wiring connections; Contact customer support if motor is faulty.
Lyset tænder ikkeLoose light connector; Faulty LED moduleEnsure light connector is securely plugged in; Contact customer support for LED replacement.
Overdreven støj under driftLoose mounting screws; Debris in fan blades; Motor issueCheck and tighten mounting screws; Clean fan blades; Contact customer support.
Poor ventilation/humidity remains highBlocked ductwork; Incorrect humidity sensor setting; Fan undersized for roomCheck ductwork for obstructions; Adjust humidity sensitivity level; Ensure fan CFM matches room size.

8. DIY Grille Style Change (3-Layer to 2-Layer)

The fan grille is designed to be customizable, allowing you to change its appearance from a three-layer to a two-layer style to better match your bathroom aesthetics.

Procedure:

  • Fjern gitter: Gently pull down the grille cover to detach it from the fan housing.
  • Adgangsskruer: On the back of the grille, locate the six long screws securing the layers.
  • Replace Screws: Remove the six long screws and replace them with the shorter screws provided in the package.
  • Reposition Spring Clips: Remove the spring clips from their current position and reinstall them onto the shorter posts (piles) to accommodate the reduced number of layers.
  • Genmonter gitteret: Once the changes are made, reattach the grille cover to the fan housing.
Diagram showing how to convert the 3-layer grille to a 2-layer grille by removing a section

Image: DIY grille style change from 3-layers to 2-layers

9. Garanti og support

For warranty information, please refer to the documentation included with your product or visit the official Akicon website. If you require technical assistance, have questions about installation, or need to report a defect, please contact Akicon customer service.

Akicon Customer Service: Refer to your product packaging or the Akicon webwebsted for kontaktoplysninger.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.