1. Introduktion

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Duluth Forge DLS-18T-1 Dual Fuel Ventless Fireplace Logs Set. Please read all instructions carefully before installation and use. Retain this manual for future reference.

Duluth Forge DLS-18T-1 Dual Fuel Ventless Fireplace Logs Set with flames

Image 1.1: The Duluth Forge DLS-18T-1 Dual Fuel Ventless Fireplace Logs Set in operation.

2. Sikkerhedsoplysninger

ADVARSEL: Forkert installation, justering, ændring, service eller vedligeholdelse kan forårsage personskade eller materielle skader. Se denne manual. For assistance eller yderligere information, kontakt en kvalificeret installatør, et servicebureau eller gasleverandøren.

  • Dette apparat er kun til indendørs brug.
  • Opbevar eller brug ikke benzin eller andre brændbare dampe og væsker i nærheden af ​​dette eller noget andet apparat.
  • The Oxygen Depletion Sensor (ODS) is a safety feature that automatically shuts off the gas supply if oxygen levels in the room fall below a safe threshold. Do not tamper with or bypass the ODS.
  • Ensure adequate ventilation as specified in local codes and this manual.
  • Minimum Firebox Size Required: 20” H x 29” W in front (22” W at rear) x 13” D.
  • Keep children and pets away from the appliance when it is in operation.

3. Produktfunktioner

  • Dobbelt brændstofteknologi: Operates with either Natural Gas or Liquid Propane.
  • Høj varmeafgivelse: 30,000 BTU, capable of heating up to 1,000 sq. ft.
  • Ventilationsfrit design: 99.9% efficient, no outside duct or chimney required.
  • Termostatstyring: Automatically cycles the burner to maintain a desired room temperature.
  • Realistiske træstammer: 8 hand-painted ceramic logs designed to emulate a split red oak wood fire.
  • Sikkerhedsforsikring: Equipped with a Safety Pilot O.D.S. (Oxygen Depletion Sensor) with automatic shut-off.
  • Nem tænding: Battery-assisted Piezo ignition (requires 1 AAA Battery, included).
Close-up of the Duluth Forge gas logs with active flames

Billede 3.1: Detaljeret view of the ceramic logs and flames.

4. Pakkens indhold

Sørg for, at alle følgende komponenter er til stede ved udpakning:

  • Gas Burner Assembly
  • 8 Hand-Painted Ceramic Logs
  • Jernrist
  • U-Burner Chassis
  • Termostat kontrolenhed
  • Oxygen Depletion Sensor (integrated)
  • 1 AAA batteri
  • Hardware pakke
Diagram showing all included components of the fireplace log set

Image 4.1: All components included in the Duluth Forge DLS-18T-1 package.

5. Installation og opsætning

Installation should be performed by a qualified professional in accordance with all local codes and the provided instructions. This appliance must be installed in a masonry or agency-approved firebox.

5.1 Kontrol før installation

  • Verify that the firebox meets the minimum size requirements: 20” H x 29” W in front (22” W at rear) x 13” D.
  • Ensure the gas supply type (Natural Gas or Liquid Propane) matches the appliance’s configuration. The patented Dual Fuel Technology allows conversion, but it must be correctly set for your gas type.
  • Confirm that the area has adequate ventilation.

5.2 Komponentplacering

  1. Carefully place the burner assembly and iron grate within the firebox.
  2. Arrange the ceramic logs according to the detailed log placement instructions provided with the hardware pack. Proper log placement is crucial for flame appearance and safe operation.
  3. Connect the gas line to the burner assembly. This step requires professional expertise.
Duluth Forge gas logs installed in a fireplace

Image 5.1: The gas log set properly installed within a fireplace.

6. Betjeningsvejledning

6.1 Initial Ignition

  1. Sørg for, at gasforsyningsventilen er åben.
  2. Insert the included AAA battery into the Piezo ignition unit.
  3. Turn the control knob to the 'Pilot' position and depress it.
  4. While holding the knob down, press the Piezo ignitor button repeatedly until the pilot flame ignites. Continue to hold the control knob down for approximately 30-60 seconds after ignition to allow the thermocouple to heat up.
  5. Release the control knob. If the pilot flame extinguishes, repeat the process.

6.2 Main Burner Operation (Thermostat Control)

The thermostat control allows you to set a desired room temperature, and the unit will automatically cycle on and off to maintain it.

  1. Once the pilot is lit, turn the control knob from 'Pilot' to the desired heat setting (1-5).
  2. The main burner will ignite, and flames will appear among the logs.
  3. To adjust the temperature, rotate the control knob to a higher or lower setting. The unit will automatically regulate the flame to reach and maintain the set temperature.
  4. To turn off the main burner while keeping the pilot lit, turn the control knob to the 'Pilot' position.
  5. To completely turn off the unit, turn the control knob to the 'Off' position and close the main gas supply valve.
Close-up of the thermostat control knob and Piezo ignitor button

Image 6.1: Thermostat control and Piezo ignition for the log set.

7. Vedligeholdelse

Regular maintenance ensures safe and efficient operation of your fireplace logs set.

  • Årlig inspektion: Have a qualified service technician inspect the burner assembly, gas connections, and logs annually.
  • Rensning: Keep the area around the appliance clear of combustible materials. Periodically clean the logs and burner area with a soft brush or vacuum cleaner to remove dust and debris. Ensure the unit is completely cool and the gas supply is off before cleaning.
  • Log Condition: Inspect logs for cracks or damage. Replace any damaged logs to maintain proper flame patterns and safety.

8. Fejlfinding

If you encounter issues, refer to the following common troubleshooting steps. For persistent problems, contact a qualified service technician.

8.1 Pilot Light Will Not Stay Lit

  • Gasforsyning: Ensure the main gas supply valve is fully open.
  • Termoelement: The thermocouple may not be heating sufficiently. Ensure the pilot flame is directly impinging on the thermocouple. Hold the control knob down for the recommended 30-60 seconds after ignition.
  • ODS Activation: The Oxygen Depletion Sensor may have activated due to low oxygen levels. Ensure adequate ventilation in the room.
  • Pilot Orifice: A clogged pilot orifice can cause a weak pilot flame. This requires professional cleaning.

8.2 Main Burner Does Not Ignite

  • Pilot Lit: Confirm the pilot light is actively burning. The main burner will not ignite if the pilot is out.
  • Control Knob Position: Ensure the control knob is turned to a numbered heat setting (1-5) and not just 'Pilot' or 'Off'.
  • Gastryk: Low gas pressure can prevent the main burner from igniting. Consult your gas supplier or a professional.

9. Specifikationer

AttributDetalje
MærkeDuluth Forge
ModelnavnDobbelt brændstof
VaremodelnummerDLS-18T-1-AZ
StrømkildeGasdrevet (naturgas eller flydende propan)
Varmeoutput30,000 britiske termiske enheder (BTU)
VarmedækningOp til 1,000 sq ft
VentilationstypeVent fri
Produktdimensioner23.5" D x 15.5" B x 18" H
Minimum brændkammerstørrelse20” H x 29” W in front (22” W at rear) x 13” D
MaterialeKeramisk
TændingstypeBattery-assisted Piezo (1 AAA Battery)
SikkerhedsfunktionerIltforbrugssensor (ODS)
Varens vægt23.9 pund (10.84 kilo)
Diagram illustrating the dimensions of the fireplace log set

Image 9.1: Key dimensions of the Duluth Forge DLS-18T-1 log set.

10. Garanti og support

For warranty information and customer support, please refer to the documentation included with your product or contact Duluth Forge directly. You can also visit the official Duluth Forge store on Amazon for more information: Duluth Forge Amazon Store.

© 2024 Duluth Forge. All rights reserved.