1. Introduktion
This manual provides detailed instructions for the installation, operation, and maintenance of the EVURU F64A 1-inch Manual Backwash Filter Valve. This multi-port control valve is designed for use with water softener systems, facilitating various functions such as service, backwash, brine intake, brine refill, and fast rinse. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the valve.
2. Sikkerhedsoplysninger
- Bær altid passende personlige værnemidler (PPE) under installation og vedligeholdelse.
- Ensure the water supply is turned off and pressure is relieved before attempting any installation or service.
- Kontroller, at alle forbindelser er sikre og fri for lækager, før vandtrykket genoprettes.
- Do not exceed the specified operating pressure or temperature limits.
- If you are unsure about any installation or maintenance procedure, consult a qualified professional.
3. Produktet er slutview
The EVURU F64A is a robust manual multi-port valve constructed from ABS/PPO, designed for efficient control of water flow in water softener systems. It features a user-friendly handle for selecting different operational modes.

Figure 1: EVURU F64A 1-inch Manual Backwash Filter Valve. This image shows the overall appearance of the valve with its chrome handle and black body, indicating a 1-inch connection size.
3.1 Valve Components and Ports

Figure 2: Detailed diagram of the EVURU F64A valve, highlighting the Handle, Outlet, Brine, Inlet, and Drain ports. The image also includes a table explaining the operational modes and their corresponding symbols.
- Håndtag: Used to manually select the desired operational mode.
- Fjord: Connection point for untreated water entering the valve.
- Outlet: Connection point for treated water exiting the valve.
- saltlage: Port for brine solution intake during regeneration.
- Dræne: Port for wastewater discharge during backwash and rinse cycles.
3.2 Driftstilstande
The valve features five distinct operational modes, selected by rotating the handle:
| Mode | Beskrivelse |
|---|---|
| SERVICE | Normal operation mode where water flows through the softener for treatment. |
| BAGSKYLNING | Reverses water flow to flush accumulated debris from the filter media to the drain. |
| BRINE & SLOWR | Draws brine solution from the brine tank into the softener tank for regeneration. |
| PÅFYLDNING AF BRINE | Refills the brine tank with water after the regeneration cycle. |
| HURTIG SKYLNING | Flushes residual brine and prepares the media for service mode. |
4. Specifikationer
| Parameter | Værdi |
|---|---|
| Model | F64A |
| Tilslutning/udtag | 1" Female NPT |
| Brine Connection | 3/8" Male |
| Afløbstilslutning | 1/2" Male |
| Central Pipe OD | 1.05" |
| Grundlag | 2.5"-8NPSM |
| Maksimal flowhastighed | 4 m³/t |
| Kompatibel tankstørrelse | 6"~18" FRP Tank |
| Arbejdstryk | 0.15 MPa ~ 0.6 MPa (150 kPa ~ 600 kPa) |
| Arbejdstemperatur | 5°C ~ 50°C |
| Materiale | Acrylonitril Butadien Styren (ABS) |
| Antal havne | 4 |
| Standarder opfyldt | ASME B16.34, ASME B16.5 |
5. Opsætning og installation
Proper installation is crucial for the efficient operation of your water softener system. It is recommended that installation be performed by a qualified plumber or technician.
5.1 Trin før installation
- Unpack the valve and inspect for any shipping damage.
- Sørg for, at alle nødvendige VVS-fittings og værktøjer er tilgængelige.
- Turn off the main water supply to the premises.
- Relieve water pressure in the system by opening a nearby faucet.
5.2 Installationsprocedure
- Klargør tanken: Ensure the central pipe (riser tube) is correctly installed in the water softener tank and extends to the appropriate height for the valve. The central pipe OD should be 1.05 inches.
- Monter ventilen: Carefully screw the valve onto the tank's top opening. The valve base is 2.5"-8NPSM. Ensure a tight, leak-free seal, using thread sealant if necessary.
- Connect Inlet/Outlet: Connect the main water supply line to the 1" Female NPT Inlet port and the treated water line to the 1" Female NPT Outlet port. Use appropriate plumbing fittings and thread sealant.
- Connect Brine Line: Connect the 3/8" Male brine line from the brine tank to the designated brine port on the valve.
- Tilslut afløbsledning: Connect a 1/2" Male drain line from the valve's drain port to an appropriate drain point, ensuring it has an air gap to prevent back-siphonage.
- Tjek for lækager: Tænd langsomt for hovedvandforsyningen, og kontroller omhyggeligt alle tilslutninger for lækager. Spænd eventuelle utætte tilslutninger efter behov.
- Indledende skylning: Before putting the system into service, perform an initial backwash and fast rinse cycle to flush out any installation debris or air.
6. Betjeningsvejledning
The EVURU F64A valve is operated manually by rotating the handle to align with the desired mode indicator. Always rotate the handle slowly and deliberately to ensure proper engagement of the internal components.
6.1 Valg af tilstand
To change the valve's operational mode:
- Tag godt fat i håndtaget.
- Rotate the handle clockwise or counter-clockwise until the indicator on the handle aligns with the desired mode label (SERVICE, BACKWASH, BRINE & SLOWR, BRINE REFILL, FAST RINSE) on the valve body.
- Ensure the handle clicks securely into place for each mode.
6.2 Regenereringscyklus (f.eks.ampdet)
A typical regeneration cycle for a water softener using this valve would involve the following sequence:
- TILBAGESKYLNING: Rotate the handle to BACKWASH. Allow water to flow to the drain for approximately 10-15 minutes, or until the drain water runs clear. This removes trapped sediment from the media.
- BRINE & SLOWR: Rotate the handle to BRINE & SLOWR. The valve will draw brine solution from the brine tank into the softener tank. This process typically takes 60-90 minutes, depending on the system size.
- BRINE REFILL: Rotate the handle to BRINE REFILL. This mode will replenish the brine tank with the correct amount of water for the next regeneration cycle. Consult your softener system's manual for specific refill volumes and times.
- HURTIG SKYLNING: Rotate the handle to FAST RINSE. This flushes residual brine from the softener media and compacts the media bed. Allow to run for 10-20 minutes, or until the water tastes free of salt.
- SERVICE: Rotate the handle to SERVICE. The softener is now ready to provide treated water.
7. Vedligeholdelse
Regular maintenance ensures the optimal performance and extends the lifespan of your EVURU F64A valve.
- Visuel inspektion: Periodically inspect the valve for any signs of leaks, cracks, or damage. Check all connections for tightness.
- Renhed: Keep the exterior of the valve clean. Avoid using harsh chemicals that could damage the ABS/PPO material.
- Håndtagsbetjening: Ensure the handle rotates smoothly and clicks positively into each position. If it becomes stiff, it may indicate internal wear or debris.
- O-rings and Seals: Over time, O-rings and seals may wear out. If leaks occur around the handle or ports, these components may need to be replaced. Consult a professional for internal seal replacement.
- Afløbsledning: Ensure the drain line remains clear and free of obstructions.
8. Fejlfinding
This section addresses common issues you might encounter with the EVURU F64A valve.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Water leaking from valve connections | Loose fittings, damaged O-rings/seals, improper thread sealant. | Turn off water supply, tighten connections, inspect and replace O-rings/seals if damaged, reapply thread sealant. |
| Valve handle is stiff or hard to turn | Internal debris, worn internal components, mineral buildup. | Turn off water supply, relieve pressure. Attempt to gently work the handle. If persistent, internal inspection by a professional may be required. |
| No water flow in SERVICE mode | Valve not fully in SERVICE position, main water supply off, clogged filter media. | Ensure handle is correctly aligned. Check main water supply. Perform a BACKWASH cycle to clear media. |
| Water continuously flowing to drain | Valve stuck in BACKWASH or RINSE mode, internal seal failure. | Ensure handle is correctly aligned to SERVICE. If issue persists, internal valve inspection and seal replacement may be necessary. |
| Brine tank not drawing brine | Brine line clogged, injector clogged, air leak in brine line, valve not in BRINE & SLOWR mode. | Check brine line for kinks or blockages. Clean the injector. Ensure all brine line connections are tight. Verify valve is in BRINE & SLOWR mode. |
9. Garanti og support
Warranty information for the EVURU F64A Manual Backwash Filter Valve is typically provided with the product packaging or can be obtained directly from your point of purchase or the manufacturer. Please retain your proof of purchase for warranty claims.
For technical support, spare parts, or further assistance, please contact your product supplier or the EVURU customer service department. Contact details are usually available on the product packaging or the manufacturer's official webwebsted.